Search PubMed⌕ Search

Biomedical subjects

C A Ludlam

Publications and source records attributed to C A Ludlam.

At least 127 records · Page 7Linked to original sources

Aortic aneurysms and consumptive coagulopathy.

We describe three cases of consumptive coagulopathy caused by extensive thrombus formation in otherwise 'uncomplicated' aortic aneurysms. These cases demonstrate the importance of performing a coagulation screen in any patient presenting with thrombocytopenia who may have an aortic aneurysm. Effective therapy with low-dose heparin was demonstrated with subsequent haemostasis being maintained with warfarin.

Aged↗

Detection, quantification and sequencing of HIV-1 from the plasma of seropositive individuals and from factor VIII concentrates.

A highly sensitive and reliable RNA polymerase chain reaction method has been developed which has been used to detect, quantify and sequence cell-free HIV RNA directly from the plasma of seropositive individuals. Plasma from 10 out of 12 haemophiliacs tested was found to contain detectable levels of HIV-1 RNA [log mean value: 1.2 x 10(3) copies for Centers for Disease Control (CDC) group II patients, 5.5 x 10(3) copies for CDC group IV patients]. The presence of cell-free circulating virus in both symptomatic and asymptomatic individuals suggests that viral replication continues throughout the course of infection. The same procedure has been used to detect and sequence HIV-1 RNA in two batches of unheated commercial factor VIII concentrate distributed in 1981 and 1983. The sequences obtained revealed a closer relationship to North American than to African strains of HIV-1.

Amino Acid Sequence↗

Discontinuous sequence change of human immunodeficiency virus (HIV) type 1 env sequences in plasma viral and lymphocyte-associated proviral populations in vivo: implications for models of HIV pathogenesis.

Sequence change in different hypervariable regions of the external membrane glycoprotein (gp120) of human immunodeficiency virus type 1 (HIV-1) was studied. Viral RNA associated with cell-free virus particles circulating in plasma and proviral DNA present in HIV-infected peripheral blood mononuclear cells (PBMCs) were extracted from blood samples of two currently asymptomatic hemophiliac patients over a 5-year period. HIV sequences were amplified by polymerase chain reaction to allow analysis in the V3, V4, and V5 hypervariable regions of gp120. Rapid sequence change, consisting of regular replacements by a succession of distinct viral populations, was found in both plasma virus and PBMC provirus populations. Significant differences between the frequencies of sequence variants in DNA and RNA populations within the same sample were observed, indicating that at any one time point, the predominant plasma virus variants were antigenically distinct from viruses encoded by HIV DNA sequences in PBMCs. How these findings contribute to current models of HIV pathogenesis is discussed.

Acquired Immunodeficiency Syndrome↗

An unusual case of amyloidosis complicating light chain myeloma.

We present an unusual case of light chain myeloma complicated by systemic amyloidosis. There was massive infiltration of the left iliopsoas and quadratus femoris muscles with amyloid, manifesting itself clinically as a progressive, painless limp. We point out that accurate diagnosis by muscle biopsy in such cases has important prognostic implications and may avoid the unnecessary use of potentially toxic and ineffective treatment.

Aged↗

Hepatitis C quantification and sequencing in blood products, haemophiliacs, and drug users.

The polymerase chain reaction (PCR) detected specific hepatitis C viral (HCV) RNA sequences in plasma from 15 of 21 haemophiliacs (12 HCV-antibody positive) and 7 of 27 intravenous drug users (13 HCV-antibody positive). Quantification of RNA-positive samples showed high levels of HCV (10(5) to 10(6) copies of RNA/ml) in infected patients. HCV was more frequently found in haemophiliacs infected with human immunodeficiency virus (11/11 HIV-positive and 4/10 HIV-negative patients). HCV-RNA was detected in all batches of commercially available factor VIII tested and in low concentrations in some pools of plasma donations from volunteers. Factor VIII, manufactured from volunteer donations, was uniformly negative by PCR. Phylogenetic analysis of viral sequences showed two distinct groups: one was associated with intravenous drug users and the other with haemophiliacs infected with Scottish factor VIII preparations. Both were distinct from sequences found in commercially available factor VIII.

Acquired Immunodeficiency Syndrome↗

Five year prospective study of HIV infection in the Edinburgh haemophiliac cohort.

