Simple sequential injection analysis systems with a dynamic surface tension detector.

Simple sequential injection analysis systems with DSTD (SIA/DSTD) have been developed. One was employed for the study of the effects of the ion contents in solutions to the dynamic surface pressure of ionic surfactants. The results from the studies show the possibility for an alternative simple fast screening, but also a sensitive procedure for water quality determination. Another simple SIA/DSTD system has been demonstrated for the quantification of an anionic surfactant using a single standard calibration.

Calibration↗

Evaluation of the DotMap algorithm for locating analytes of interest based on mass spectral similarity in data collected using comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry.

Comprehensive two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC x GC-TOF-MS) is a highly selective technique ideal for the analysis of complex mixtures. The instrument yields an abundance of data, with complete mass spectral scans at every time point in the GC x GC separation space. The development and application of appropriate tools for data mining is essential in making sense of the wealth of information available. An algorithm for locating analytes of interest based on mass spectral similarity in GC x GC-TOF-MS data, called DotMap, has been previously reported and is rigorously evaluated herein. A thorough investigation into the performance characteristics of DotMap, including the performance near the limit of detection and dynamic range of the algorithm as well as the capacity of the algorithm to deal with peak overlap, is investigated using jet fuel as a complex sample matrix. For instance, the algorithm can successfully identify a spiked compound at the single microg/ml level in a jet fuel sample with an overlapping interferent. The performance of the DotMap algorithm in situations with very limited mass spectral selectivity, specifically in the evaluation of spectra from isomer compounds, as well as the ability to tune DotMap results to provide the location of a specific analyte or of a class of compounds is demonstrated. The DotMap algorithm is demonstrated to be a sensitive tool that is useful in the analysis of complex mixtures and which possesses the capacity to be easily "tuned" to discern the location of analytes of interest.

Algorithms↗

Algorithm for locating analytes of interest based on mass spectral similarity in GC x GC-TOF-MS data: analysis of metabolites in human infant urine.

The developed algorithm reported herein, referred to as "DotMap," addresses the need to rapidly identify analyte peak locations in gas chromatography x gas chromatography-time of flight mass spectrometry (GC x GC-TOF-MS) data. The third-order structure of GC x GC-TOF-MS data is such that at each point in the GC x GC chromatogram, a complete mass spectrum is measured. DotMap utilizes this third-order structure to search for the location of a given spectrum of interest in a complete data set, or in a user selected portion of the complete data set. The algorithm returns a contour plot indicating the location of signal(s) with the most similar mass spectra to the analyte of interest. A spectrum from the region indicated is then subjected to an automated mass spectral search to give immediate feedback on the accuracy of the analysis. This algorithm was investigated with a trimethylsilyl (TMS) derivatized human infant urine sample that contained organic acid metabolites. One hundred percent of 12 selected TMS derivatized organic acid metabolites in human infant urine were located with the DotMap algorithm. A typical automated DotMap analysis takes 30 s on a 1.6 GHz PC with 1024 MB of RAM. Vanillic acid (TMS) was located by DotMap, but also exhibited overlap with other organic acids. The presence of vanillic acid (TMS) was confirmed by subjecting the appropriate GC x GC region to chemometric signal deconvolution by PARAFAC to yield pure component information suitable for subsequent quantification.

Algorithms↗

Multivariate selectivity as a metric for evaluating comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry subjected to chemometric peak deconvolution.

Two-dimensional gas chromatography (GC x GC) coupled to time-of-flight mass spectrometry (TOFMS) [GC x GC-TOFMS)] is a highly selective technique well suited to analyzing complex mixtures. The data generated is information-rich, making it applicable to multivariate quantitative analysis and pattern recognition. One separation on a GC x GC-TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this report, we demonstrate how GC x GC-TOFMS combined with trilinear chemometric techniques, specifically parallel factor analysis (PARAFAC) initiated by trilinear decomposition (TLD), results in a powerful analytical methodology for multivariate deconvolution. Using PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified without requiring a standard data set, signal shape assumptions or any fully selective mass signals. A set of four isomers (iso-butyl, sec-butyl, tert-butyl, and n-butyl benzenes) is used to investigate the practical limitations of PARAFAC for the deconvolution of isomers at varying degrees of chromatographic resolution and mass spectral selectivity. In this report, multivariate selectivity was tested as a metric for evaluating GC x GC-TOFMS data that is subjected to PARAFAC peak deconvolution. It was found that deconvolution results were best with multivariate selectivities over 0.18. Furthermore, the application of GC x GC-TOFMS followed by TLD/PARAFAC is demonstrated for a plant metabolite sample. A region of GC x GC-TOFMS data from a complex natural sample of a derivatized metabolic plant extract from Huilmo (Sisyrinchium striatum) was analyzed using TLD/PARAFAC, demonstrating the utility of this analytical technique on a natural sample containing overlapped analytes without selective ions or peak shape assumptions.

