Direct MR venography of persistent sciatic vein in a patient with Klippel-Trenaunay-Weber syndrome.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Brian Funaki.
Explore the source record for details and available documents.
OBJECTIVE: We used pullback pressure measurements to identify venous stenoses persisting after angioplasty of failing hemodialysis grafts. MATERIALS AND METHODS: Fifty angioplasty procedures were performed in 32 patients with elevated venous pressures at dialysis. Grafts were initially evaluated on digital subtraction angiography, and all stenoses measuring greater than 50% on angiography underwent angioplasty. In successful cases (residual stenosis < 30%), pullback pressure measurements were obtained from the superior vena cava to the graft to identify hemodynamically significant (> 10 mm Hg) stenoses. These lesions were then treated with repeated angioplasty. RESULTS: Hemodynamically significant stenoses with a gradient range of 10-27 mm Hg (mean, 16 mm Hg) were found in nine (18%) of 50 procedures. All gradients occurred at sites of previous angioplasty. Repeated angioplasty of these stenoses performed with larger angioplasty balloons reduced gradients to less than 3 mm Hg in six stenoses and to 5 mm Hg in three stenoses. In this subgroup, primary patency was eight (89%) of nine stenoses at 1 month and 2 months and five (56%) of nine stenoses at 6 months. Using life table analysis, we found that primary patency of the entire population was 84% at 1 month, 66% at 2 months, and 47% at 6 months. The mean time between interventions was 6 months, and the thrombosis rate was 0.32 per year. CONCLUSION: Pullback pressure measurements are a useful adjunct to angiography to evaluate the hemodynamic results of angioplasty in patients with failing hemodialysis grafts.
Explore the source record for details and available documents.
We compared single- and double-stick techniques of percutaneous nephrostomy insertion by retrospectively reviewing 140 percutaneous nephrostomy procedures in 101 patients. All procedures were performed by residents or fellows with direct attending supervision. Either the single-stick or double-stick technique was used based solely on personal attending preference. There were no significant differences in groups in terms of age, sex, or degree of hydronephrosis. In the single-stick technique, the kidney was punctured with sonographic guidance and the tract was serially dilated to accept an 8.5 Fr. nephrostomy catheter. In the double-stick technique, the kidney was punctured with sonographic guidance and a mixture of air and contrast were injected into the collecting system. The affected side was then elevated and a posterior calyx was punctured using fluoroscopic guidance. Both groups were compared in terms of complications and early tube dysfunction using the chi-squared test. All procedures were successful without immediate complications. Bleeding requiring transfusion occurred in 4.7% (4/86) procedures in the single stick group and 3.7% (2/54) in the double stick group (p-value not significant). None of these patients required further interventions for bleeding. Tube dysfunction leading to premature tube exchange occurred in 3.5% (3/86) of catheters in the single stick group and 3.7% (2/54) of catheters in the double-stick group (p-value not significant). We found no significant difference between the single and double-stick methods of percutaneous nephrostomy in terms of success rates, complications, or tube function. We believe that the single-stick method should be adopted as the insertion technique of choice.
PURPOSE: To determine the safety and efficacy of transjugular intrahepatic portosystemic shunt (TIPS) creation in patients with liver cirrhosis complicated by thrombosed portal vein. METHODS: This study reviewed 15 cases of TIPS creation in 15 cirrhotic patients with portal vein thrombosis at our institution over an 8-year period. There were 2 women and 13 men with a mean age of 53 years. Indications were refractory ascites, variceal hemorrhage, and refractory pleural effusion. Clinical follow-up was performed in all patients. RESULTS: The technical success rate was 75% (3/4) in patients with chronic portal vein thrombosis associated with cavernomatous transformation and 91% (10/11) in patients with acute thrombosis or partial thrombosis, giving an overall success rate of 87%. Complications included postprocedural encephalopathy and localized hematoma at the access site. In patients with successful shunt placement, the total follow-up time was 223 months. The 30-day mortality rate was 13%. Two patients underwent liver transplantation at 35 days and 7 months, respectively, after TIPS insertion. One patient had an occluded shunt at 4 months with an unsuccessful revision. The remaining patients had functioning shunts at follow-up. CONCLUSION: TIPS creation in thrombosed portal vein is possible and might be a treatment option in certain patients.
Venous stenoses are the leading cause of dialysis graft and mature dialysis fistula malfunction. We report a simple, inexpensive technique for treating stenoses that are refractory to conventional balloon angioplasty and present a case in which this technique was successfully applied.