Search PubMed⌕ Search

Biomedical subjects

C Blanche

Publications and source records attributed to C Blanche.

At least 73 records · Page 4Linked to original sources

Morbidity and mortality after coronary artery bypass in octogenarians.

One hundred fifty seven consecutive octogenarians (mean age +/- standard deviation, 82.4 +/- 1.9 years) underwent coronary artery bypass grafting with hypothermia (mean temperature, 21.8 degrees +/- 1.8 degrees C), hyperkalemic cardioplegia, and cardiopulmonary bypass in a 9-year period. Sixty-six percent were male. Preoperatively, 115 patients (73%) were in New York Heart Association functional class IV, with the remainder being in either class III (23%) or class II (4%). Twenty percent of the patients had major complications including postoperative hemorrhage (15), sepsis (9), cerebrovascular accident (6), third-degree heart block (5), renal failure requiring dialysis (1), and pulmonary embolism (1). The 30-day or in-hospital mortality rate was 7.0%. Mean total hospital stay was 26.1 +/- 17.9 days. One-year and 5-year actuarial survival rates were 85% and 62%, respectively. Higher mortality was seen to be associated with New York Heart Association class IV, left ventricular ejection fraction less than 0.40, and lesser values for cardiac output and cardiac index. At the 6-month postoperative follow-up, 73% of the survivors reported that their general health had improved as compared with before operation. This experience demonstrates that for select octogenarians with unmanageable angina pectoris, coronary artery bypass grafting is an effective therapeutic option.

Aged↗

Internal mammary artery to lung parenchyma fistula after aortocoronary bypass grafting.

Two unusual cases of internal mammary artery fistulization to lung parenchyma after coronary revascularization are reported. They were incidentally discovered during coronary angiography, and one of them was successfully closed with a percutaneous transvenous coil-spring occluder. The cause is thought to be the direct contact between the dissected mammary artery pedicle and the lung parenchyma.

Coronary Artery Bypass↗

Fatal poisoning by Rumex crispus (curled dock): pathological findings and application of scanning electron microscopy.

A case of fatal poisoning due to ingestion of the plant Rumex crispus (curled dock) is described. The patient, a 53-year-old male, presented with gastrointestinal symptoms, severe hypocalcemia, metabolic acidosis and acute hepatic insufficiency. Despite therapeutic measures, the patient died 72 h after ingestion of the plant material. Noteworthy among the pathological findings were centrolobular hepatic necrosis and birefringent crystals in the liver and kidneys that were identified by histochemical techniques and scanning electron microscopy. These observations are compared with other reports in the medical literature, with an emphasis on the risk involved in the use of these plants for culinary or medicinal purposes.

Edema↗

Ten-year experience with the St. Jude Medical valve for primary valve replacement.

The St. Jude Medical valve is a bileaflet prosthesis with excellent hemodynamic characteristics, but the long-term surgical experience with this valve, its durability, and its biocompatibility are unknown. During a 10-year period from March 1978 to 1988, 690 prostheses (290 aortic, 252 mitral, and 74 double aortic-mitral) were inserted as the initial valve replacement substitute in 616 patients (mean age 63 years). Coronary atherosclerosis was present in 58%. Follow-up totaled 2031 patient-years (mean 3.3 years) and was 95% complete (32 lost). Early (30-day) mortality rates were 5.2%, 11.9%, and 8.1% after aortic, mitral, and double valve replacement; 5- and 9-year actuarial survival rates were 71% +/- 3% and 51% +/- 8%, 59% +/- 4% and 41% +/- 6%, and 69% +/- 6% and 47% +/- 15%, respectively. Deaths were associated with extensive coronary atherosclerosis (p less than 0.001), older age (p less than 0.001), advanced preoperative New York Heart Association functional class (p less than 0.05), and malignant ventricular arrhythmias (p less than 0.05). No structural failures have been observed. Embolism (40 events) occurred at a rate of 2.0%/pt-yr (2.3% aortic, 1.6% mitral, 2.0% double). There were six cases of valve thrombosis (0.3%/pt-yr; one fatal). Hemorrhage was the most frequent complication (2.6%/pt-yr); 13 (25%) of 52 events were fatal, accounting for 62% of all valve-related deaths. After the target prothrombin time ratio was lowered, the rate of hemorrhage decreased by 44% (2.7% to 1.5%/pt-yr), while the combined rate of embolism and valve thrombosis increased slightly (2.2% to 2.5%/pt-yr, a 14% change). In summary, the St. Jude Medical valve remains a durable valve substitute. Survival was strongly related to the presence of associated coronary atherosclerosis. The most common complication has been hemorrhage; a less intensive warfarin regimen may reduce hemorrhagic risk while maintaining thromboembolic protection.