Evaluation Studies as Topic↗

High-speed gas chromatography using synchronized dual-valve injection.

A novel injection technique for high-speed gas chromatography is demonstrated. Synchronized dual-valve injection is shown to provide peak widths as low as 1.5 ms (width at half-height) for an unretained analyte. This was achieved using a 0.5-m DB-5 column with an internal diameter of 100 microm and a film thickness of 0.4 microm operated at a temperature of 150 degrees C with a column absolute head pressure of 85 psi, resulting in a dead time of only t(o) = 26 ms ( approximately 1900 cm/s, 26 mL/min). Using the DB-5 column in a 1-m length under the same instrumental parameters, with a resulting linear flow velocity of 935 cm/s (12.7 mL/min, t(o) = 117 ms), a minimum peak width of 3.3 ms was obtained. During an isothermal separation, 10 analytes were separated in a time window of 400 ms. A rigorous comparison of experimental and theoretical band-broadening data based on the Golay equation showed that band broadening is limited almost entirely by the chromatographic band broadening terms expressed by the Golay equation and not by extra column band broadening due to the injection process. Synchronized dual-valve injection offers a rugged and inexpensive design, providing extremely reproducible injections with peak height precision of 2.4% (RSD) and low run-to-run variation in retention times, with an average standard deviation less than 0.1 ms. Herein, synchronized dual-valve injection is demonstrated as a proof of principle using high-speed diaphragm valves. It is foreseen that the injection technique could be readily implemented using a combination of thermal modulation and high-speed valve hardware, thus optimizing the mass transfer and not significantly sacrificing the limit of detection performance for high-speed GC. Further implications are that, if properly implemented, high-speed temperature programming coupled with this new technology should lead to very large peak capacities for approximately 1-s separations.

Chromatography, Gas↗

Trilinear chemometric analysis of two-dimensional comprehensive gas chromatography-time-of-flight mass spectrometry data.

Two-dimensional comprehensive gas chromatography (GC x GC) is a powerful instrumental tool in its own right that can be used to analyze complex mixtures, generating selective data that is applicable to multivariate quantitative analysis and pattern recognition. It has been recently demonstrated that by coupling GC x GC to time-of-flight mass spectrometry (TOFMS), a highly selective technique is produced. One separation on a GC x GC/TOFMS provides retention times on two chromatographic columns and a complete mass spectrum for each component within the mixture. In this manuscript, we demonstrate how the selectivity of GC x GC/TOFMS combined with trilinear chemometric techniques such as trilinear decomposition (TLD) and parallel factor analysis (PARAFAC) results in a powerful analytical methodology. Using TLD and PARAFAC, partially resolved components in complex mixtures can be deconvoluted and identified using only one data set without requiring either signal shape assumptions or fully selective mass signals. Specifically, a region of overlapped peaks in a complex environmental sample was mathematically resolved with TLD and PARAFAC to demonstrate the utility of these techniques as applied to GC x GC/TOFMS data of a complex mixture. For this data, it was determined that PARAFAC initiated by TLD performed a better deconvolution than TLD alone. After deconvolution, mass spectral profiles were then matched to library spectra for identification. A standard addition analysis was performed on one of the deconvoluted analytes to demonstrate the utility of TLD-initiated PARAFAC for quantification without the need for accurate retention time alignment between sample and standard data sets.

Gas Chromatography-Mass Spectrometry↗

Quantification of naphthalenes in jet fuel with GC x GC/Tri-PLS and windowed rank minimization retention time alignment.