OBJECTIVE: To identify measures of immune state that reflect the course of HIV related disease in order to predict deterioration of symptoms and assess response to treatment. DESIGN: Five year longitudinal clinical and laboratory study. SETTING: Regional haemophilia centre, university virology laboratory, and Medical Research Council laboratory. PATIENTS: 32 Patients with haemophilia A exposed to a single batch of HIV contaminated factor VIII concentrate from the Scottish National Blood Transfusion Service in 1984 who were followed up regularly in Edinburgh (31) or abroad (one). MAIN OUTCOME MEASURES: Counts of circulating T cell subsets (CD4 and CD8); plasma beta 2 microglobulin, neopterin, and IgA concentrations; and delayed type hypersensitivity to multiple skin test antigens. RESULTS: 18 Patients who seroconverted after exposure had received significantly more contaminated factor VIII than the 14 who did not (mean 43 (range 9-109) v 15 (3-30) phials, p less than 0.01). The two groups were not distinguishable by other criteria before exposure. The group that seroconverted subsequently showed a progressive fall in mean circulating CD4 lymphocytes and an increase in plasma beta 2 microglobulin and neopterin concentrations. From 1987 patients in this group also showed an increase in mean circulating CD8 lymphocytes and in plasma IgA concentration, neither of which was seen in patients who did not seroconvert. Patients with HIV antibody who developed Centers for Disease Control category IV symptoms within five years after infection showed more extreme changes in all measures, except CD8 lymphocyte count, than those whose symptoms remained in categories II and III. Skin test reactivity declined to barely detectable levels in all patients positive for HIV antibody. CONCLUSIONS: Serial estimates of circulating CD4 lymphocytes and of plasma beta 2 microglobulin concentration are the most reliable measures of disease progression; of these, beta 2 microglobulin concentration seems to be the better predictor of impending serious symptoms. High IgA concentrations reflect rather than predict disease state. Individual variation in most measures is such that a wide range of measurements should be used in assessing the effects of trial treatment in HIV infected patients without symptoms.

Adolescent↗

Analysis of sequence diversity in hypervariable regions of the external glycoprotein of human immunodeficiency virus type 1.

Nucleotide sequences in three hypervariable regions of the human immunodeficiency virus type 1 (HIV-1) env gene were obtained by sequencing provirus present in peripheral blood mononuclear cells of HIV-infected individuals. Single molecules of target sequences were isolated by limiting dilution and amplified in two stages by the polymerase chain reaction, using nested primers. The product was directly sequenced to avoid errors introduced by Taq polymerase during the amplification process. There was extensive variation between sequences from the same individual as well as between sequences from different individuals. Interpatient variability was markedly less in individuals infected from a common source. A high proportion of amino acid substitutions in the hypervariable regions altered the number and positions of potential N-linked glycosylation sites. Sequences in two hypervariable regions frequently contained short (3- to 15-bp) duplications or deletions, and by amplifying peripheral blood mononuclear cell DNA containing 10(2) or 10(3) proviral molecules and analyzing the product by high-resolution electrophoresis, the total number and abundance of distinct length variants within an individual could be estimated, providing a more comprehensive analysis of the variants present than would be obtained by sequencing alone. Sequences from many individuals showed frequent amino acid substitutions at certain key positions for neutralizing-antibody and cytotoxic T-cell recognition in the immunodominant loop. The rates of synonymous and nonsynonymous nucleotide substitution in the region of this and flanking regions indicate that strong positive selection for amino acid change is operating in the generation of antigenic diversity.

Amino Acid Sequence↗

Concurrent evolution of human immunodeficiency virus type 1 in patients infected from the same source: rate of sequence change and low frequency of inactivating mutations.

Direct sequencing of segments of the envelope gene of human immunodeficiency virus type 1 proviruses in peripheral blood mononuclear cells has revealed that a cohort of hemophiliacs who were infected after exposure to a single common batch of factor VIII share closely related virus strains. Seventy-four sequences extending from hypervariable regions V4 through V5 from nine patients yielded a mean intrapatient nucleotide distance of 5.5%, while a mean of 4.2% was observed in 39 sequences of the V3 loop (six patients). Phylogenetic analysis revealed that sequences of six Edinburgh patients were particularly closely related and those from a patient infected in the United States were very distinct. The mean nucleotide distance among these six was 8.3%, while the mean distance from the U.S.-derived sequences was 25.5% in the V4-V5 region. The rate of sequence change across this patient group has been estimated to be 0.4% per year in the V4-V5 region and 0.5% per year in the V3 region, with at least a twofold range across patients. Only two inactivating nucleotide substitutions have been observed in a total of 42 kb of sequence obtained from the env and gag genes during this study.

Base Sequence↗

Human immunodeficiency virus-infected individuals contain provirus in small numbers of peripheral mononuclear cells and at low copy numbers.