Adolescent↗

Thermal coronary angiography: a method for assessing graft patency and coronary anatomy in coronary bypass surgery.

Thermal coronary angiography was evaluated in 50 patients undergoing 137 saphenous vein and 48 internal mammary artery bypass grafts. A total of 177 thermal coronary angiograms were performed after completion of the distal anastomoses by injection of cold cardioplegia into the vein or by reperfusion with warmer blood in the internal mammary artery grafts. These angiograms provided details of graft and anastomosis patency, flow directions, and presence of native coronary stenoses. Temperature differences between the injectant and the epimyocardium of greater than 4 degrees C resulted in high-contrast images. Thermal coronary angiograms were obtained in 173 of the 177 studied bypass grafts; 172 grafts were patent, and 1 internal mammary artery graft was occluded. Unsuspected stenoses were detected at the site of four distal anastomoses. Subsequently, two anastomoses were successfully revised and three additional grafts performed. Ninety-six native coronary stenoses were located in the recipient coronary arteries. In ten instances, the thermal coronary angiograms were obscured by excess fat or myocardium, thereby impeding correct image analysis. We conclude that thermal coronary angiography can be clinically relevant and helps improve decision making during coronary artery bypass operations.

Adult↗

Intraoperative evaluation of mitral regurgitation by Doppler color flow mapping.

Excessive residual mitral regurgitation after mitral valve reconstruction or coronary artery bypass graft surgery may necessitate reoperation. We evaluated a new intraoperative technique for assessment of mitral regurgitation, real-time two-dimensional Doppler color flow mapping, in 96 patients undergoing cardiac surgery. In comparison with technically adequate preoperative left ventriculography (n = 68) obtained at a similar level of afterload (systolic arterial pressure), Doppler color flow mapping demonstrated a sensitivity of 94% (50/53) and specificity of 93% (14/15) for detection of the presence and absence of mitral regurgitation, respectively. Semiquantitative comparison of color Doppler with angiography demonstrated excellent agreement (kappa = .80, p less than .001), differing by more than one grade in two patients (3%). The pulmonary capillary wedge "V" wave pressure (absolute magnitude, and height above mean) correlated poorly with the simultaneously obtained mitral regurgitation grade by color Doppler, both before (r = .37 and .45) and after (r = .04 and -.15, p = NS) cardiopulmonary bypass. No value of the V wave clearly distinguished 3 + or 4 + regurgitation from lesser degrees of regurgitation. In 15 patients who underwent mitral valve repair, fluid filling of the ventricle was falsely positive (leak, with no regurgitation) in 40% (2/5), and falsely negative (no leak, with 2 + to 3 + regurgitation) in 30% (3/10). Regurgitation grade by color Doppler demonstrated a highly significant (p less than .01) dependence on systolic pressure, suggesting that intraoperative changes in afterload conditions importantly influence mitral regurgitation severity. Thus, Doppler color flow mapping provides accurate intraoperative evaluation of mitral regurgitation and may aid surgical decision making.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Vessel Prosthesis↗

Coronary angioscopy in patients with unstable angina pectoris.

To visualize intracoronary lesions in patients with different clinical expressions of coronary disease, we performed coronary angioscopy during coronary-artery bypass surgery in 10 patients with unstable angina and 10 patients with stable coronary disease. We examined a total of 32 vessels, using flexible fiberoptic angioscopes. Twenty-two vessels had no acute intimal lesion; three had complex plaques, six had thrombi, and one had both. Coronary angiography correctly identified the absence of complex plaque and thrombus in 22 vessels, but it detected only one of four complex plaques and one of seven thrombi. On angioscopy, none of the 17 arteries in the patients with stable coronary disease had either a complex plaque or thrombus. In the "offending" arteries of the patients with unstable angina, all three patients with accelerated angina had complex plaques and all seven with angina at rest had thrombi. We conclude that angioscopy frequently reveals complex plaques or thrombi not detected by coronary angiography. Our observations suggest that anginal syndromes that are refractory to medical treatment can be caused by unstable pathologic processes in the intima. Ulceration of plaques may increase the frequency and severity of effort angina, and the subsequent development of partially occlusive thrombi may cause unstable rest angina.

