Search PubMed⌕ Search

Biomedical subjects

C A Fente

Publications and source records attributed to C A Fente.

8 recordsLinked to original sources

Determination of quinolones in animal tissues and eggs by high-performance liquid chromatography with photodiode-array detection.

A rapid, specific reversed-phase HPLC method is described, with solid-phase extraction, for assaying five quinolones (ciprofloxacin, difloxacin, enrofloxacin, norfloxacin and marbofloxacin) with confirmative diode-array detection in samples of bovine kidney, muscle and eggs. The least efficient extraction was marbofloxacin from kidney tissue (64%). The lower detection limit for each quinolone was: enrofloxacin and ciprofloxacin, 1 ng; norfloxacin and difloxacin, 2 ng; marbofloxacin, 4 ng injected. The intra-day relative standard deviations were lower than 7.9% and lower than 8.6% for inter-day assays. These results indicate that the developed method had an acceptable precision.

4-Quinolones↗

Determination of clenbuterol residues in bovine hair by using diphasic dialysis and gas chromatography-mass spectrometry.

A method for the determination of clenbuterol (4-amino-3,5-dichloro-alpha[(tert.-butylamino)methyl]-benzyl alcohol hydrochloride) in hair of living cows has been developed. Hair samples were digested in an alkaline medium. The diphasic dialysis technique is a semi-permeable membrane technology developed for the direct extraction of relatively low-molecular-mass analytes such as clenbuterol. In this case, we used sodium citrate buffer to homogenize the digested hair, dichloromethane was used as the extraction solvent at 37 degrees C, and stirring was applied at 150 rpm for 4 h. The analysis was carried out using gas chromatography-mass spectrometry. The calibration curve for clenbuterol in hair was linear in the range from 12.5 to 400 ng g(-1). The detection limit of clenbuterol was 5 ng g(-1) and the quantification limit was 12.5 ng g(-1), in hair. A good inter-day reproducibility was obtained (R.S.D. = 7.08%). The repeatability and intra-day reproducibility (50 ng g(-1) of hair, n = 10) show R.S.D.s of 7.1 and 9.5%, respectively.

Animals↗

Determination of dexamethasone in bovine liver by chemiluminescence high-performance liquid chromatography.

A new method for the determination of dexamethasone (9alpha-fluoro-11beta,17alpha,21-trihydroxy-16alpha -methylpregna-1, 4-diene-3,20-dione) in bovine liver was developed. This new liquid-liquid extraction method comprises the addition of sodium hydroxide to the tissue sample followed by extraction with ethyl acetate. After centrifugation, the extract is evaporated to dryness and the residue dissolved in acetonitrile. The cleaning of the fat is performed with n-hexane, and the acetonitrile layer is evaporated. Analysis of the extracts is performed using high-performance liquid chromatography with chemiluminescence detection employing luminol as CL reagent. A series of recovery curves performed at spiking levels of 50, 30, 10, 5, and 2.5 ppb show that at least 80% of DEX can be recovered from liver and that the chemiluminescence detection yields satisfactory results with respect to sensitivity (LOD 0.2 ppb), reproducibility (CV% 10.7) and repeatability (CV% 6.2-8.9).

Animals↗

Interaction between cyclodextrins and aflatoxins Q1, M1 and P1. Fluorescence and chromatographic studies.

The fluorescence properties of the aflatoxins M1, Q1, P1 in solution and the effect of various cyclodextrins (alpha-, beta-, gamma-, hydroxypropyl-beta- and alpha-beta-heptakis-di-O-methyl-beta-) on their fluorescence emission were studied. Among the aflatoxins, a substantial enhancement of the fluorescence emission of aflatoxin Q1 in the presence of aqueous solutions of alpha-, beta-, hydroxypropyl-beta, and alpha-beta-heptakis-di-O-methyl-beta-cyclodextrin, was observed. On the contrary, gamma-cyclodextrin proved to be inefficient to enhance the fluorescence properties of this compound. No important fluorescence enhancement was found for aflatoxins P1 or M1 for any of the cyclodextrin derivatives tested. The complex formation constant (Kf) of these compounds with beta-cyclodextrin was chromatographically determined, and from the results obtained, we can conclude that Kf cannot be used alone to explain the fluorescence increase. Thermodynamic studies showed that delta-H and delta-S parameters, associated with the partition of aflatoxins in RP-HPLC, increased when beta-cyclodextrin was added to the eluent.

Aflatoxin M1↗

Determination of alternariol in tomato paste using solid phase extraction and high-performance liquid chromatography with fluorescence detection.

