Search PubMed⌕ Search

Biomedical subjects

C Briguori

Publications and source records attributed to C Briguori.

At least 37 records · Page 2Linked to original sources

Emergency polytetrafluoroethylene-covered stent implantation to treat coronary ruptures.

BACKGROUND: Coronary perforation is a life-threatening complication of percutaneous interventions. In the past few years, the implantation of covered stents has emerged as a strategy for treatment when the traditional conservative approach (ie, prolonged balloon inflation and reversal of anticoagulation) fails. METHODS AND RESULTS: Since May 1997 (when polytetrafluoroethylene [PTFE]-covered stents were available at our institutions), 11 of the 12 consecutive patients who had coronary ruptures that were unsuccessfully sealed with prolonged balloon inflation and reversal of anticoagulation were treated with 12 PTFE-covered stents (PTFE group). The efficacy of the PTFE-covered stent was compared with that of noncovered stents, which were used to treat 17 perforations (non-PTFE group). One patient sustained a very distal perforation that was not suitable for covered stent sealing and underwent emergency surgery. All vessel ruptures treated with PTFE-covered stent implantation were successfully sealed. The time necessary to deploy the stent was 10+/-3 minutes (range, 4 to 15 minutes). All patients but one were discharged from the hospital and had an optimal early clinical outcome. One patient underwent emergency bypass surgery and died in the intensive care unit. The occurrence of cardiac tamponade and the necessity for emergency surgery was significantly lower in the PTFE group than in the non-PTFE group. At 14+/-4 months, the 10 discharged patients had not experienced any major adverse cardiac events. CONCLUSIONS: This preliminary study supports the utility of the PTFE-covered stent for the nonsurgical treatment of vessel ruptures.

Aged↗

Polytetrafluoroethylene-covered stent for the treatment of narrowings in aorticocoronary saphenous vein grafts.

We compared the outcome of patients with saphenous graft disease treated with polytetrafluoroethylene (PTFE)-covered stents or noncovered stents. Angiographic success was similar; non-Q-wave myocardial infarction was lower in the PTFE group (p = 0.06) and long-term major cardiac events and restenosis rate were similar in the 2 groups. Implantation of PTFE-covered stent in vein graft disease seems to reduce the occurrence of distal embolization.

Aged↗

Coronary stenting versus balloon angioplasty in small coronary artery with complex lesions.

The impact of stenting on small vessels (< 3.0 mm) with complex lesions (B2-C) is still controversial. Restenosis rate in this population is high (> 40%). We compared early and late outcome of patients with complex coronary lesions in small vessel treated with traditional coronary angioplasty (angioplasty group) and with elective stent implantation (stent group). Angioplasty group (n = 97) and stent group (n = 112) were comparable for all clinical and angiographic characteristics. All patients in the two groups had clinical and angiographic follow-up. Major adverse cardiac events (MACE) and restenosis rate were evaluated. No patients in the two groups experienced in-hospital death or bypass surgery. Myocardial infarction occurred in four patients in the angioplasty group and in seven patients in the stent group (P = 0.36). No patients in either the angioplasty or the stent group had acute stent thrombosis, whereas subacute stent thrombosis occurred in only one patients of the stent group (0.9%). Long-term MACEs (20 +/- 4 month) were not different in the two groups (angioplasty group 39% vs. stent group 44%, P = 0.35). Target lesion revascularization rate was 33% in the angioplasty group and 34% in the stent group (P = 0.50). Restenosis rate was not statistically different in the two groups (stent group 41% vs. angioplasty group 38%, P = 0.41). In conclusion, compared to balloon angioplasty, elective stent implantation in small vessels with complex lesions does not improve early and late outcome. Cathet. Cardiovasc. Intervent. 50:390-397, 2000.

Angioplasty, Balloon, Coronary↗

Bifurcation lesions: two stents versus one stent--immediate and follow-up results.