In human immunodeficiency virus (HIV)-infected individuals, the proportion of circulating mononuclear cells (PBMCs) which carry HIV provirus and the number of HIV proviral sequences per infected PBMC have been matters for conjecture. Using a double polymerase chain reaction which allows the detection of single molecules of provirus and a method of quantifying the provirus molecules, we have measured provirus frequencies in infected individuals down to a level of one molecule per 10(6) PBMCs. As a general rule, only a small proportion of PBMCs contain provirus (median value of samples from 12 patients, one per 8,000 cells), and most if not all of the infected cells carry a single provirus molecule. The frequency of provirus-carrying cells correlated positively both with the progression of the disease and with the success with which virus could be isolated from the same patients by cocultivation methods. Of seven asymptomatic (Centers for Disease Control stage II) patients, all but one contained one provirus molecule per 6,000 to 80,000 cells; of five Centers for Disease Control stage IV patients, all but one contained one provirus molecule per 700 to 3,300 cells. When considered in conjunction with estimates of the frequency of PBMCs that express viral RNA, our results suggest that either (i) the majority of provirus-containing cells are monocytes or (ii) most provirus-containing lymphocytes are transcriptionally inactive. We also present nucleotide sequence data derived directly from provirus present in vivo which we show is not marred by the in vitro selection of potential virus variants or by errors introduced by Taq polymerase. We argue from these data that, of the provirus present in infected individuals, the proportion which is defective is not high in the regions sequenced.

Base Sequence↗

Human immunodeficiency virus detection: correlation with clinical progression in the Edinburgh haemophiliac cohort.

HIV p24 antigenaemia and virus detection in cultures of peripheral blood lymphocytes were examined in 16 of 18 haemophiliacs infected with HIV by a single batch of Scottish National Blood Transfusion Service factor VIII concentrate. Six (38%) had p24 antigenaemia and 11 (69%) had positive lymphocyte cultures. All seven patients with serious HIV disease (CDC group IV) had positive lymphocyte cultures whereas four (57%) had p24 antigenaemia. Four of nine (44%) patients with asymptomatic HIV disease (CDC groups II and III) had positive cultures and two (22%) had p24 antigenaemia. Twenty-eight of 36 samples from the symptomatic group were HIV culture positive compared with nine of 30 samples from the asymptomatic group (P less than 0.001). None of 14 antibody negative haemophiliacs who also received the implicated batch of factor VIII had p24 antigenaemia or positive HIV cultures. The ability to detect HIV in cultured lymphocytes correlates with the clinical severity of HIV disease in this cohort.

AIDS Serodiagnosis↗

HLA haplotype A1 B8 DR3 as a risk factor for HIV-related disease.

Of 32 patients exposed to a single batch of factor VIII contaminated with human immunodeficiency virus (HIV), 18 became antibody positive. Serial T cell subset analyses over the succeeding four years have shown a progressive decline in circulating T4 cells in those 18 but no change in the 14 who remain seronegative. 2 of the seroconverters have died and a further 7 have symptoms attributable to HIV infection. In the group as a whole, the HLA haplotype A1 B8 DR3 was weakly associated with an increased risk of seroconversion on exposure to the virus while, in those who seroconverted, it was strongly associated with a rapid decline in T4 cells and development of HIV-related symptoms within four years of infection.

Adult↗

HIV antigen and antibody detection: variable responses to infection in the Edinburgh haemophiliac cohort.

Sequential serum samples from 18 haemophiliac patients exposed simultaneously to human immunodeficiency virus type 1 (HIV 1) in early 1984 were tested retrospectively for serological markers of infection. Assay for total antibodies to HIV established that the time to seroconversion might be as long as 110 days after exposure to contaminated factor VIII; serum samples were also tested by Western blotting, by enzyme linked immunosorbent assay (ELISA) for specific antibodies to envelope and core proteins, and for p24 antigen by two assay systems during the two years after infection. The studies showed that five of the 12 patients for whom serum samples obtained between exposure and seroconversion were available had transient p24 antigenaemia. Although amounts of total antibody to HIV and of antibodies to envelope proteins rose continuously during the two years of the study, amounts of antibody to the core protein were variable and tended to decline in patients who became symptomatic. Two patients had persistent p24 antigenaemia that began four months after seroconversion; these patients remained asymptomatic. One patient who developed the acquired immune deficiency syndrome (AIDS) had transient antigenaemia at the time of seroconversion but failed to show any antigen for the rest of the study; progression to AIDS was accompanied by an increase in antibodies to envelope proteins. Much of the variability in the course of infection with HIV must represent the differences in the susceptibility of the patients to infection.

Acquired Immunodeficiency Syndrome↗