Search PubMed⌕ Search

Biomedical subjects

Bruce H Smaill

Publications and source records attributed to Bruce H Smaill.

11 recordsLinked to original sources

Cardiac electrophysiology and tissue structure: bridging the scale gap with a joint measurement and modelling paradigm.

Significant tissue structures exist in cardiac ventricular tissue that are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhymogenesis and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modelling. Our models have enabled us to consider key hypotheses regarding discontinuous activation. We also consider the future developments of our intact tissue experimental programme.

Action Potentials↗

Do intramural virtual electrodes facilitate successful defibrillation? Model-based analysis of experimental evidence.

INTRODUCTION: Recent computer model and experimental studies have suggested that microscopic intramural collagenous planes may facilitate successful defibrillation through the generation of shock-induced virtual electrodes deep within the ventricular wall. Evidence supporting the existence of intramural virtual electrodes has been drawn from several recent studies, which map shock-induced membrane potential (Vm) over the cut transmural surface of dissected segments of porcine left ventricle (LV). The artificially created transmural boundary in these experiments is impermeable to intracellular current. It is not known how this constraint limits the interpretation of these experiments in terms of the shock response of the intact ventricle. METHODS AND RESULTS: This study uses a realistic 3D computer model of LV myocardium to aid experimental interpretation. The model incorporates a microstructural description of intramural cleavage plane discontinuities measured by confocal microscopy of rat LV. Electrical shocks are applied across the model tissue, with and without introduced transmural boundaries. Shocks of varying strength (4-40 V/cm) are also applied to the model and the response analyzed. Results show that shock-induced Vm changes (deltaVm) on a transmural tissue boundary are significantly different to deltaVm of the intact ventricle, and the extent of difference depends on boundary orientation. However, the presence and qualitative behavior of intramural virtual electrodes is preserved irrespective of boundary placement. The model also confirms experimental observations that most rapid transmural activation occurs for shocks of strength 5-10 V/cm. Two distinct mechanisms suppress virtual electrode propagation, and hence slow tissue activation, outside of this optimal shock strength range. CONCLUSIONS: This study supports the hypothesis that distributed microscopic intramural virtual electrodes contribute to rapid activation of the ventricular wall during defibrillation.

Animals↗

Modeling cardiac electrical activity at the cell and tissue levels.

Significant tissue structures exist in cardiac ventricular tissue, which are of supracellular dimension. It is hypothesized that these tissue structures contribute to the discontinuous spread of electrical activation, may contribute to arrhythmogenesis, and also provide a substrate for effective cardioversion. However, the influences of these mesoscale tissue structures in intact ventricular tissue are difficult to understand solely on the basis of experimental measurement. Current measurement technology is able to record at both the macroscale tissue level and the microscale cellular or subcellular level, but to date it has not been possible to obtain large volume, direct measurements at the mesoscales. To bridge this scale gap in experimental measurements, we use tissue-specific structure and mathematical modeling. Our models, which can incorporate ion channel models at the cell level into the reaction-diffusion equations at the tissue level, have enabled us to consider key hypotheses regarding discontinuous activation.

Heart↗

A generalized finite difference method for modeling cardiac electrical activation on arbitrary, irregular computational meshes.

A generalized finite difference (GFD) method is presented that can be used to solve the bi-domain equations modeling cardiac electrical activity. Classical finite difference methods have been applied by many researchers to the bi-domain equations. However, these methods suffer from the limitation of requiring computational meshes that are structured and orthogonal. Finite element or finite volume methods enable the bi-domain equations to be solved on unstructured meshes, although implementations of such methods do not always cater for meshes with varying element topology. The GFD method solves the bi-domain equations on arbitrary and irregular computational meshes without any need to specify element basis functions. The method is useful as it can be easily applied to activation problems using existing meshes that have originally been created for use by finite element or finite difference methods. In addition, the GFD method employs an innovative approach to enforcing nodal and non-nodal boundary conditions. The GFD method performs effectively for a range of two and three-dimensional test problems and when computing bi-domain electrical activation moving through a fully anisotropic three-dimensional model of canine ventricles.

