Search PubMed⌕ Search

Biomedical subjects

C Baquey

Publications and source records attributed to C Baquey.

At least 55 records · Page 3Linked to original sources

Polyurethanes grafted by pendent groups with different sizes and functionality.

Polyurethanes grafted by pendent alkyl chains along the backbone have been prepared and characterized by their mechanical properties and by in vitro adsorption of albumin and fibrinogen. The grafting of butyl, octyl, decyl, hexadecyl and tetratriacontyl chains on to the urethane nitrogen weakens the stress-strain properties, whereas these properties remain high when these alkyl groups are grafted on the 1,3-propanediol used as chain extender. The hexadecyl chain gives the highest values of albumin adsorption from in vitro tests. Polyurethanes prepared from a commercial diol bearing a polyoxyethylene-polyoxypropylene propylsulphonate side chain adsorb albumin and fibrinogen, the respective amounts depending on the substitution yield of the sulphonate group.

Adsorption↗

In vitro study of the hemocompatibility of superparamagnetic contrast agent for magnetic resonance imaging.

Five different nanoparticles, potentially useful in magnetic resonance imaging (MRI) after venous administration, were studied for their hemocompatibility. The in vitro methodology evaluated these materials by several parameters: cytotoxicity towards cells cultured in vitro, aggregation ability of platelets, hemolysis inducibility, intrinsic and extrinsic coagulation pathway activation, and complement activation. With the proposed clinical dose, regardless of the cell type used (murine cell line or human endothelial cells) no toxicity was observed. The presence of the particles in blood did not produce any considerable damage: either hemolysis or platelet aggregation or blood coagulation were recorded. However, a slight decrease in aggregation ability of platelets was noticed as well as an increase in partial thromboplastin time. Because of the quick removal of the particles from the bloodstream, these phenomena must be short-lived, thus avoiding significant adverse clinical effects.

Animals↗

Mechanical properties of cellulose in orthopaedic devices and related environments.

The authors have undertaken a series of mechanical tests in order to assess the performance of regenerated cellulose under either static or dynamic conditions, and to evaluate its long-term behaviour under mechanical stress. In this respect, bending stiffness, resistance to compression, creep under compressive stress, in vitro and in vivo ageing and fatigue resistance were studied. It appears that this material demonstrates mechanical properties which depend upon its density, which is itself related to its water content. Moreover, this material is very stable under dynamic stress. This could be an interesting property for use in orthopaedic devices.

Cellulose↗

An ex vivo original test using radiotracers for evaluating haemocompatibility of tubular biomaterials.

The haemocompatibility of a vascular prosthesis can be estimated as the result of its interaction with blood components. The authors describe an ex vivo canine shunt for evaluating isotopic haemocompatibility in blood-wall interactions. Methods employing radioisotopic tracers can be used to dynamically monitor the adsorption of labelled blood cells and proteins on different biomaterial surfaces. This ex vivo test should enable materials to be assessed for quality according to two thrombogenic criteria: (i) number of adhered platelets mm-2 s-1; (ii) quantity of adsorbed fibrinogen expressed as microgram mm-2 s-1, which would provide the basis for a scale of haemocompatibility.

Animals↗

A canine ex vivo shunt for isotopic hemocompatibility evaluation of a NHLBI DTB primary reference material and of a IUPAC reference material.

Factors determining the thrombogenic response to particular artificial surfaces were investigated ex vivo in a canine shunt model. Methods using radioisotopic tracers made it possible to dynamically monitor the deposition of labelled blood cells and proteins on a NHLBI.DTB primary reference material polydimethylsiloxane (PRM.PDMS) and on a IUPAC reference material polyvinyl chloride (IUPAC.PVC). On the one hand, leukocyte affinity tau s(leu) (number of deposited leukocytes mm-2s-1) was not significantly different between IUPAC.PVC (tau s(leu) = 1.2-2.5) and PRM.PDMS (tau s(leu) = 1.5-3.4) and the fibrinogen adsorption rate varied from 33 to 48.10(-5) micrograms mm-2s-1 for both these materials. On the other hand, platelet affinity tau s(plat) (number of deposited platelets mm-2s-1) was significantly different (p < 0.05) for IUPAC.PVC and PRM.PDMS (tau s(plat)PVC = 683 +/- 200 > tau s(plat)PDMS = 327 +/- 80). Scanning electron micrographs of adherent platelets, red cells and leukocytes after blood contact ex vivo were performed after each experiment. This preliminary work contributes not only to quantify the adsorption of different radiotracers, but also to evaluate the superficial distribution of the labelled biological species on the inner surface of the tested biomaterials.

Animals↗

Endothelial cell compatibility testing of three different Pellethanes.

