Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from off-resonance effects such as field or susceptibility variations. A new method, dual-acquisition phase-sensitive SSFP, combines the signals from two standard balanced SSFP acquisitions to separate fat and water while simultaneously reducing the signal voids. The acquisitions are added in quadrature and then phase corrected using a simple algorithm before fat and water can be identified simply by the sign of the signal. This method is especially useful for applications at high field, where the RF power deposition, spatial resolution requirements and gradient strength limit the minimum repetition times. Finally, dual-acquisition phase-sensitive SSFP can be combined with other magnetization preparation schemes to produce specific image contrast in addition to separating fat and water signals.

Adipose Tissue↗

Fluid-attenuated inversion-recovery SSFP imaging.

PURPOSE: To describe and evaluate a fast, fluid-suppressed 2D multislice steady-state free precession (SSFP) neuroimaging sequence. MATERIALS AND METHODS: We developed a fast fluid-attenuated inversion-recovery SSFP sequence for use in neuroimaging. The inversion time (TI) was optimized to yield good cerebrospinal fluid (CSF) suppression while conserving white matter (WM)/lesion contrast across a broad range of flip angles. Multiple SSFP acquisitions were combined using the sum-of-squares (SOS) method to maximize SNR efficiency while minimizing SSFP banding artifacts. We compared our fluid-attenuated inversion-recovery (FLAIR) SSFP sequence with FLAIR fast spin-echo (FSE) in both normal subjects and a volunteer with multiple sclerosis. SNR measurements were performed to ascertain the SNR efficiency of each sequence. RESULTS: Our FLAIR SSFP sequence demonstrated excellent CSF suppression and good gray matter (GM)/WM contrast. Coverage of the entire brain (5-mm slices, 24-cm FOV, 256 x 192 matrix) was achieved with FLAIR SSFP in less than half the scan time of a corresponding FLAIR FSE sequence with similar SNR, yielding improvements of more than 50% in SNR efficiency. Axial scans of a volunteer with multiple sclerosis show clearly visible plaques and very good visualization of brain parenchyma. CONCLUSION: We have demonstrated the feasibility of a very fast fluid-suppressed neuroimaging technique using SSFP.

Algorithms↗

Single breath-hold whole-heart MRA using variable-density spirals at 3T.

Multislice breath-held coronary imaging techniques conventionally lack the coverage of free-breathing 3D acquisitions but use a considerably shorter acquisition window during the cardiac cycle. This produces images with significantly less motion artifact but a lower signal-to-noise ratio (SNR). By using the extra SNR available at 3 T and undersampling k-space without introducing significant aliasing artifacts, we were able to acquire high-resolution fat-suppressed images of the whole heart in 17 heartbeats (a single breath-hold). The basic pulse sequence consists of a spectral-spatial excitation followed by a variable-density spiral readout. This is combined with real-time localization and a real-time prospective shim correction. Images are reconstructed with the use of gridding, and advanced techniques are used to reduce aliasing artifacts.

Artifacts↗

Design and analysis of a practical 3D cones trajectory.

The 3D Cones k-space trajectory has many desirable properties for rapid and ultra-short echo time magnetic resonance imaging. An algorithm is presented that generates the 3D Cones gradient waveforms given a desired field of view and resolution. The algorithm enables a favorable trade-off between increases in readout time and decreases in the total number of required readouts. The resulting trajectory is very signal-to-noise ratio (SNR) efficient and has excellent aliasing properties. A rapid high-resolution ultra-short echo time imaging sequence is used to compare the 3D Cones trajectory to 3D projection reconstruction (3DPR) sampling schemes. For equivalent scan times, the 3D Cones trajectory has better SNR performance and fewer aliasing artifacts as compared to the 3DPR trajectory.

Algorithms↗

Respiration-induced B0 field fluctuation compensation in balanced SSFP: real-time approach for transition-band SSFP fMRI.

In functional MRI (fMRI) the resonance frequency shift induced from respiration is a major source of physiological noise. In transition-band SSFP fMRI the respiration-induced resonance offset not only increases noise interference, it also shifts the activation band. This leads to a reduction in the contrast-to-noise ratio (CNR) and the potential for varying contrast levels during the experiment. A novel real-time method that compensates for the respiration-induced resonance offset frequency is presented. This method utilizes free induction decay (FID) phase information to measure the resonance offset. For compensation, one can update the resonant frequency in real time by changing the transmit RF pulse and receiver phases to track the measured offset. The results show decreased signal power in the respiration frequency band and increased numbers of activated voxels with higher Z-scores compared to uncompensated experiments.

Algorithms↗

Advanced magnetic resonance imaging of articular cartilage.

