Search PubMed⌕ Search

Biomedical subjects

C Burman

Publications and source records attributed to C Burman.

27 records · Page 2Linked to original sources

Three-dimensional photon treatment planning for carcinoma of the nasopharynx.

The role of 3-D treatment planning for carcinoma of the nasopharynx was assessed in a four institution study. Two patients were worked up and had an extensive number of CT scans on which target volumes and normal tissues were defined. Treatment planning was then performed using state of the art dose planning systems for these patients to assess the value of the new technology. In general, it was demonstrated that multi-field conformal plans could achieve good tumor dose coverage, while at the same time reducing normal tissue doses, compared to standard treatment planning techniques. The role of inhomogeneity corrections, beam energy, and the use of CT vs. simulation films for defining target volumes were also discussed. In addition, techniques to evaluate 3-D plans for the nasopharynx were considered, and some analysis of this problem is presented in this paper.

Adult↗

Three-dimensional treatment planning for para-aortic node irradiation in patients with cervical cancer.

Three-dimensional treatment planning has been used by four cooperating centers to prepare and analyze multiple treatment plans on two cervix cancer patients. One patient had biopsy-proven and CT-demonstrable metastasis to the para-aortic nodes, while the other was at high risk for metastatic involvement of para-aortic nodes. Volume dose distributions were analyzed, and an attempt was made to define the role of 3-D treatment planning to the para-aortic region, where moderate to high doses (50-66 Gy) are required to sterilize microscopic and gross metastasis. Plans were prepared using the 3-D capabilities for tailoring fields to the target volumes, but using standard field arrangements (3-D standard), and with full utilization of the 3-D capabilities (3-D unconstrained). In some but not all 3-D unconstrained plans, higher doses were delivered to the large nodal volume and to the volume containing gross nodal disease than in plans analyzed but not prepared with full 3-D capability (3-D standard). The small bowel was the major dose limiting organ. Its tolerance would have been exceeded in all plans which prescribed 66 Gy to the gross nodal mass, although some reduction in small bowel near-maximum dose was achieved in the 3-D unconstrained plans. All plans were able to limit doses to other normal organs to tolerance levels or less, with significant reductions seen in doses to spinal cord, kidneys, and large bowel in the 3-D unconstrained plans, as compared to the 3-D standard plans. A high probability of small bowel injury was detected in one of four 3-D standard plans prescribed to receive 50 Gy to the large para-aortic nodal volume; the small bowel dose was reduced to an acceptable level in the corresponding 3-D unconstrained plan. An optimum beam energy for treating this site was not identified, with plans using 4, 6, 10, 15, 18, and 25 MV photons all being equally acceptable. Attempts to deliver moderate or high doses (50-66 Gy) to this region should be made only after careful analysis of the plan with techniques similar to those employed in this study.

Aged↗

Three-dimensional treatment planning considerations for prostate cancer.

Over 300 treatment plans for a total of eight disease sites based on 3-D treatment planning considerations utilizing serial CT delineated target volumes were generated by four institutions as part of an NCI supported contract to both assess the current state-of-the-art capabilities and point directions for future efforts. Two patients with stage C prostate cancer were evaluated with protocol plans which required treatment of the prostate to 70 Gy and the pelvic lymph nodes to 46 Gy. When full 3-D target definition and multiple beam arrangements were employed, all institutions were able to submit plans which scored higher on tumor coverage and had lower normal tissue complication scores compared to traditional plans. The 3-D plans using standard beam arrangements, however, were often rated as highly as the 3-D unconstrained plans due to the multiple beam arrangements already selected to optimize standard plans at most institutions. For this site, heterogeneity corrections, beam energy changes and changes in CT number did not substantially change plan scores.

Aged↗

Three-dimensional treatment planning for postoperative treatment of rectal carcinoma.