Alternaria spp. produce a wide variety of toxic metabolites with different chemical structures. Tomato products have been considered a likely source of Alternaria toxins in the human diet because Alternaria is an important spoilage mold of tomatoes. A new method for the determination of these mycotoxins in tomato paste, involving solid phase cartridges for extraction before HPLC fluorescence detection with a reversed phase column and isocratic elution, was developed. The method was demonstrated to be linear in the range 5.2-196 ppb of alternariol (AOH) in tomato paste. Good recoveries were obtained for AOH at all levels assayed (minimum 77.2%). The detection limit of the AOH toxin in real samples of tomato paste was low, 1.93 ppb. The precision of the method was demonstrated with a good repeatability (RSD = 2.98%) and reproducibility (RSD = 9.35%).

Calibration↗

Determination of residues of the beta-agonist clenbuterol in liver of medicated farm animals by gas chromatography-mass spectrometry using diphasic dialysis as an extraction procedure.

A method has been developed for the rapid confirmation of clenbuterol in cow liver using gas chromatography coupled with detection by mass spectrometry of the trimethylsilyl derivatives of clenbuterol. The technique used for the extraction was diphasic dialysis. It was observed that the best suitable solution to homogenize the liver the barium hydroxide-barium chloride buffer, the optimal extraction solvent was tert.-butylmethyl ether at an extraction temperature of 37 degrees C, and stirring should be applied at 150 rpm for 4 h. This extraction method improves clenbuterol recovery up to values of 99.3%. With the use of the barium buffer, derivatization is performed more efficiently and the detection and quantification limits can be decreased to values close to 250 ppt and 500 ppt, respectively.

Adrenergic beta-Agonists↗

Simple and sensitive high-performance liquid chromatography--fluorescence method for the determination of citrinin application to the analysis of fungal cultures and cheese extracts.

A new and highly sensitive method for the detection of the important mycotoxin, citrinin, has been developed. Spectroscopic studies demonstrate that the fluorescence of this metabolite is influenced by the pH of the environment. This fact was exploited in the chromatographic determination of citrinin with fluorescence detection. The proposed method, based on the addition of 1 M hydrochloric acid as an acidic post-column reagent, has a limit of detection of 0.9 center dot 10(-7) M. Analytical validation shows that linearity can be assumed from 2 center dot 10(-7) to 10(-4) M citrinin. The repeatability and reproducibility are satisfactory, with R.S.D. = 5.1% (n = 9, c = 10(-5) M) and R.S.D. = 7.2% (n = 9, c = 10(-5) M). The method was also applied to the determination of this mycotoxin produced by mould cultures isolated from soft cheese and also from soft cheese and also from cheese extracts spiked with citrinin. The specificity of the method is demonstrated and the necessity for post-column acidification is illustrated on real samples.

Cheese↗

Postcolumn excitation of aflatoxins using cyclodextrins in liquid chromatography for food analysis.

Measurement of fluorescence increase was used for the comparative quantification of the effect that several cyclodextrins (alpha-, beta-, heptakis-2,6-beta-omicron-dimethyl- and gamma-) produce on the fluorescent response of aflatoxins B1 and G1. This constitutes a new chromatographic method with stability of the mobile phase, and shows general improvements in the chromatographic conditions with respect to other methods (especially those using an iodine reservoir as a postcolumn reactor). A C18-type column was used, with methanol-water (60:40, v/v) as the mobile phase. The excitation phase of the natural fluorescence of aflatoxins, a 10(-2) M solution of each cyclodextrin, was introduced postcolumn. The determination of the elution order aflatoxin G2 > G1 > B2 > B1 was performed for each phase in less than 15 min. As expected using an aqueous-alcoholic medium, an increase in the fluorescence response of aflatoxins with an unsaturated furanic ring was found to occur with all the cyclodextrins studied, except gamma-cyclodextrin. The observed increase was larger for heptakis-2,6-beta-omicron-dimethyl- than for beta-cyclodextrin (to our knowledge, the only cyclodextrin previously described in the literature to serve for the determination of aflatoxins). The difference is of the order of 70.1-fold in the case of aflatoxin G1 and 45.2-fold in the case of aflatoxin B1. The detection limit in the mobile phase used was determined (for aflatoxin B1) for beta-cyclodextrin and 2,6-beta-omicron-dimethylcyclodextrin (signal-to-noise ratio 1:3) to be 4 and 9 mg 1(-1), respectively.

Aflatoxin B1↗