The effect of temperature and wavelength on the measurement of creatinine with the Jaffe procedure.

Studies were conducted to determine the effect of temperature and wavelength on the absorbance of alkaline solutions of picric acid in the presence and absence of creatinine. Absorbance values of an alkaline solution of picric acid were found to be influenced by temperature. At wavelength settings between 475 and 520 nm, absorbance values increased as the temperature increased. The magnitude of the thermochromic response (temperature-induced increase in absorbance) was found to be a function of wavelength: At 490 nm, the response was about three times greater than it was at 500 nm and about fifteen times greater than it was at 520 nm. Other experiments demonstrated that the response was: quantitatively related to picric acid concentration, reversible, rapid, and independent of creatinine concentration.

Creatinine↗

Relative stabilities of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase in lyophilized materials.

Eight different pools of purified human mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase were prepared, to examine the effects of the following matrix variables: the matrix support material (bovine serum albumin and polyvinylpyrrolidone), endogenous pyridoxal concentration, and azide as an antimicrobial preservation. Storage temperatures of 25 and 37 degrees C were used as a rapid and convenient means of accelerating the degradation process. Activity of the enzyme was measured with and without pyridoxal in the reaction solution. We found that the mitochondrial isoenzyme was consistently more labile than the cytoplasmic isoenzyme under identical storage conditions. Both isoenzymes were more stable in matrixes containing bovine serum albumin than in those containing polyvinylpyrrolidone. No apparent difference in the stability of either isoenzyme was observed at matrix pyridoxal concentrations of 15 micromol/L and 150 micromol/L. Only the mitochondrial isoenzyme in matrixes containing bovine serum albumin and 15 micromol of pyridoxal per liter had increased activity (about 9%) when pyridoxal was added to the enzymatic reagent. The amount of activity in reconstituted specimens did not apparently change after 72 h at 4 degrees C.

Aspartate Aminotransferases↗

Column chromatography and immunoassay compared for measuring the isoenzymes of aspartate aminotransferase in serum.

We compare a column-chromatographic method and a homogeneous immunoassay method for separately measuring the mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase. Analytical recovery for the two methods averaged 102% (SD, 2%) and 103% (SD, 4%), respectively, for 11 pools prepared by adding the purified isoenzymes to serum and 102% (SD 8.9%) and 89% (SD, 8.1%) for 26 unaltered specimens of human serum. In comparing the results of the immunoassay method (y) to the chromatographic method (x), our measurements agreed closely for the mitochondrial (y = 0.947 X + 7, r = 0.9991, standard error of estimate = 2.9 U/L) and cytoplasmic (y = 0.92x-6, r = 0.9995, standard error of estimate = 2.1 U/L) isoenzymes in pools prepared from the purified isoenzymes. Similar measurements of the 26 human serum specimens yielded the following results for least-squares evaluation; cytoplasmic isoenzyme y = 1.03x-11, r = 0.994, and standard error of estimate = 6.0 U/L; mitochondrial isoenzyme y = 0.75x+0, r = 0.927, and standard error of estimate = 3.9 U/L.

Aspartate Aminotransferases↗

Effects of carcinogenic and non-carcinogenic chemicals on plasma esterases in BALB/c mice.

Esterase profiles of plasma from female BALB/c mice treated with a variety of carcinogenic and weakly- or non-carcinogenic chemicals were analyzed. Mice treated with the potent carcinogens diethylnitrosamine, dinitrosopiperazine, dipropylnitrosamine, dimethylhydrazine, urethane, and dimethyldinitrosopiperazine had similarly altered plasma esterase profiles after 7 days' exposure to the chemicals. The alterations consisted of increased activity in 4 esterase bands. The increased activity persisted in some of the bands after cessation of carcinogen exposure. Exposure to high concentrations of the weakly- or non-carcinogenic compounds nitrosohydroxyproline, nitrosomethoxymethylamine, 1-nitroso-4methylpiperazine,nitroso-2,6dimethylpiperidine, and ethyl methanesulfonate caused no obvious plasma esterase alterations. Ingestion of carbon tetrachloride resulted in increased activity in one esterase band with concomitant decrease in a second band. Analysis of serum from test mice for levels of serum glutamic oxaloacetic transaminase, alkaline phosphatase, lactate dehydrogenase-lactate substrate, and D-gamma-glutamyl transpeptidase did not differentiate between mice treated with selected carcinogens and those treated with non-carcinogens and/or carbon tetrachloride.

Animals↗

Column-chromatographic separation of isoenzymes of aspartate aminotransferase.

We describe a column-chromatographic method for separating the mitochondrial and cytoplasmic isoenzymes of aspartate aminotransferase in human serum. Bed height of the ion exchanger, pH, and salt concentrations in the eluting buffers are shown to be variables affecting the separation of the isoenzymes. Under the optimized conditions selected for this study, a 30% increase in volume was observed in one fraction, associated with changing the salt concentration of the eluting buffer and attributed to a contraction of the DEAE-Sephadex A-50. Elution profiles (enzyme activity vs. fraction number) were examined with highly purified mitochondrial and cytoplasmic isoenzymes of human origin in bovine serum albumin and human serum. Recovery of the enzyme in the eluted fractions averaged 102% (SD, 2.0%) for specimens prepared from the purified isoenzymes and 104% (SD, 10.7%) for 38 human serum specimens. The separation technique showed linearity to catalytic concentrations in excess of 200 U/liter (reaction temperature 30 degrees C) for each isoenzyme. Additional information is presented regarding among-day precision and the effect of specimen dilution.