There is a need for viable small diameter vascular grafts, the luminal surface of which could be seeded by endothelial cells (ECs) to prevent thrombosis. In order to select candidates for EC seeding before implantation, the in vitro cytocompatibility of three different Pellethanes (polyetherurethanes) using human ECs was investigated. The methodology included two stages depending on either direct contact between cells and materials or contact between cells and material extracts, obtained under standardized conditions. By the latter method, we observed a cytotoxic effect on cell growth with 2363-55 D Pellethane extract at a 50% (v/v) concentration in the nutrient medium, likely provoked by leachables and correlated with the lowest levels of tPA, PAI1, and vWF antigens in the supernatants. By the former method, we studied EC attachment and growth. Morphology was studied by classical means and completed by scintigraphy and microautoradiography after 111Indium-labeling of the EC monolayer. Differentiation was determined by the release of vWF antigen and measurement of vWF activity (multimeric organization) after human thrombin stimulation. Despite an inhibition of proliferation for both 55 D and 75 D types (compared to the control), a functional monolayer of ECs was obtained on 75 D. Pellethane 75 D could be the best support for in vitro endothelization.

Blood Vessel Prosthesis↗

Study of in vitro and in vivo stability of liposomes loaded with calcitonin or indium in the gastrointestinal tract.

Factors affecting liposome transport to the blood compartment after oral administration to rats were evaluated. A high entrapment of calcitonin (CT) was obtained when the vesicles were prepared by sonication and were composed of egg phosphatidylcholine, cholesterol and stearylamine. In vitro tests showed that the liposomes were stable in light acidic or basic buffers, but that they were partly lysed in pH 2.5, 10 mM bile salts and pancreatin. Oral administration of liposomes entrapping calcitonin in fasting rats showed that the vesicles facilitate transport of the hormone to the general circulation and that they increase the lifetime of 125I-CT in blood. Oral administration of liposomes entrapping radioactive indium in fasting rats did not induce radioactivity in blood. This could be explained by disruption of most of the vesicles in the enterocytes.

Administration, Oral↗

TiN coating: surface characterization and haemocompatibility.

The left ventricular assist device under consideration is based on the principle of the Maillard-Wankel rotary pump. The construction materials must meet stringent requirements. Titanium nitride was chosen for its surface properties and graphite for its bulk characteristics. The purpose of this study was to characterize the chemical vapour deposition titanium nitride coating via morphology, roughness, crystallinity, chemical composition, to report and discuss the results of in vitro haemocompatibility tests (protein adsorption, platelet retention, haemolysis) and to discuss physico-chemical and biological results. This chemical vapour deposition titanium nitride coating is well tolerated by the blood despite its surface irregularities, and appears as a good candidate material after improvements.

Absorption↗

Ex vivo leucocyte adhesion and protein adsorption on TiN.

Titanium nitride (TiN) is regarded as a potential biomaterial for blood-contact applications. Its in vitro haemocompatibility has been evaluated already and gave promising results. The purpose of this study was to continue studying its 'biological' behaviour through an ex vivo evaluation. The material was a physical vapour deposition elaborated TiN coating and the phenomena observed were leucocyte adhesion and albumin and fibrinogen adsorption. These ex vivo results were compared with in vitro results obtained previously. Two reference medical grade silicone elastomer and three TiN arterio-arterial extra-corporeal circuits were tested. No leucocyte was retained by TiN, as in in vitro experiments; the ex vivo fibrinogen adsorbed quantity was higher and albumin adsorption was about the same in in vitro and in ex vivo situations. TiN can be considered as a suitable blood-contacting material.

Adsorption↗

Blood haemolysis by ceramics.

Ceramics are more and more frequently under consideration for construction of blood-contacting devices, i.e. cardiac valves or cardiac assist devices. This study evaluated the haemolysis eventually initiated in vitro by ceramic powders (Al2O3, ZrO2/Y2O3, AlN, B4C, BN, SiC, Si3 N4, TiB2, TiN, TiC), graphite and diamond. The chemical composition of the powders was studied by X-ray microprobe and various other methods, and BET specific areas were determined. The haemolysis was almost zero for all powders, except AlN which showed slight haemolysis and TiB2 which had high haemolytic power.

Aluminum↗

Haemocompatibility of Ti6A14V alloy.

Ti6A14V alloy has been mainly used as a biomaterial in the orthopaedic field. The present study describes the surface state of the Ti6A14V material and evaluates its in vitro haemocompatibility in terms of protein adsorption, platelet retention and haemolysis. The behaviour of the Ti6A14V alloy towards albumin and fibrinogen was compared to that of a reference medical-grade elastomer. The platelet retention test gave better results than those achieved with the elastomer. The haemolysis percentage of the alloy was almost zero. These results indicate that the Ti6A14V alloy is well tolerated by blood.

Adsorption↗

Association of polyacrylamide beads to polyethylene terephthalate prostheses.

