Search PubMed⌕ Search

Biomedical subjects

C Capelle

Publications and source records attributed to C Capelle.

9 recordsLinked to original sources

Auditory coding of visual patterns for the blind.

Recognition tasks of simple visual patterns have been used to assess an early visual--auditory sensory-substitution system, consisting of the coupling of a rough model of the human retina with an inverse model of the cochlea, by means of a pixel-frequency relationship. The potential advantage of the device, compared with previous ones, is to give the blind the ability to both localise and recognise visual patterns. Four evaluation sessions assessed the performance of twenty-four blindfolded sighted subjects using the device. Subjects had to recognise twenty-five visual patterns, one at a time, using a head-mounted small camera and interpreting the corresponding sounds given by the device. Half the subjects were trained by means of a correction feedback procedure during ten one-hour training sessions embedded in between the evaluation sessions. Results revealed extremely successful training effects. Performance of trained subjects significantly increased with practice compared with the untrained control group. The improvement was also observed for new patterns, demonstrating a learning-process generalisation. The negative correlation observed between scores and processing time showed that the subjects' response accuracy was related to their speed. In conclusion, simple pattern recognition is possible with a fairly natural vision-to-audition coding scheme, given the possibility for the subjects to have sensory--motor interactions while using the device.

Adult↗

A real-time experimental prototype for enhancement of vision rehabilitation using auditory substitution.

The rehabilitation of blindness, using noninvasive methods, requires sensory substitution. A theoretical frame for sensory substitution has been proposed which consists of a model of the deprived sensory system connected to an inverse model of the substitutive sensory system. This paper addresses the feasibility of this conceptual model in the case of auditory substitution, and its implementation as a rough model of the retina connected to an inverse linear model of the cochlea. We have developed an experimental prototype. It aims at allowing optimization of the sensory substitution process. This prototype is based on a personal computer which is connected to a miniature head-fixed video camera and to headphones. A visual scene is captured. Image processing achieves edge detection and graded resolution. Each picture element (pixel) of the processed image is assigned a sinusoidal tone; weighted summation of these sinewaves builds up a complex auditory signal which is transduced by the headphones. On-line selection of various parameters and real-time functioning of the device allow optimization of parameters during psychophysical experimentations. Assessment of this implementation has been initiated, and has so far demonstrated prototype usefulness for pattern recognition. An integrated circuit of this system is to be developed.

Adaptation, Physiological↗

Standardization of platelet counts--problems and pitfalls.

In a previous work, we have compared two automated techniques for platelet-rich plasma using a thrombocounter or whole blood with the continuous flow instrument Auto-analyzer (AA). More recently, we have tested two instruments using whole blood: the first one, fully automated: Coulter S+; and the other one, semi-automated: Clay-Adams. In the present work, these 4 methods are compared to the phase contrast microscope technique, used as reference. The coefficients of variation ranged between 2 and 13 per cent. The coefficients of correlation between the different methods were between 0.92 and 0.96. Platelet distribution curves for platelet volumes obtained in parallel with platelet-rich plasma and with whole blood in 30 controls, show that platelet population are not significantly different. These instruments count particles and, therefore, necessitate a calibration made by means of platelet standards. Different platelet standards have been studied: these containing latex particles seem to give better results than suspensions of human or animal platelets.

Blood Platelets↗