Search PubMed⌕ Search

Biomedical subjects

C C Anderson

Publications and source records attributed to C C Anderson.

48 records · Page 3Linked to original sources

Acute respiratory failure: an approach to diagnosis and management.

Acute respiratory failure can be diagnosed using clinical judgment and simple bedside measurement of physiologic function. Respiratory support is based on the pathophysiology of the disorder. Initial therapy is directed at correcting life-threatening hypercapnia, hypoxia, and acidosis. The final outcome is positively influenced by skillful intensive care and a team approach.

Acute Disease↗

Closed reduction and lag screw fixation of sacroiliac luxations and fractures.

OBJECTIVE: To describe a technique for closed reduction and percutaneous insertion of a lag screw for fixation of sacroiliac fracture-luxations, and to report the success of this technique in stabilizing sacroiliac fracture-luxations. STUDY DESIGN: A retrospective clinical study. STUDY POPULATION: 13 consecutive client-owned dogs with sacroiliac fracture-luxations. METHODS: Sacroiliac fracture-luxations were stabilized by using a closed reduction and percutaneous lag screw fixation technique. Preoperative, postoperative, and last re-examination radiographs were used to assess the location and number of pelvic injuries, other orthopedic injuries, percent reduction of the sacroiliac joint, percent sacral width screw depth, position of the screw, pelvic canal diameter ratio, hemipelvic canal width ratio, and complications. Information on signalment, weight, weight-bearing status, neurologic status, and complications was obtained from the medical record. RESULTS: Mean percent reduction of the sacroiliac joint was 92.33%. All screws were placed within the sacral body with a mean screw depth/sacral width of 79.03%. No screw loosening occurred. Mean pelvic canal diameter ratios were 0.99, 1.20, and 1.14 preoperatively, immediately postoperatively, and at the last re-examination, respectively. Nine of 13 dogs were willing to walk on the ipsilateral rear leg the day after surgery. CONCLUSIONS: Closed reduction and percutaneous insertion of a lag screw for stabilization of fracture-luxation of the sacroiliac joint is an acceptable method of repair. CLINICAL RELEVANCE: Sacroiliac fracture-luxations can be successfully reduced and stabilized using a minimally invasive technique.

Animals↗

Biomechanical evaluation of a crimp clamp system for loop fixation of monofilament nylon leader material used for stabilization of the canine stifle joint.

OBJECTIVE: To test a crimp clamp system designed to secure monofilament nylon leader (MNL) material commonly used as lateral fabellotibial sutures (LFS) in extra-articular stabilization of the canine stifle joint. STUDY DESIGN: In vitro biomechanical tests of MNL loops secured with either the crimp clamp system or knots were performed. Suture loops (n = 94) were created from 27.3 kg tensile strength MNL and fastened with knots or crimp clamps. Tests were conducted on steam-sterilized, ethylene-oxide-sterilized, and nonsterilized MNL sutures. Loops were evaluated in single load tests and cycled tests. Values for load to failure, initial loop tension, loop elongation, mode of failure, and point of failure were determined. RESULTS: Crimp-clamped loops were superior to knotted loops in all parameters tested in both cycled and noncycled tests. Loop failure generally occurred by breaking within 3 mm of the fixation in both clamped and knotted tests. Loop elongation after cycling was greater in the knotted loops compared with clamped loops (P < .001). Load to failure was greater in clamped tests than in knotted tests (P < .001), regardless of sterilization technique used. Significantly higher initial loop tension could be achieved with the clamp system compared with knot fixation (P < .001). CONCLUSIONS: The crimp clamp system provides superior in vitro loop fixation characteristics compared with knot fixation in 27.3 kg test MNL. CLINICAL RELEVANCE: Based on the results of biomechanical testing and the known biocompatibility of the system's implant components, clinical trials using the crimp clamp system are warranted.

Animals↗