The role of three-dimensional (3-D) treatment planning for postoperative radiation therapy was evaluated for rectal carcinoma as part of an NCI contract awarded to four institutions. It was found that the most important contribution of 3-D planning for this site was the ability to plan and localize target and normal tissues at all levels of the treatment volume, rather than using the traditional method of planning with only a single central transverse slice and simulation films. There was also a slight additional improvement when there were no constraints on the types of plans (i.e., when noncoplanar beams were used). Inhomogeneity considerations were not important at this site under the conditions of planning, i.e., with energies greater than 4 MV and multiple fields. Higher beam energies (15-25 MV) were preferred by a small margin over lower energies (down to 4 MV). The beam's eye view and dose-volume histograms were found quite useful as planning tools, but it was clear that work should continue on better 3-D displays and improved means of translating such plans to the treatment area.

Combined Modality Therapy↗

Compensation in three-dimensional non-coplanar treatment planning.

This paper presents a technique for producing uniform dose distributions within the target volume with non-coplanar field arrangements. The method is based upon the principle used for producing homogeneous dose distributions for a pair of fields in two dimensions, namely, that if the isodose distributions for the fields are made parallel to one another, the combined dose distribution will be uniform. For the three-dimensional non-coplanar case, homogeneous target dose distributions are obtained by designing field modifiers which produce a uniform dose distribution on the perpendicular bisector plane for each pair of fields. It is demonstrated that for three non-coplanar fields irradiating a spherical phantom with spherical target volumes, the target dose distribution will be homogeneous for any arbitrary non-coplanar field arrangement. Furthermore, this technique can be extended to any number of fields. Therefore, target dose distributions for non-coplanar plans can be as homogeneous as the coplanar case. An example of the application of the method to the treatment of rectal carcinoma with non-coplanar fields is given. Furthermore, it is demonstrated that the therapeutic ratio is improved over traditional methods for this clinical example.

Humans↗

Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method.

An estimation of normal tissue complication probability factors is important, particularly for evaluating 3-dimensional treatment plans. A method has been developed to calculate complication probability factors for non-uniformly irradiated normal organs using dose volume histograms and complication probabilities for uniform partial organ irradiation. In the effective volume method each volume element of the histogram is considered independently and subject to a power law dose volume relationship. Thus, a non-uniform dose volume histogram is reduced to a uniform one with an effective volume, and a dose equal to the maximum dose to the organ. The complication probability is then obtained from known complication probabilities for uniform partial organ irradiation. The effective volume histogram transformation method is shown to obey various boundary conditions, and is illustrated by comparing probability calculations for alternative 3-dimensional treatment plans for the pelvis. In addition, the limitations of this histogram reduction method are discussed and compared to other calculational techniques. The use of probability factor calculations in treatment plan evaluation, and their role in numerical scoring is explored.

Humans↗

The role of metoclopramide in acute and delayed chemotherapy induced emesis: a randomised double blind trial.

High dose metoclopramide is an effective anti-emetic for use with cisplatin containing chemotherapy regimens but can cause extrapyramidal reactions. Lorazepam and dexamethasone are increasingly being used to alleviate chemotherapy induced emesis. This trial has assessed the contribution of high dose metoclopramide to anti-emetic control when given with dexamethasone and lorazepam. Eight-one patients receiving chemotherapy, mainly for gynaecological malignancy, entered a randomised double blind cross-over trial comparing dexamethasone and lorazepam with or without a 24 h metoclopramide infusion. This was followed by oral dexamethasone with or without oral metoclopramide for three further days depending on the initial randomisation. Sixty-one patients were fully evaluable. Fifty-five received cisplatin containing regimens and six non-cisplatin regimens. There was a significant reduction in the number of episodes of vomiting during the first 24 h in patients receiving the metoclopramide combination (P = 0.0001). On first exposure to chemotherapy 45% of patients receiving dexamethasone, lorazepam and high dose metoclopramide had no vomiting while 67% had two episodes or less ('major control'). This compared to 11% total control and 25% major control in those receiving dexamethasone, lorazepam and placebo. The control of nausea in the first 24 h was also improved (P = 0.0001). There was no difference in the degree of nausea or vomiting during the following three weeks between those receiving oral dexamethasone alone and those receiving dexamethasone and metoclopramide. Both groups showed a significant increase in nausea in the three weeks following the second course of treatment when compared to the first (P = 0.0007). Extrapyramidal reactions were recorded in 11.5% of patients receiving metoclopramide. More patients stated a preference for the metoclopramide combination although this was not statistically significant (chi 2(1) = 0.29, P = 0.59). In conclusion the combination of dexamethasone and lorazepam can give major control of emesis in 25% of patients receiving very emetogenic chemotherapy. The addition of metoclopramide increases this to 67% on first exposure to chemotherapy, but at the expense of extrapyramidal reactions in 11.5%.