Aspartate Aminotransferases↗

An interlaboratory study of measurement of aspartate aminotransferase activity with use of purified enzyme materials.

The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared and characterized and then distributed to 293 laboratories for aspartate aminotransferase measurements. The specimens included one human serum; four catalytic concentrations of the cytoplasmic isoenzyme, two purified from human erythrocytes, and two from porcine heart; and one matrix bovine serum albumin (30 g/liter) blank. The purified isoenzymes were prepared in the matrix. We present data on Michaelis parameters (Km and Vmax), Arrhenius plots, activation with pyridoxal 5-phosphate, vial-to-vial variability, and stability on reconstitution. The 281 responses showed that most of the laboratories used NADH-detection methods (91.1%), monitored at 340 nm (79.4%), and reported results in U/liter (89.4%). The percentage of laboratories reporting use of reaction temperatures of 30 and 37 degrees C was evenly divided, i.e., 42.7 and 42%, respectively. Analytical values reported by participating laboratories were categorized by reporting temperature, instrument, and method. Results were most consistent for a selected group of laboratories that supplemented optimized reaction solutions with pyridoxal 5-phosphate.

Aspartate Aminotransferases↗

Temperature dependence of the absorbance of alkaline solutions of 4-nitrophenyl phosphate--a potential source of error in the measurement of alkaline phosphatase activity.

The absorbance of an alkaline solution of 4-nitrophenyl phosphate is a function of temperature. Quantitative evaluation of this phenomenon indicates that it (a) depends on the concentration of the compound and is independent of source, buffer concentration, and pH above 9.0; (b) is reversible; (c) is not a result of alkaline hydrolysis or 4-nitrophenol contamination; and (d) correlates with a temperature-induced shift of its absorbance spectrum. The phenomenon may represent a potential analytical problem in methods for alkaline phosphatase in which this compound is the substrate. If thermal equilibrium is not reached and maintained during an alkaline phosphatase assay, the thermochromic response will be included in the measured rate. The magnitude of this error depends on the thermal response and control characteristics of each particular instrument and the reaction conditions under which such an analysis is performed.

Alkaline Phosphatase↗

4-Nitrophenol in 4-nitrophenyl phosphate, a substrate for alkaline phosphatase, as measured by paired-ion high-performance liquid chromatography.

We used paired-ion high-performance liquid chromatography to determine the 4-nitrophenol content of 4-nitrophenyl phosphate, a substrate for alkaline phosphatase analysis. This was done on a reversed-phase column with a mobile phase of methanol/water, 45/55 by vol, containing 3 ml of tetrabutylammonium phosphate reagent per 200 ml of solvent. At a flow rate of 1 ml/min, 4-nitrophenol was eluted at 9 min and monitored at 404 nm; 4-nitrophenyl phosphate was eluted at 5 min and could be monitored at 311 nm. Samples of 4-nitrophenyl phosphate obtained from several sources contained 0.3 to 7.8 mole of 4-nitrophenol per mole of 4-nitrophenyl phosphate.

4-Nitrophenylphosphatase↗

Development of a multipurpose optical system for use with a centrifugal fast analyzer.

A Centrifugal Fast Analyzer is basically a sophisticated photometric measuring device containing a multicuvet rotor as its major component. Several reactions are simultaneously initiated in the rotor, which is then rotated through a stationary optical monitor and the resulting signals acquired and processed by an on-line data system. ?With the miniature version of this analyzer, one has the option of directing the incident optical beam, via a fiber optical bundle, into the cuvets of the spinning rotor in either a 90 degrees or a 180 degrees orientation relative to the analyzer's photodetector. tthe combination of newly designed rotors and a flexible optical system having multiple configurations has provided a versatile system in which one can measure the transmittance, fluorescence, chemiluminescence, or light-scattering (either turbidimetrically or nephelometrically) properties of the ensuing reaction species, all with a single analyzer. This flexibility in choosing the optical mode in which a particular set of reactions is to be monitored provides the analyst with a powerful and versatile analytical tool for developing new methods for use in various clinical laboratory applications, including chemistry, toxicology, immunology, and hematology.

Autoanalysis↗

Coagulation-time determination with automatic multivariable analysis, by use of a miniature centrifugal fast analyzer.

Use of a miniature Centrifugal Fast Analyzer for the parallel photometric monitoring of the coagulation process is shown to have a number of advantages. These include a choice of optical modes, virtually simultaneous initiation and observation of the coagulation process for a number of patient-plasma samples and an on-board control sample, small sample and reagent volume requirements, and automatic determination of a number of diagnostically useful variables (including relative fibrinogen content) from the data recorded in a single run. Also, the system is shown to give results that correlate well with those obtained by conventional techniques for determination of prothrombin time.

Autoanalysis↗

Factors influencing evaporation from sample cups and assessment of their effect on analytical error.

We studied sample evaporation and its effect on analytical error. Several factors influencing evaporative loss have been identified and measured: environmental, instrumental, and operational factors, and the chemical and physical properties of the sample and its container. Such losses from several different types of sample cups have been measured, either chemically or gravimetrically, and compared with those calculated by using a model that allows evaporative loss from a cup of known geometry to be predicted under various environmental conditions. We discuss some steps that may be taken to minimize evaporative loss and give an example to demonstrate that analytical error from this source can be decreased to a routine 1--2% or less by selecting a particular cup design.

Analysis of Variance↗