Comprehensive, two-dimensional gas chromatography (GC x GC) is used in conjunction with trilinear partial least squares (Tri-PLS) to quantify the percent weight of naphthalenes (two-ring aromatic compounds) in jet fuel samples. The increased peak capacity and selectivity of GC x GC makes the technique attractive for the rapid, and possibly less tedious analysis of jet fuel. The analysis of complex mixtures by GC x GC is further enhanced through the use of chemometric techniques, including those designed for use on 2-D data such as Tri-PLS. Unfortunately, retention time variation, unless corrected, can be an impediment to chemometric analysis. Previous work has demonstrated that the effects of retention time variation can be mitigated in sub-regions of GC x GC chromatograms through the application of an objective retention time alignment algorithm based on rank minimization. Building upon this previous work, it is demonstrated here that the effects of retention time variation can be mitigated throughout an entire GC x GC chromatogram with an objective retention time alignment algorithm based on windowed rank minimization alignment. A significant decrease in calibration error is observed when the algorithm is applied to chromatograms prior to construction of Tri-PLS models. Fourteen jet fuel samples with known weight percentages of naphthalenes (ASTM D1840) were obtained. Each sample was subjected to five replicate five-minute GC x GC separations over a period of two days. A subset of nine samples spanning the range of weight percentages of naphthalenes was chosen as a calibration set and Tri-PLS calibration models were subsequently developed in order to predict the naphthalene content of the samples from the GC x GC chromatograms of the remaining five samples. Calibration models constructed from GC x GC chromatograms that were retention time corrected are shown to exhibit a root mean square error of prediction of roughly half that of calibration models constructed from uncorrected chromatograms. The error of prediction is lowered further to a value that nearly matches the uncertainty in the standard percent weight values (ca. 1% of the median percent volume value) when the aligned chromatograms are truncated to include only regions of the chromatogram populated by naphthalenes and compounds of similar polarity and boiling point.

Journal Article↗

Valve-based comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection: instrumentation and figures-of-merit.

A valve-based comprehensive two-dimensional gas chromatograph coupled to a time-of-flight mass spectrometer (GC x GC/TOFMS) is demonstrated. The performance characteristics of the instrument were evaluated using a complex sample containing a mixture of fuel components, natural products, and organo-phosphorous compounds. The valve-based GC x GC, designed to function with an extended temperature of operation range, is shown to have high chromatographic resolution, high separation efficiency and low detection limits. Typical peak widths at base are nominally from 100 to 300 ms on column 2 and nominally 10 s on column 1. The injected mass and injected concentration limit of detection (LOD), defined as 3 standard deviations above the mean baseline noise, for three organo-phosphorous compounds (triethylphosphorothioate (TEPT), dimethyl methyl phosphonate (DMMP) and dimethyl phosphite (DMP)) in a complex environmental sample were from 6 to 38 pg, and 3 to 17 ng/ml, respectively. The temperature program for the environmental sample ranged from 40 to 230 degrees C, a temperature range capable of analyzing semi-volatile compounds. A new compact, stand-alone, valve-pulse generator device has been implemented and is also reported. The valve-based GC x GC instrument, therefore, offers a simple, rugged and less expensive alternative to thermally modulated instruments.

Gas Chromatography-Mass Spectrometry↗

Comprehensive two-dimensional gas chromatography of volatile and semi-volatile components using a diaphragm valve-based instrument.

A high-temperature configuration for a diaphragm valve-based gas chromatography (GCXGC) instrument is demonstrated. GCxGC is a powerful instrumental tool often used to analyze complex mixtures. Previously, the temperature limitations of valve-based GCxGC instruments were set by the maximum operating temperature of the valve, typically 175 degrees C. Thus, valve-based GCxGC was constrained to the analysis of mainly volatile components; however, many complex mixtures contain semi-volatile components as well. A new configuration is described that extends the working temperature range of diaphragm valve-based GCxGC instruments to significantly higher temperatures, so both volatile and semi-volatile compounds can be readily separated. In the current investigation, separations at temperatures up to 250 degrees C are demonstrated. This new design features both chromatographic columns in the same oven with the valve interfacing the two columns mounted in the side of the oven wall so the valve is both partially inside as well as outside the oven. The diaphragm and the sample ports in the valve are located inside the oven while the temperature-restrictive portion of the valve (containing the O-rings) is outside the oven. Temperature measurements on the surface of the valve indicate that even after a sustained oven temperature of 240 degrees C, the portions of the valve directly involved with the sampling from the first column to the second column track the oven temperature to within 1.2% while the portions of the valve that are temperature-restrictive remain well below the maximum temperature of 175 degrees C. A 26-component mixture of alkanes, ketones, and alcohols whose boiling points range from 65 degrees C (n-hexane) to 270 degrees C (n-pentadecane) is used to test the new design. Peak shapes along the first column axis suggest that sample condensation or carry-over in the valve is not a problem. Chemometric data analysis is performed to demonstrate that the resulting data have a bilinear structure. After over 6 months of use and temperature conditions up to 265 degrees C, no deterioration of the valve or its performance has been observed.

Chromatography, Gas↗