OBJECTIVES: The purpose of this study was to evaluate two different techniques of stent placement in bifurcation lesions. BACKGROUND: Although stent placement with dedicated techniques has been suggested to be a useful therapeutic modality for bifurcation lesions, limited information is available if stent placement on the side branch and on the parent branch provides any advantage over a simpler strategy of stenting the parent vessel and balloon angioplasty of the side branch. METHODS: Between March 1993 and April 1999, we treated a total of 92 patients with bifurcation lesions with two strategies: stenting both vessels (group B, n = 53) or stenting the parent vessel and balloon angioplasty of the side branch (group P, n = 39). Paired angiograms were analyzed by quantitative angiography, and clinical follow-up was obtained. RESULTS: Stent placement on both branches resulted in a lower residual stenosis (7.4 +/- 10.9% vs. 23.4% +/- 18.7%, p < 0.001) in the side branch. Acute procedural success was similar in the two groups (group B: 87% vs. Group P: 92%). In-hospital major adverse cardiac events (MACE) occurred only in group B (13% vs. 0%, p < 0.05). At the six-month follow-up, the angiographic restenosis rate (group B: 62% vs. Group P: 48%) and the target lesion revascularization rate (38% vs. 36%, respectively) were similar in the two groups. There was no difference in the incidence of six-month total MACE (51% vs. 38%). CONCLUSIONS: For the treatment of true bifurcation lesions, a complex strategy of stenting both vessels provided no advantage in terms of procedural success and late outcome versus a simpler strategy of stenting only the parent vessel.

Aged↗

Progressive decrease of outflow gradient and septum thickness after percutaneous alcoholization of the interventricular septum in hypertrophic obstructive cardiomyopathy.

BACKGROUND: The aim of this study was to evaluate the immediate- and mid-term results of percutaneous transluminal septal myocardial ablation (PTSMA) of the interventricular septum performed in 15 consecutive patients with hypertrophic obstructive cardiomyopathy between 1996 and 1999. METHODS: Prior to intervention, all patients (7 males, 8 females, mean age 62 +/- 11 years) complained of severe dyspnea (NYHA functional class III-IV) despite medical treatment with beta-blockers and/or verapamil. Family history of hypertrophic cardiomyopathy was present in 2 cases. Dehydrated alcohol (4.8 +/- 1.5 ml/pt) was selectively infused into the first septal perforator artery through over-the-wire balloon catheters. In 5 patients a second or a third septal branch was treated because the intraventricular gradient persisted above 50 mmHg after the initial alcohol infusion. RESULTS: Alcohol infusion induced an average peak creatine phosphokinase level of 1,524 +/- 427 IU/l. No iterating ventricular arrhythmias occurred during the procedure or in the 2-3 days of continuous ECG monitoring after the procedure. Two patients (13%) developed a complete atrioventricular block after the procedure, requiring permanent double-chamber pacing. Electrocardiographic changes included a > 2 mm ST segment elevation and transient right bundle branch block or left anterior/left posterior hemiblock in all patients. Peak basal intraventricular gradient decreased from 80 +/- 27 to 24 +/- 27 mmHg (p < 0.01) during cardiac catheterization and from 81 +/- 27 to 35 +/- 25 mmHg (p < 0.01) at the echocardiographic control performed during the hospital stay. At follow-up (mean 5.1 +/- 3.6 months), all patients were in NYHA functional class I or II. Repeat echocardiography showed a further significant decrease in intraventricular gradient to 25 +/- 26 mmHg (p < 0.01) and a progressive decrease in intraventricular septum thickness (25 +/- 5 mm before treatment, 21 +/- 6 mm before hospital discharge, 17 +/- 3 mm at follow-up, p < 0.01). CONCLUSIONS: PTSMA of the intraventricular septum effectively relieves symptoms in selected patients with hypertrophic obstructive cardiomyopathy. The immediate decrease in intraventricular gradient is followed by a further decline at follow-up with a progressive reduction in the intraventricular septum thickness.

Aged↗

Multivessel coronary stenting: predictors of early and late outcome.