MRI is one of the most accurate imaging methods available to diagnose disorders of articular cartilage. Conventional two-dimensional and three-dimensional approaches show changes in cartilage morphology. Newer and substantially faster three-dimensional imaging methods show great promise to improve MRI of cartilage. These methods may allow acquisition of fluid-sensitive isotropic data that can be reformatted into arbitrary planes for improved detection and visualization of pathology. Unique MRI contrast mechanisms also allow clinicians to probe cartilage physiology and detect early changes in cartilage macromolecules.

Cartilage, Articular↗

Articular cartilage of the knee: evaluation with fluctuating equilibrium MR imaging--initial experience in healthy volunteers.

Institutional review board approval and informed consent were obtained for this HIPAA-compliant study, whose purpose was to prospectively compare three magnetic resonance (MR) imaging techniques-fluctuating equilibrium, three-dimensional (3D) spoiled gradient-recalled acquisition in the steady state (SPGR), and two-dimensional (2D) fast spin echo (SE)-for evaluating articular cartilage in the knee. The study cohort consisted of 10 healthy volunteers (four men, six women; age range, 26-42 years). Cartilage signal-to-noise ratio (SNR), SNR efficiency, cartilage-fluid contrast-to-noise ratio (CNR), CNR efficiency, image quality, cartilage visibility, and fat suppression were compared. Cartilage volume was compared for the fluctuating equilibrium and 3D SPGR techniques. Compared with 3D SPGR and 2D fast SE, fluctuating equilibrium yielded the highest cartilage SNR efficiency and cartilage-fluid CNR efficiency (P < .01 for both). Image quality was similar with all sequences. Fluctuating equilibrium imaging yielded higher cartilage visibility than did 2D fast SE imaging (P <. 01) but worse fat suppression than did 3D SPGR and 2D fast SE imaging (P < .04). Cartilage volume measurements with fluctuating equilibrium and 3D SPGR were similar. Fluctuating equilibrium MR imaging is a promising method for evaluating articular cartilage in the knee.

Adult↗

Driven equilibrium magnetic resonance imaging of articular cartilage: initial clinical experience.

PURPOSE: To evaluate three-dimensional driven equilibrium Fourier transform (3D-DEFT) for image quality and detection of articular cartilage lesions in the knee. MATERIALS AND METHODS: We imaged 104 consecutive patients with knee pain with 3D-DEFT and proton density (PD-FSE) and T2-weighted (T2-FSE) fast spin echo. Twenty-four went on to arthroscopy. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) efficiency were measured. Subjective image quality, fat suppression, and cartilage thickness visibility were assessed. Cartilage lesions on 3D-DEFT and T2-FSE were compared with findings outlined in operative reports. RESULTS: SNR efficiency was higher for 3D-DEFT and PD-FSE than for T2-FSE (P < 0.02). 3D-DEFT and PD-FSE showed superior cartilage thickness visibility compared with T2-FSE (P < 0.02). T2-FSE showed better fat suppression and fewer image artifacts than 3D-DEFT (P < 0.04). 3D-DEFT had similar sensitivity and similar specificity for cartilage lesions compared with PD-FSE and T2-FSE. CONCLUSION: 3D-DEFT provides excellent synovial fluid-to-cartilage contrast while preserving signal from cartilage, giving this method a high cartilage SNR. 3D-DEFT shows the full cartilage thickness better than T2-FSE. T2-FSE had superior fat saturation and fewer artifacts than 3D-DEFT. Overall, 3D-DEFT requires further technical development, but is a promising method for imaging articular cartilage.

Arthroscopy↗

Rapid measurement of renal artery blood flow with ungated spiral phase-contrast MRI.

PURPOSE: To verify the potential of ungated spiral phase-contrast (USPC), which has been shown to provide accurate and reproducible time-averaged measurements of pulsatile flow, for rapid measurement of renal artery blood flow (RABF) in vivo. MATERIALS AND METHODS: The RABF rates of 11 normal human subjects and one patient with renal failure were measured with USPC within six seconds. RESULTS: Rapid USPC scans produced reproducible RABF measurements (SD < or = 9%) that agreed with the normal RABF rates known from the literature. The RABF rates of the patient with renal failure were substantially less (<50-65%) than the normal RABF rates. CONCLUSION: The results demonstrate that it is now possible to obtain rapid and consistent RABF measurements within six seconds with USPC.

Adult↗

Spiral balanced steady-state free precession cardiac imaging.

Balanced steady-state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood-myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced SSFP has been combined with spiral imaging for real-time interactive cardiac MRI. New features of this method to enable scanning in a clinical setting include short, first-moment nulled spiral trajectories and interactive control over the spatial location of banding artifacts (SSFP-specific signal variations). The feasibility of spiral balanced SSFP cardiac imaging at 1.5 T is demonstrated. In observations from over 40 volunteer and patient studies, spiral balanced SSFP imaging shows significantly improved contrast compared to spiral gradient-spoiled imaging, producing better visualization of cardiac function, improved localization, and reduced flow artifacts from blood.