Algorithms↗

Automated imaging of extended tissue volumes using confocal microscopy.

Confocal microscopy enables constitutive elements of cells and tissues to be viewed at high resolution and reconstructed in three dimensions, but is constrained by the limited extent of the volumes that can be imaged. We have developed an automated technique that enables serial confocal images to be acquired over large tissue areas and volumes. The computer-controlled system, which integrates a confocal microscope and an ultramill using a high-precision translation stage, inherently preserves specimen registration, and the user control interface enables flexible specification of imaging protocols over a wide range of scales and resolutions. With this system it is possible to reconstruct specified morphological features in three dimensions and locate them accurately throughout a tissue sample. We have successfully imaged various samples at 1-mum voxel resolution on volumes up to 4 mm3 and on areas up to 75 mm2. Used in conjunction with appropriate embedding media and immuno-histochemical probes, the techniques described in this paper make it possible to routinely map the distributions of key intracellular structures over much larger tissue domains than has been easily achievable in the past.

Animals↗

Intramural measurement of transmembrane potential in the isolated pig heart: validation of a novel technique.

INTRODUCTION: Transmembrane potentials can be recorded at multiple intramural sites in the intact heart using fiber optic probes or optrodes. The technique has considerable potential utility for studies of arrhythmia and defibrillation, but has not been validated in large mammalian hearts. METHODS AND RESULTS: An optrode was used to acquire intramural transmembrane potentials in six isolated Langendorff-perfused pig hearts. Mechanical activity was suppressed with 2,3-butanedione monoxime (BDM). Excitation light (488 nm) was delivered to and fluorescence collected from six sites, each spaced 1.4 mm apart across the left ventricle (LV) free wall that was stained with di-4 ANEPPS. Intramural membrane potentials were compared with extracellular potentials recorded at adjacent locations in sinus rhythm, and during atrial and subepicardial ventricular pacing (1-3 Hz). In three hearts, epicardial intracellular potentials were also measured close to the optrode. Optical action potentials were reproducible, with no significant transmural variation in morphology. There was close correspondence between subepicardial optical and intracellular potentials (R2 = 0.948, n = 23). The onset of activation at and its progression across adjacent optical and extracellular recording sites were consistent, as was the variation of action potential duration (APD) with cycle length. However, there was greater variability in absolute APD estimated from optical and extracellular records (R2 = 0.773, n = 258). Comparison of extracellular potentials at the same intramural sites in vivo confirms that heart isolation and BDM slow electrical propagation and depress restitution relationships, but otherwise preserve intramural patterns of electrical activation. CONCLUSIONS: We have demonstrated that our optrode provides reliable intramural transmembrane potential recordings in the isolated pig heart preparation.

Action Potentials↗

Correction of motion artifact in transmembrane voltage-sensitive fluorescent dye emission in hearts.

Fast voltage-sensitive dyes are widely used to image cardiac electrical activity. Typically, the emission spectrum of these fluorochromes is wavelength shifted with altered membrane potential, but the optical signals obtained also decay with time and are affected by contraction. Ratiometry reduces, but may not fully remove, these artifacts. An alternate approach has been developed in which the time decay in simultaneously acquired short- and long-wavelength signals is characterized nonparametrically and removed. Motion artifact is then identified as the time-varying signal component common to both decay-corrected signals and subtracted. Performance of this subtraction technique was compared with ratiometry for intramural optical signals acquired with a fiber-optic probe in an isolated, Langendorff-perfused pig heart preparation (n = 4) stained with di-4-ANEPPS. Perfusate concentration of 2,3-butanedione monoxime was adjusted (7.5-12.5 mM) to alter contractile activity. Short-wavelength (520-600 nm) and long-wavelength (>600 nm) signals were recorded over 8-16 cardiac cycles at 6 sites across the left ventricular free wall in sinus rhythm and during pacing. A total of 451 such data sets were acquired. Appreciable wall motion was observed in 225 cases, with motion artifact classed as moderate (less than modulation due to action potential) in 187 and substantial (more than modulation due to action potential) in 38. In all cases, subtraction performed as well as, or better than, ratiometry in removing motion artifact and decay. Action potential morphology was recovered more faithfully by subtraction than by ratiometry in 58 of 187 and 31 of 38 cases with moderate and substantial motion artifact, respectively. This novel subtraction approach may therefore provide a means of reducing the concentration of uncoupling agents used in cardiac optical mapping studies.