BACKGROUND: At present, only few data are available on the early and late outcome following multivessel coronary stenting. Of note, in these studies, the left anterior descending (LAD) artery was treated in less than 40% of cases. These patients may not fully represent the population commonly referred for surgical revascularization. METHODS: In-hospital and long-term (18 +/- 4 months) events were evaluated in 272 consecutive patients who had multivessel stent implantation including the LAD artery in each case. All clinical, angiographic, and procedural variables were analyzed to identify the predictors of acute and long-term major adverse coronary events. RESULTS: Eighteen patients (6.6%) had in-hospital major adverse coronary events (death 0.7%, coronary artery bypass grafting 0.4%, and myocardial infarction 6.3%). Acute and subacute stent thrombosis rates were 1.5 and 1.1%, respectively. At 18 +/- 4 months, event-free survival was 71%. Target lesion revascularization was performed in 54 (20%) patients (42 coronary angioplasty and 12 coronary artery bypass grafting). The jeopardy score was the predictor of in-hospital major adverse coronary events (p = 0.016, odds ratio 1.34, 95% confidence interval 1.05-1.69), and diabetes mellitus was the predictor of long-term major adverse coronary events (p = 0.027, odds ratio 2.80, 95 % confidence interval 1.12-6.96). CONCLUSIONS: Multivessel coronary stent implantation with treatment of the LAD artery in all instances is a safe procedure with low acute and long-term major adverse coronary events. The risk-benefit ratio must be assessed carefully for each patient, particularly taking into account the jeopardy score and the presence of diabetes mellitus.

Aged↗

Contemporary percutaneous treatment of saphenous vein graft stenosis: immediate and late outcomes.

PURPOSE: The aim of this study was to evaluate the immediate and long-term outcomes following percutaneous treatment of an unselected series of saphenous vein graft (SVG) lesions. METHODS AND RESULTS: Consecutive interventions on 129 saphenous vein graft lesions in 101 patients were reviewed. Stents were implanted in 114 lesions (88%), which included the use of polytetrafluoroethylene-covered stents in 22 lesions (17%) and abciximab in 20 patients (20%). Angiographic success was achieved in 125 lesions (97%). In-hospital major adverse cardiac events (MACE) occurred in 11 patients (11%), with myocardial infarction being the most frequent event. Treatment of degenerated SVG lesions and SVG lesions with larger reference diameters correlated with the incidence of in-hospital MACE [odds ratio (OR) = 7.69 and 2.65, respectively; 95% confidence interval (CI) = 1.80Eth 32.8 and 0.99Eth 7.10, respectively)]. Clinical follow-up was achieved in all patients at 25 +/- 21 months. Successful revascularization to all three distributions of the major coronary arteries negatively correlated [relative risk (RR) = 0.43; 95% CI = 0.20Eth 0.92)], while treatment of a degenerated SVG positively correlated (RR = 1.92; 95% CI = 1.05Eth 3.51) with the occurrence of follow-up MACE. A final effective blood supply to the anterior wall and a higher left ventricular ejection fraction was found to negatively correlate with the occurrence of follow-up death (RR = 0. 20 and 0.61, respectively; 95% CI = 0.06Eth 0.60 and 0.41Eth 0.90, respectively). CONCLUSION: Treatment of SVG lesions continues to be associated with a high incidence of myocardial infarction, particularly in cases of degenerated SVG lesions. An effective blood supply to the anterior wall and a higher left ventricular ejection fraction were protective for the occurrence of death during the follow-up period.

Aged↗

Exercise capacity in hypertrophic cardiomyopathy depends on left ventricular diastolic function.

Some studies have demonstrated that left ventricular (LV) diastolic function is the principal determinant of impaired exercise capacity in hypertrophic cardiomyopathy (HC). In this study we sought the capability of echocardiographic indexes of diastolic function in predicting exercise capacity in patients with HC. We studied 52 patients with HC while they were not on drugs;12 of them had LV tract obstruction at rest. Diastolic function was assessed by M-mode and Doppler echocardiography by measuring: (1) left atrial fractional shortening, and the slope of posterior aortic wall displacement during early atrial emptying on M-mode left atrial tracing; and (2) Doppler-derived transmitral and pulmonary venous flow velocity indexes. Exercise capacity was assessed by maximum oxygen consumption by cardiopulmonary test during cycloergometer upright exercise. Maximum oxygen consumption correlated with the left atrial fractional shortening (r = 0.63, p <0.001), the slope of posterior aortic wall displacement during early atrial emptying (r = 0.55, p <0.001), age (r = -0.50; p <0.001), pulmonary venous diastolic anterograde velocity (r = 0.41, p <0.01), and the systolic filling fraction (r = -0.43; p <0.01). By stepwise multiple linear regression analysis, left atrial fractional shortening and the pulmonary venous systolic filling fraction were the only determinants of the maximum oxygen consumption (multiple r = 0.70; p <0.001). Exercise capacity did not correlate with Doppler-derived transmitral indexes. Thus, in patients with HC, exercise capacity was determined by passive LV diastolic function, as assessed by the left atrial M-mode and Doppler-derived pulmonary venous flow velocities.