A method for the coupling of polyacrylamide beads to polyethylene terephthalate (PET) vascular prostheses is described. The reactional procedure used is performed along several steps; acrylic acid grafting on PET textile fibres, in order to introduce reactive carboxylic groups, introduction of terminal primary amine groups onto the beads, and then, attachment method which consists in coupling carboxylic groups of prostheses with amine groups of modified beads. The relative weight increase of the samples before and after the coupling reaction and, microscopic observations of beads distribution onto the prostheses surface demonstrate the binding feasibility of polyacrylamide matrices to PET prostheses. In the near future, authors expect to replace these beads by microcapsules with polyacrylamide wall and containing active compounds to improve the vascular prostheses biocompatibility.

Acrylic Resins↗

A new model to test platelet adhesion under dynamic conditions. Application to the evaluation of a titanium nitride coating.

In order to evaluate under dynamic circumstances the in vitro platelet adhesion induced by rigid materials such as ceramic coatings deposited on selected substrates, a new model simulating a tube has been designed. In vitro platelet adhesion was assessed with this new model: the material was titanium nitride (TiN) deposited on Ti6A14V (TA6V) titanium alloy by a physical vapor deposition (PVD) process. The results were compared to those obtained with complete titanium carbide (TiC) graphite tubes coated with TiN by a chemical vapor deposition (CVD) process. The difference observed (less than 25%) in favour of the new system, could be due to the better surface state of the construction materials of this system. In fact it is a systemic error. However TiN confirms its good performance as a blood-contacting biomaterial.

Alloys↗

Hemocompatibility of diamond-like carbon coating.

The new prosthetic heart valve that has been designed by FII Company and Pr. Baudet involves a new "composite" material: titanium alloy T16A14V coated with Diamond-like Carbon. The purpose of this study was to evaluate the in vitro hemocompatibility of this new material in terms of protein adsorption and platelet retention. The static protein adsorption test gave interesting results, particularly for the albumin assay (237%) compared to the results obtained with a silicone elastomer chosen as a reference; the fibrinogen quantity, adsorbed on the surface of the material was slightly higher than that adsorbed on the silicone surface. Platelets adhere quite twice as much as they do on the reference surface. Such investigations showed good hemocompatibility results and should initiate further studies.

Adsorption↗

New artificial connective matrix-like structure: thrombogenicity and use as endothelial cell culture support.

The recently described artificial connective matrix made of elastin solubilized peptides, type I+III collagens and connective proteins is shown to have structural and biological properties very close to the natural arterial subendothelium: the capacity to promote endothelial cell cultures maintaining their phenotype expression and its non-thrombogenicity. This new bioactive composite material could be used to replace arteries.

Biocompatible Materials↗

A new apheresis system using a copolymer (polyvinyl alcohol triethylene glycol diacrylate) for removal of LDL from dog whole blood.

Studies were undertaken to determine the effectiveness of a copolymer composed of PVA-TEGDA (Poly Vinyl Alcohol TriEthylene Glycol) as a plasma-cholesterol lowering procedure. For a comparative study, five dogs underwent plasmapheresis including the transfusion bag containing gel in the plasma line, while three control dogs underwent the same plasmapheresis without gel. Numerous biological determinations were performed firstly in whole blood circulation before and after treatment over 10 days, and secondly in plasma before and after LDL binding on the gel. In the whole blood circulation, the average significant depletion of cholesterol levels was 31-51% for treated, 0-16% for control dogs and the average significant depletion of LDL cholesterol was 26-75% for treated and 0-3% for control dogs. Gel was therefore able to bind 121-217 mg of total cholesterol and 34-70 mg of LDL cholesterol per gram of gel. Lipid and lipoprotein levels rebounded 3-4 days after treatment. Adverse effects were not observed during all plasmapheresis. No significant differences between control plasmapheresis and gel-plasmapheresis were obtained for blood cell counts while lengthened coagulation times were observed during 24 h. Complement was not significantly activated by the copolymer as shown by a same decreased activity in the blood stream of all dogs: in fact, CH 50 depletion in the gel incubated plasma was due to a protein adsorption on the hydrogel. This new approach for LDL apheresis appears to be a promising new technique.

Acrylic Resins↗

Cytocompatibility study of NHLBI primary reference materials using human endothelial cells.

Four different materials, low density polyethylene (LDPE), polydimethylsiloxane (PDMS), polyvinylcholoride (PVC) and cellulose, were selected by the Devices and Technology Branch of the National Heart Lung and Blood Institute (NHLBI) as primary reference materials for blood contacting. Among the wide variety of tests proposed to assess hemocompatibility of short-term blood contacting catheters, it was desirable to rule out whether these materials could release toxics for vascular cells of the physiological environment. Thus, the cytocompatibility of these materials have been checked towards human umbilical vein endothelial cells: the method used avoids direct contact between cells and materials but evaluates the effect of possible toxic substances leached from materials. These substances were obtained under defined conditions according to a standard. The results show that the extracts of cellulose and LDPE provoke an important cytotoxic effect on the endothelial cell cultures, while the extracts of PDMS and PVC allow the obtention of endothelial cell lining of the reference surface, with a correct global metabolic activity and the intracellular presence of von Willebrand factor.

Biocompatible Materials↗