Action Potentials↗

Cardiac structure and electrical activation: models and measurement.

1. Our group has developed finite element models of ventricular anatomy that incorporate detailed structural information. These have been used to study normal electrical activation and re-entrant arrhythmia. 2. A model based on the actual three-dimensional microstructure of a transmural left ventricular (LV) segment predicts that cleavage planes between muscle layers may give rise to non-uniform, anisotropic electrical propagation and also provide a substrate for bulk resetting of the myocardium during defibrillation. 3. The model predictions are consistent with the results of preliminary experiments in which a novel fibre-optic probe is used to record transmembrane potentials at multiple intramural sites in the intact heart. Extracellular potentials are recorded at adjacent LV sites in these studies. 4. We conclude that structural discontinuities in ventricular myocardium may play a role in the initiation of re-entrant arrhythmia and discuss future studies that address this hypothesis.

Animals↗

Modeling total heart function.

Computational models of the electrical and mechanical function of the heart are reviewed. These models attempt to explain the integrated function of the heart in terms of ventricular anatomy, the structure and material properties of myocardial tissue, the membrane ion channels, and calcium handling and myofilament mechanics of cardiac myocytes. The models have established the computational framework for linking the structure and function of cardiac cells and tissue to the integrated behavior of the intact heart, but many more aspects of physiological function, including metabolic and signal transduction pathways, need to be included before significant progress can be made in understanding many disease processes.

Animals↗

Cardiac microstructure: implications for electrical propagation and defibrillation in the heart.

Our understanding of the electrophysiological properties of the heart is incomplete. We have investigated two issues that are fundamental to advancing that understanding. First, there has been widespread debate over the mechanisms by which an externally applied shock can influence a sufficient volume of heart tissue to terminate cardiac fibrillation. Second, it has been uncertain whether cardiac tissue should be viewed as an electrically orthotropic structure, or whether its electrical properties are, in fact, isotropic in the plane orthogonal to myofiber direction. In the present study, a computer model that incorporates a detailed three-dimensional representation of cardiac muscular architecture is used to investigate these issues. We describe a bidomain model of electrical propagation solved in a discontinuous domain that accurately represents the microstructure of a transmural block of rat left ventricle. From analysis of the model results, we conclude that (1) the laminar organization of myocytes determines unique electrical properties in three microstructurally defined directions at any point in the ventricular wall of the heart, and (2) interlaminar clefts between layers of cardiomyocytes provide a substrate for bulk activation of the ventricles during defibrillation.

Animals↗

Shear properties of passive ventricular myocardium.

We examined the shear properties of passive ventricular myocardium in six pig hearts. Samples (3 x 3 x 3 mm) were cut from adjacent regions of the lateral left ventricular midwall, with sides aligned with the principal material axes. Four cycles of sinusoidal simple shear (maximum shear displacements of 0.1-0.5) were applied separately to each specimen in two orthogonal directions. Resulting forces along the three axes were measured. Three specimens from each heart were tested in different orientations to cover all six modes of simple shear deformation. Passive myocardium has nonlinear viscoelastic shear properties with reproducible, directionally dependent softening as strain is increased. Shear properties were clearly anisotropic with respect to the three principal material directions: passive ventricular myocardium is least resistant to simple shear displacements imposed in the plane of the myocardial layers and most resistant to shear deformations that produce extension of the myocyte axis. Comparison of results for the six different shear modes suggests that simple shear deformation is resisted by elastic elements aligned with the microstructural axes of the tissue.

Animals↗