Alpha4beta1 integrin affinity changes govern cell adhesion.

Integrin alpha4beta1 is a receptor for vascular cell adhesion molecule-1 and fibronectin. It is important in lymphopoiesis, inflammatory recruitment of leukocytes, and other situations that require cell adhesion to the vascular endothelium. The avidity of the cells expressing alpha4beta1 integrin can be rapidly changed by chemokines and chemoattractants. Different mechanisms, including changes in the number of interacting molecules due to the alteration of the receptor topology or changes in the affinity of the individual bonds, have been proposed to explain the nature of these fast changes in avidity. Recently, we described a fluorescent LDV-containing small molecule, which we used to monitor the affinity changes on live cells in real time (Chigaev, A., Blenc, A. M., Braaten, J. V., Kumaraswamy, N., Kepley, C. L., Andrews, R. P., Oliver, J. M., Edwards, B. S., Prossnitz, E. R., Larson, R. S. et al. (2001) J. Biol. Chem. 276, 48670-48678). Here we show that the affinity of the small molecule probe as well as the native ligand vascular cell adhesion molecule-1 varies in parallel when the integrin is modulated with divalent cations and that the affinity modulation leads to the changes in cell avidity. Using formyl peptide receptor-transfected U937 cells, we further show that the time course of avidity changes in response to the receptor activation coincides with the time course of the affinity changes. Taken together, these data are consistent with the idea that affinity regulation is a major factor that governs the avidity of cell adhesion mediated by the alpha4 integrin.

Animals↗

High-throughput flow cytometry: validation in microvolume bioassays.

BACKGROUND: We recently reported an automated sample handling system, designated HyperCyt, by which samples are aspirated from microplate wells and delivered to the flow cytometer for analysis at rates approaching 100 samples per minute. In this approach, an autosampler and peristaltic pump introduce samples into a tubing line that directly connects to the flow cytometer. Air bubbles are inserted between samples to prevent sample dispersion. In the present work, we compare results of HyperCyt with those of conventional manual flow cytometric analysis in representative flow cytometric bioassays and describe a cell suspension method in which HyperCyt exploits the use of microvolume wells. METHODS: Human eosinophils and neutrophils were treated with trypsin to generate a wide (>25-fold) range of membrane P-selectin glycoprotein ligand-1 (PSGL-1) expression and then stained with fluorescent anti-PSGL-1 antibodies. Human peripheral blood mononuclear cells were stained with fluorescein isothiocyanate- and phycoerythrin-conjugated monoclonal antibodies for multiparameter immunophenotype analysis. U937 cells labeled with PKH62GL were used to assess cell settling in microplate wells. RESULTS: Differences in PSGL-1 expression levels were detected by HyperCyt autosampling of leukocytes from 96-well plates at an analysis rate of approximately 1.5 s/well. HyperCyt measurements linearly correlated with parallel manual measurements (r(2) = 0.98). Lymphocyte subpopulations were accurately distinguished and reproducibly quantified in multiparameter immunophenotyping assays performed over a range of HyperCyt analysis rates (1.4-5.5 s/sample). When assay volumes were reduced to 10 microl/well in 60-well Terasaki plates, cells could be maintained in uniform suspension for up to 30 min by periodically inverting plates on a rotating carousel before HyperCyt analysis. HyperCyt analysis of five fluorescence-level Cyto-Plex beads sampled from Terasaki plate microwells at 2.5 s/well produced highly reproducible results over a wide range of input bead concentrations (from 7 x 10(5) to 20 x 10(6) beads/ml) that linearly correlated with manual analysis results. CONCLUSIONS: The HyperCyt autosampling system enabled a 10-fold or greater increase in sample throughput compared with conventional manual flow cytometric sample analysis, with comparable analysis results. Assays were performed efficiently in 10-microl volumes to enable significant reagent cost savings, use of quantity-limited reagents at otherwise prohibitive concentrations, and maintenance of uniform suspensions of cells for prolonged periods.

Biological Assay↗

Flow cytometric analysis of ligand-receptor interactions and molecular assemblies.

Flow cytometers make homogeneous real-time measurements of ligand-receptor interactions and, simultaneously, the physiological responses of cells. Their multiparameter capabilities are also useful in resolving multicomponent assemblies or in developing multiplexed assays. Recent advances suggest that these approaches can be extended in several important ways. Sample delivery in the millisecond time domain is applicable to the analysis of complex binding kinetics and reaction mechanisms. The homogeneous discrimination of free components and particle-based assemblies can be extended into the micromolar concentration range. Measurements can be made of molecular assemblies among proteins, DNA, RNA, lipids, and carbohydrates on beads. The topography and assembly of components within cells can be evaluated with resonance energy transfer. Temperature dependence can be evaluated with Peltier temperature control. Many assembly endpoints can be assessed through new tools for high-throughput flow cytometry using plate-based assay formats and small volume samples.

Animals↗