Adult↗

Compensators for three-dimensional treatment planning.

Presented here is a method of designing compensators for a single beam or one or more pairs of beams, not necessarily parallel opposed. The objective is to produce a flat distribution in a plane that may be perpendicular to the central ray or may be an arbitrarily oriented plane, for example, a plane that bisects the hinge angle between two beams. The method takes into account not only surface irregularities but also tissue inhomogeneities, hinge angles between beams, distance from the source, and even "horns" in the beam. The design process employs convolution of Monte Carlo generated pencil beams with photon fluence distributions, appropriately modified for the presence of beam modifiers (blocks and compensators), to compute dose in a flat homogeneous phantom. Corrections for inhomogeneities and surface curvature are applied by using computerized tomography information to determine the effective path length through tissue. Multiple interactions are used to arrive at a compensator that properly incorporates changes in radiation transport, and therefore dose distribution, resulting from the presence of beam-shaping devices. In each iteration it is assumed that the required reduction in dose at a point can be achieved by reducing the fluence along the ray joining the source to computation point proportionately. The compensator design is represented as a finely spaced matrix of thickness values which is entered into a prorammable milling maching for fabrication. Dose measurements in phantom exposed to 6-MV x rays with and without compensation are presented.

Equipment Design↗

Final report of the 70.2-Gy and 75.6-Gy dose levels of a phase I dose escalation study using three-dimensional conformal radiotherapy in the treatment of inoperable non-small cell lung cancer.

PURPOSE AND OBJECTIVE: Three-dimensional conformal radiotherapy (3D-CRT) is a mode of high-precision radiotherapy designed to increase the tumor dose and decrease the dose to normal tissues. This study reports the final results of the first two dose levels (70.2 Gy and 75.6 Gy) of a phase I dose-escalation study using 3D-CRT for the treatment of non-small cell lung cancer. PATIENTS AND METHODS: Fifty-two patients were treated with 3D-CRT without chemotherapy. The median age was 67 years (range, 39-82 years). The majority of patients had locally advanced cancer. Tumor was staged as I/II in 10%, IIIA in 40%, and IIIB in 50%. Radiation was delivered in daily fractions of 1.8 Gy, 5 days a week. A radiation dose level was considered complete when 10 patients received the intended dose without unacceptable acute morbidity. Toxicity was scored according to the Radiation Therapy Oncology Group grading scheme. RESULTS: Twenty patients were initially assigned to the 70.2-Gy level; 14 of them received the intended dose. Three patients experienced severe acute toxicity, two with grade 3 (requiring steroids or oxygen) and a third with grade 5 (fatal) acute radiation pneumonitis. Because of the grade 5 pulmonary toxicity, the protocol was modified, and only patients with a calculated risk of normal tissue complication of less than 25% were eligible for dose escalation. Patients who had a normal tissue complication probability (NTCP) of greater than 25% received a lower dose of radiation. An additional 18 patients were entered on the modified study; 11 of them received 70.2 Gy. One patient experienced grade 3 acute pneumonitis. Despite dose reduction in four patients because of an unacceptably high NTCP, two additional patients developed grade 3 pulmonary toxicity. Fourteen patients were accrued to the 75.6-Gy dose level, and 10 received the intended dose. One of the 10 patients experienced grade 3 pulmonary toxicity and one developed grade 3 esophageal toxicity. Three patients were treated to lower doses as a result of their calculated NTCP without toxicity, and one patient refused treatment. The 2-year local control, disease-free survival, and overall survival rates were 37%, 12%, and 24%, respectively. The median survival time was 11 months. DISCUSSION: Treatment to 70.2 Gy and 75.6 Gy using 3D-CRT was delivered with acceptable morbidity when NTCP constraints were observed. Local control was encouraging in these patients with locally advanced disease. Patients are currently being accrued to the 81-Gy level of the study.

Adult↗