Adolescent↗

Prevention of distal embolization during saphenous vein graft lesion angioplasty. Experience with a new temporary occlusion and aspiration system.

BACKGROUND: Repeat coronary artery bypass graft surgery (CABG) is associated with a high morbidity and mortality, rendering percutaneous treatment of saphenous vein graft (SVG) lesions an attractive alternative. However, percutaneous interventions of degenerated SVGs carries high risk of distal embolization. METHODS AND RESULTS: This study reports our initial experience with the PercuSurge GuardWire, a new device developed to prevent embolization during treatment of degenerated SVG. This device consists of a 190-cm-long, hollow 0.014-in guidewire with a central lumen connected to a distal occlusion balloon. A dedicated inflation device (the MicroSeal Adapter) was used to inflate the distal balloon and maintain complete lumen occlusion during balloon dilatation and stent implantation. A monorail aspiration catheter, connected to a vacuum syringe, was used to evacuate atherosclerotic and thrombotic debris. Angioplasty with stent implantation was performed in 15 degenerated SVGs (18 lesions). Procedural success was achieved in all patients with normal postprocedure flow (Thrombolysis in Myocardial Infarction grade 3). No distal embolization was observed. There were no major in-hospital adverse clinical events, including Q-wave or non-Q-wave myocardial infarction, emergency CABG, or death. All patients were asymptomatic at discharge. CONCLUSIONS: This preliminary series supports the feasible use of the PercuSurge GuardWire for retrieval of plaque debris and prevention of embolization in degenerated SVGs. The good tolerance of temporary occlusions without angiographic or clinical evidence of distal embolization represents encouraging early findings.

Aged↗

Influence of left ventricular cavity size on clinical presentation in hypertrophic cardiomyopathy.

The aim of this study was to assess whether left ventricular (LV) cavity size relates to functional impairment and syncope in patients with hypertrophic cardiomyopathy (HC). LV diastolic dysfunction influences functional limitation in HC. A reduced LV end-diastolic dimension may underlie impaired diastolic properties and be implicated in hemodynamic syncope. Eighty-two consecutive patients with HC (off drugs, in sinus rhythm) underwent echocardiography to measure LV end-diastolic dimension in the short-axis view (indexed to the body surface area) and radionuclide angiography (n = 50) to calculate peak filling rate (normalized to stroke counts/s). Patients in New York Heart Association functional classes II to IV had smaller LV end-diastolic dimension (23.2 +/- 2.6 vs 25.5 +/- 2.5 mm/M2, p = 0.0001) and lower peak filling rate (4.3 +/- 1.4 vs 5.1 +/- 1.3 stroke counts/s, p = 0.036) than those in New York Heart Association class I. LV end-diastolic diameter was correlated to peak filling rate (r = 0.37; p = 0.008). The most potent predictors of functional limitation were LV end-diastolic dimension (relative risk [RR] 0.63, confidence interval [CI] 0.45 to 0.88; p = 0.008), age (RR 1.09, CI 1.03 to 1.17; p = 0.003), and LV thickness score (RR 1.08, CI 1.02 to 1.13; p = 0.003). LV cavity size was smaller in patients with functional limitation irrespective of obstruction and hypertrophy. Patients with differed from those without a history of syncope for a smaller LV end-diastolic dimension (23.2 +/- 2.5 vs 25.0 +/- 2.7 mm/M2, p = 0.008), which was the only independent predictor of syncope (RR 0.77, CI 0.63 to 0.95; p = 0.013). Thus, a small LV cavity size is associated with functional limitation and history of syncope in HC.

Adolescent↗

Administration of protamine after coronary stent deployment.

