Search PubMed⌕ Search

Biomedical subjects

C Aufricht

Publications and source records attributed to C Aufricht.

40 records · Page 3Linked to original sources

[Formula creatinine clearance as a substitute for 24-hour creatine clearance in children with kidney transplantation].

Despite many theoretical advantages, formula-creatininclearance (Schwartz et al, Journal of Pediatrics 1976) has not found broad clinical acceptance in everyday pediatric patient care. In this study we report our results of long term observations (11.7 +/- 6.8 (1.7-24.8) months) of measured and computed creatininclearance in 27 children after renal transplantation (15 boys, 12 girls, mean age 14.5 +/- 4.2 (5.5-20) years) at the Kinderdialyse of the Universitäts-Kinderklinik of Vienna. We found a wide scattered correlation between the measured and computed creatininclearance values with a 90% confidence interval between -30% to +60% of the 24 hour creatininclearance. Formula creatininclearance (SD 17.8%) was markedly better reproducable than the 24 hour creatininclearancethe (SD 37.8%), the intraindividuell collecting error (36.1%) was almost twice the interindividuell "coefficient" error (20.27%). We therefore conclude that the 24 hour creatininclearance is by far not as accurate as the complexity of the procedure pretends and support broad clinical acceptance for the formula creatininclearance.

Adolescent↗

Timing of peritoneal dialysis catheter removal after pediatric renal transplantation.

BACKGROUND: A peritoneal dialysis (PD) catheter is in place at the time of kidney transplantation in children receiving PD. Removal of the catheter eliminates the risk of catheter-related infections. However, the patient benefits from leaving the catheter in place if dialysis is necessary posttransplantation. There is currently no consensus on the proper timing of PD catheter removal after kidney transplantation in children. OBJECTIVE: To identify the risks and benefits of an in-dwelling PD catheter after renal transplantation in children. DESIGN: Retrospective single-center study of infectious complications and posttransplantation PD catheter use in 31 renal transplantations in 26 children. RESULTS: Peritoneal dialysis catheters were used postoperatively in 13 of the 31 transplantations. In 12 instances the catheter was needed during the first month after transplantation, and 2 of the patients involved did not have a catheter in place when needed. Six catheter-related infections occurred in 5 patients posttransplantation, with only 1 infection taking place within 1 month after transplantation. CONCLUSION: Our data suggest that the need for catheter use occurs predominantly during the first month, while infectious complications usually happen later. This strongly suggests that PD catheters should not be removed until approximately 1 month after kidney transplantation.

Adolescent↗

Estimation of total creatinine clearance is unreliable in children on peritoneal dialysis.

OBJECTIVE: To test the reliability of creatinine clearance in children on peritoneal dialysis (PD). DESIGN: Longitudinal, case-controlled. SETTING: Routine clinic visits at the pediatric dialysis unit of the Universitätskinderklinik of Vienna. PATIENTS: Eleven children (2-13 years, 10-55 kg) with end-stage renal disease on PD. INTERVENTIONS: Creatinine clearance (CCr) was determined by measuring creatinine excretion (ECr) over 24 hours in both dialysate and urine. Each child had three to five separate measurements of their CCr. At the same time we also calculated the Schwartz formula clearance from the patient's height and serum creatinine, using a modified correlate. MAIN OUTCOME MEASURES: Reliability of CCr was assessed by two approaches. First, we compared each serial measurement with the mean value for each patient and thereby assessed the "intramethodical" variability. Second, we compared each CCr with the simultaneous formula clearance and assessed the "intermethodical" disagreement. RESULTS: Twenty-seven percent of the measurements of CCr were classified as unreliable based on a comparison with the mean value for each patient. Reliability was closely correlated with residual renal function (p < 0.01); only 12% of the measurements in the anuric patients were classified as unreliable (vs 31% in the patients with residual renal function). The simultaneous formula clearance was less variable than the CCr. The formula clearance had a sensitivity of 93% and a specificity of 60% for detecting unreliable values of CCr. CONCLUSION: Estimation of total CCr is unreliable in pediatric patients on PD. A simultaneous formula clearance can be used to detect which values are unreliable.

Case-Control Studies↗