Search PubMed⌕ Search

Biomedical subjects

Bruce A Beckwith

Publications and source records attributed to Bruce A Beckwith.

3 recordsLinked to original sources

Development and evaluation of an open source software tool for deidentification of pathology reports.

BACKGROUND: Electronic medical records, including pathology reports, are often used for research purposes. Currently, there are few programs freely available to remove identifiers while leaving the remainder of the pathology report text intact. Our goal was to produce an open source, Health Insurance Portability and Accountability Act (HIPAA) compliant, deidentification tool tailored for pathology reports. We designed a three-step process for removing potential identifiers. The first step is to look for identifiers known to be associated with the patient, such as name, medical record number, pathology accession number, etc. Next, a series of pattern matches look for predictable patterns likely to represent identifying data; such as dates, accession numbers and addresses as well as patient, institution and physician names. Finally, individual words are compared with a database of proper names and geographic locations. Pathology reports from three institutions were used to design and test the algorithms. The software was improved iteratively on training sets until it exhibited good performance. 1800 new pathology reports were then processed. Each report was reviewed manually before and after deidentification to catalog all identifiers and note those that were not removed. RESULTS: 1254 (69.7 %) of 1800 pathology reports contained identifiers in the body of the report. 3439 (98.3%) of 3499 unique identifiers in the test set were removed. Only 19 HIPAA-specified identifiers (mainly consult accession numbers and misspelled names) were missed. Of 41 non-HIPAA identifiers missed, the majority were partial institutional addresses and ages. Outside consultation case reports typically contain numerous identifiers and were the most challenging to deidentify comprehensively. There was variation in performance among reports from the three institutions, highlighting the need for site-specific customization, which is easily accomplished with our tool. CONCLUSION: We have demonstrated that it is possible to create an open-source deidentification program which performs well on free-text pathology reports.

Computer Security↗

The scratch test.

Explore the source record for details and available documents.

Artifacts↗

Artifactual hyperbilirubinemia due to paraprotein interference.

CONTEXT: Paraprotein interference in automated chemistry is uncommon. We describe 2 patients with paraproteinemia and elevated total bilirubin levels measured erroneously using the Roche total bilirubin assay. OBJECTIVES: To explain the mechanism of this artifactual hyperbilirubinemia and to determine its frequency in patients with monoclonal or increased immunoglobulins. MATERIALS AND METHODS: The assay was performed manually using serum from 2 index patients and from control patients (without M proteins). Total bilirubin was also determined using another manufacturer's assay. A prospective study was then undertaken using serum from 100 consecutive patients with various monoclonal gammopathies and from 13 patients with polyclonal hypergammaglobulinemia and cryoglobulins. For all patients, serum immunoglobulin (Ig) G, IgA, IgM, total and direct bilirubin, creatinine, and a direct spectrophotometric assessment of icterus were measured. RESULTS: After the addition of assay reagents, a white precipitate formed in the reaction mixtures containing serum from the index patients, but not in other samples. This turbidity, rather than the expected color change to pink, increased the absorbance and falsely elevated the total bilirubin value. Serum from both index patients was anicteric, their direct bilirubin measurements were unaffected, and total bilirubin measured using an alternate assay was normal. Among the 113 patients studied, no additional spurious total bilirubin values were detected. CONCLUSION: Paraprotein interference with the Roche automated total bilirubin assay is caused by precipitate formation. This interference is rare and probably idiosyncratic. Spurious hyperbilirubinemia from paraprotein interference may cause clinical confusion. If artifactual elevation of total bilirubin is suspected, the laboratory should examine the specimen for icterus (manually or by spectrophotometry) or measure total bilirubin using a different method.

Aged↗