BACKGROUND: Prompt reversal of anticoagulation by protamine administration could be an important therapeutic option to treat serious procedural complications such as vessel rupture or major bleeding from the puncture site during coronary stent implantation. However, this therapeutic option is rarely used because of the possible risk of stent thrombosis. METHODS: We retrospectively analyzed the incidence of acute and subacute stent thrombosis and vascular complications in 90 patients who received protamine (protamine group) and 1763 patients who did not receive protamine (control group) after successful coronary stent implantation. The 2 groups were matched for clinical, angiographic, and procedure characteristics. RESULTS: No patients in the protamine group had adverse effects such as hypotension or vascular collapse during protamine administration. Acute stent thrombosis did not occur in any protamine group patient but did occur in 12 patients in the control group (0.7%) (P =.47). Subacute stent thrombosis occurred in 2 patients in the protamine group (2.1%) and in 15 in the control group (0.8%) (P =.20). By logistic regression analysis, protamine was not a determinant of stent thrombosis. CONCLUSIONS: Reversal of anticoagulation by protamine after stent implantation does not predispose to stent thrombosis. This result has important clinical consequences because it allows the use of protamine in the treatment of coronary perforation and serious bleeding complications that may occur during coronary stent deployment.

Aged↗

Primary stenting and glycoprotein IIb/IIIa inhibitors in acute myocardial infarction.

Early patency of the infarct-related vessel improves in-hospital and long-term survival. Mechanical reopening is as effective as or superior to pharmacological therapy in the treatment of acute myocardial infarction. However, in patients treated with primary percutaneous transluminal coronary angioplasty, recurrent ischemia occurs in 10% to 15% before hospital discharge, and angiographic restenosis occurs in 30% to 50% of infarct-related vessel within 6 months. Primary stenting in acute myocardial infarction has been found to be safe and feasible and reduces early and late events. In particular, restenosis rate has been found to be lowered by stent implantation. Use of glycoprotein IIb/IIIa receptor inhibitors alone has resulted in infarct-related vessel patency rates approximately the same as with the use of thrombolytic therapy. Furthermore, glycoprotein IIb/IIIa receptor blockers reduce the occurrence of acute complications during percutaneous transluminal coronary angioplasty. Preliminary results of some ongoing trials showed that the combined therapeutic approach (ie, primary stenting plus glycoprotein IIb/IIIa inhibitors) in patients with acute myocardial infarction reduces both early and late complications of percutaneous transluminal coronary angioplasty. This finding supports the concept that optimal mechanical resolution of the plaque and the inhibition of platelet aggregation are the key of the treatment of the infarct-related vessel.

Angioplasty, Balloon, Coronary↗

Determinants of aortic artifacts during transesophageal echocardiography of the ascending aorta.

BACKGROUND: The origin of artifacts of the ascending aorta during transesophageal echocardiography has not been widely studied. This study was undertaken to investigate in vivo whether anatomic features could determine the appearance of artifacts. METHODS AND RESULTS: Transesophageal echocardiograms of 46 patients studied for suspected dissection with proven diagnosis (30 patients with and 16 without ascending aortic dissection) were reviewed. The incidence of artifacts was 46%, and it was similar in patients with and those without dissection (chi-square 0.516; P = not significant). Artifacts were located in the aortic lumen twice as far from the transducer as the atrial-aortic interface. The aortic diameter was larger in patients with than in those without artifacts (6.4 +/- 1.1 vs 4.2 +/- 0.9 cm, P <.001). An aortic diameter >5 cm and an atrial-aortic ratio </=0.6 predicted the artifact appearance with good sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy; these parameters reached a value of 100% by analysis only of patients without dissection. CONCLUSIONS: An ascending aortic diameter >5.0 cm that exceeds the left atrial diameter with an atrial-aortic ratio </=0.6 creates in vivo the conditions for the reverberation of the atrial-aortic interface within the aorta. Therefore, in patients with such anatomic features, artifacts must be suspected in the presence of linear structures within the aorta.

Aortic Dissection↗

Direct coronary stenting without predilation.