Adult↗

Intraoperative coronary angioscopy. Technique and results in the initial 58 patients.

Coronary angioscopy provides images of intravascular detail with greater than 0.2 mm spatial resolution and excellent contrast resolution. Using endoscopes of 1.25 to 1.8 mm outer diameter, we performed intraoperative angioscopy of the coronary arteries or saphenous vein grafts, or both, in 58 patients. Eighty-one native coronary arteries and 43 vein grafts were examined. A clear viewing field was created by infusion of crystalloid cardioplegic solution through the aortic root during cardiopulmonary bypass. Technical details crucial for obtaining high-quality images were as follows: sufficient coronary perfusion by cardioplegic solution to displace all blood; adequate intraluminal illumination; and high-quality fiberoptic and lens systems. Incomplete studies in approximately 14% of patients were related to failure to achieve these technical details and lack of scope steerability. In 30% of patients, previously unrecognized anatomic details were revealed by angioscopy. These included intimal flaps at the site of vein-to-artery anastomoses, atheromatous plaques with adherent thrombi, and hemorrhagic ulcerated plaques, not recognized on angiography. Although a coronary intimal flap developed proximal to the anastomosis during retrograde examination in two patients, no serious complications occurred as a result of the procedure. We conclude that intraoperative angioscopy is safe, provides novel information that may be clinically relevant, and has future potential for development of the techniques for coronary endarterectomy and intraoperative balloon and laser angioplasty.

Angina, Unstable↗

Free-floating ball thrombus in the left atrium after mitral valve replacement: successful surgical management.

A free-floating ball thrombus in the left atrium is a rare clinical problem with potentially catastrophic consequences. Thus, early diagnosis and prompt surgical intervention are mandatory. Free ball-valve thrombus within the left atrium developed in a patient who had undergone mitral valve replacement with a Starr-Edwards prosthesis seven years previously. The diagnosis was accurately made by two-dimensional echocardiography and was followed by successful removal of a thrombus. A review of the literature is presented.

Echocardiography↗

Influence of ethanol on the human serum level of beta-hexosaminidase.

Serum activities of the lysosomal enzymes beta-hexosaminidase, alpha-fucosidase and alpha-mannosidase in teetotalers, healthy persons with 'ordinary' alcohol consumption, chronic alcoholics and patients with alcoholic liver cirrhosis were compared. There was no difference between controls and teetotalers, whereas serum from chronic alcoholics and patients with alcoholic liver cirrhosis showed a significant increase of lysosomal enzymes compared to controls and teetotalers. The effect of daily alcohol ingestion on the serum activity of lysosomal enzymes was studied in 9 healthy volunteers. A minor but significant increase was found for beta-hexosaminidase. It is concluded that the increase of lysosomal enzyme activity in serum from alcoholics is due to the liver dysfunction.

Adolescent↗

Coronary artery dissection secondary to coronary arteriography: case report and review.

A case of catheter-induced proximal dissection of an angiographically normal left coronary artery is reported. Dissection was not associated with pressure damping and myocardial ischemia was delayed until 1 hour after dissection occurred. Prompt recognition of this entity is essential as emergency revascularization is the treatment of choice when significant amounts of myocardium are threatened.

Cardiac Catheterization↗

Curvilinear paramedian sternotomy.

A modification of the classic straight midline sternotomy incision is described. The technique involves performing the sternotomy in a curvilinear manner along both sides of the midline to create two sternal halves that interdigitate with one another. With such a configuration, malalignment is virtually impossible.

Humans↗

Use of stapling instruments in surgery for aneurysms of the aorta.

Since their inception, surgical stapling devices have been used almost exclusively in pulmonary and gastrointestinal procedures. We present our experience with surgical staplers in operations for aneurysms of the aorta. Three illustrative case reports are presented that demonstrate the applicability of surgical stapling devices in excluding aortic aneurysms. Seven patients have undergone operation using this technique, all with excellent technical results. We believe that surgical stapling devices represent a safe, easy, and rapid means of excluding aneurysms of the aorta.

Aorta, Thoracic↗