OBJECTIVES: Coronary stenting is the primary therapeutic option for percutaneous treatment of many coronary lesions, after the risk of subacute stent thrombosis and bleeding complications has been reduced by improved antithrombotic regimens and high pressure stent expansion. BACKGROUND: Direct stent implantation (without predilation) has been considered a promising new technique that may reduce the procedure time, radiation exposure time and cost. METHODS: After having reviewed all cases of stent implantation from February to June 1998 (n = 585), 185 (32%) of these patients were retrospectively considered candidates for direct stent implantation without predilation, according to prespecified criteria (i.e., absence of severe coronary calcifications and/or tortuosity of the lesion or the segment proximal to the lesion). By operator preference, direct coronary stent implantation was actually attempted in 123 (21%) of the 585 patients (100 men, 60 +/- 10 years old) on 123 lesions. The impact of direct stenting in terms of cost, procedure time, radiation exposure time and amount of contrast dye used was assessed by comparing the two groups of patients who underwent single-vessel stenting without (n = 69) and with (n = 46) predilation. RESULTS: Direct stenting was successful in 118 patients (96%). No acute or subacute complications occurred in these patients. Procedure time, radiation exposure time and cost were significantly lower in the group of patients who had single-vessel direct versus conventional stenting (45 +/- 31 vs. 64 +/- 46 min, 12 +/- 9 vs. 16 +/- 10 min and 1,305 +/- 363 vs. 2,210 +/- 803 Euro, respectively; p < 0.05 for all). CONCLUSIONS: Direct stenting without predilation in selected lesions seems to be a safe and successful procedure that provides a way to contain cost and to shorten radiation exposure time.

Angioplasty, Balloon, Coronary↗

Noninvasive evaluation of left ventricular diastolic function in hypertrophic cardiomyopathy.

Diastolic dysfunction is common in hypertrophic cardiomyopathy (HC). Previous studies suggest that Doppler transmitral flow velocity profiles, and the left atrial (LA) M-mode echogram can be used noninvasively to evaluate left ventricular (LV) diastolic function. However, this has not been proved in HC. In this study we determined the relation of Doppler transmitral flow velocity profiles and the LA M-mode echograms to invasive indexes of LV diastolic function in patients with HC. We studied 25 patients with HC, while off drugs, and calculated LA global and active fractional shortening and the slope of both early and late displacement of the posterior aortic wall during LA emptying by M-mode echocardiography. We calculated peak velocity of early (E) and atrial (A) filling, E to A ratio, and E-wave deceleration time by pulsed Doppler echocardiography, and simultaneous radionuclide angiography, LV pressures, time constant of isovolumic relaxation tau, and the constant of chamber stiffness k by cardiac catheterization. The time constant of isovolumic relaxation tau correlated with the slope of early posterior aortic wall displacement (r = 0.59; p <0.01). LV end-diastolic pressure correlated with global LA fractional shortening (r = -0.75; p <0.001); the constant of chamber stiffness k correlated with active LA fractional shortening (r = -0.53; p <0.02). In a subset of 13 patients, in whom echocardiography and cardiac catheterization were performed simultaneously, similar results were found. LA M-mode recordings provide a more reliable noninvasive assessment of diastolic function in HC than mitral Doppler indexes.

Adolescent↗

Pattern of left ventricular filling in hypertrophic cardiomyopathy. Assessment by Doppler echocardiography and radionuclide angiography.

AIMS: The left ventricle in hypertrophic cardiomyopathy is anatomically and functionally non-uniform. This study was undertaken to verify whether a heterogeneity in the pattern of diastolic filling can be detected along the left ventricular inflow tract in hypertrophic cardiomyopathy. METHODS AND RESULTS: Early (E) and late (A) diastolic velocities were recorded by Doppler echocardiography at mitral and at mid-ventricular level in 16 normal volunteers and 30 patients with hypertrophic cardiomyopathy. Patients with hypertrophic cardiomyopathy also underwent radionuclide angiography to assess left ventricular function. E wave decreased significantly in normal volunteers (80 +/- 15 to 60 +/- 14 cm x s(-1); P<0.001), but it increased in hypertrophic cardiomyopathy (76 +/- 22 to 87 +/- 28 cm x s(-1) P=0.04), whereas the A wave decreased similarly in both. By multivariate analysis, systolic asynchrony and the ejection fraction of left ventricular lateral wall were directly related to the pattern of early filling progression (r=0.656, F=9.467; P<0.002). Moreover, systolic asynchrony showed a univariate direct correlation with changes in E velocity (r=0.42; P=0.02). CONCLUSION: Many patients with hypertrophic cardiomyopathy have an acceleration of filling within the left ventricular inflow tract; this phenomenon is directly related to systolic asynchrony and ejection fraction of the left ventricular lateral wall, suggesting increased suction.

Adolescent↗