Artifacts↗

Homodyne reconstruction and IDEAL water-fat decomposition.

Multipoint water-fat separation methods have received renewed interest because they provide uniform separation of water and fat despite the presence of B0 and B1 field inhomogeneities. Unfortunately, full-resolution reconstruction of partial k-space acquisitions has been incompatible with these methods. Conventional homodyne reconstruction and related algorithms are commonly used to reconstruct partial k-space data sets by exploiting the Hermitian symmetry of k-space in order to maximize the spatial resolution of the image. In doing so, however, all phase information of the image is lost. The phase information of complex source images used in a water-fat separation acquisition is necessary to decompose water from fat. In this work, homodyne imaging is combined with the IDEAL (iterative decomposition of water and fat with echo asymmetry and least squares estimation) method to reconstruct full resolution water and fat images free of blurring. This method is extended to multicoil steady-state free precession and fast spin-echo applications and examples are shown.

Adipose Tissue↗

Variable-density one-shot Fourier velocity encoding.

In areas of highly pulsatile and turbulent flow, real-time imaging with high temporal, spatial, and velocity resolution is essential. The use of 1D Fourier velocity encoding (FVE) was previously demonstrated for velocity measurement in real time, with fewer effects resulting from off-resonance. The application of variable-density sampling is proposed to improve velocity measurement without a significant increase in readout time or the addition of aliasing artifacts. Two sequence comparisons are presented to improve velocity resolution or increase the velocity field of view (FOV) to unambiguously measure velocities up to 5 m/s without aliasing. The results from a tube flow phantom, a stenosis phantom, and healthy volunteers are presented, along with a comparison of measurements using Doppler ultrasound (US). The studies confirm that variable-density acquisition of kz-kv space improves the velocity resolution and FOV of such data, with the greatest impact on the improvement of FOV to include velocities in stenotic ranges.

Aorta, Abdominal↗

Automatic tuning of flexible interventional RF receiver coils.

Microcontroller-based circuitry was built and tested for automatically tuning flexible RF receiver coils at the touch of a button. This circuitry is robust to 10% changes in probe center frequency, is in line with the scanner, and requires less than 1 s to tune a simple probe. Images were acquired using this circuitry with a varactor-tunable 1-inch flexible probe in a phantom and in an in vitro porcine knee model. The phantom experiments support the use of automatic tuning by demonstrating 30% signal-to-noise ratio (SNR) losses for 5% changes in coil center frequency, in agreement with theoretical calculations. Comparisons between patellofemoral cartilage images obtained using a 3-inch surface coil and the surgically-implanted 1-inch flexible coil reveal a worst-case local SNR advantage of a factor of 4 for the smaller coil. This work confirms that surgically implanted coils can greatly improve resolution in small-field-of-view (FOV) applications, and demonstrates the importance and feasibility of automatically tuning such probes.

Animals↗

Controversies in protocol selection in the imaging of articular cartilage.

Magnetic resonance (MR) imaging, with its unique ability to noninvasively image and characterize soft tissue, has shown promise in assessment of cartilage. The development of new, fast imaging methods with high contrast will improve the MR evaluation of cartilage morphology. In addition to morphological MR imaging methods, MR imaging contrast mechanisms under development may reveal detailed information regarding the physiology of cartilage. However, many of these methods remain to be tested in the clinical setting. Protocol selection for cartilage imaging requires understanding of the patient population and the advantages and limitations of these techniques.

Cartilage Diseases↗

Magnetic resonance imaging of articular cartilage of the knee: comparison between fat-suppressed three-dimensional SPGR imaging, fat-suppressed FSE imaging, and fat-suppressed three-dimensional DEFT imaging, and correlation with arthroscopy.

PURPOSE: To compare signal-to-noise ratios (S/N) and contrast-to-noise ratios (C/N) in various MR sequences, including fat-suppressed three-dimensional spoiled gradient-echo (SPGR) imaging, fat-suppressed fast spin echo (FSE) imaging, and fat-suppressed three-dimensional driven equilibrium Fourier transform (DEFT) imaging, and to determine the diagnostic accuracy of these imaging sequences for detecting cartilage lesions in osteoarthritic knees, as compared with arthroscopy. MATERIALS AND METHODS: Two sagittal fat-suppressed FSE images (repetition time [TR] / echo time [TE], 4000/13 [FSE short TE] and 4000/39 [FSE long TE]), sagittal fat-suppressed three-dimensional SPGR images (60/5, 40 degrees flip angle), and sagittal fat-suppressed echo-planar three-dimensional DEFT images (400/21.2) were acquired in 35 knees from 28 patients with osteoarthritis of the knee. The S/N efficiencies (S/Neffs) of cartilage, synovial fluid, muscle, meniscus, bone marrow, and fat tissue, and the C/N efficiencies (C/Neffs) of these structures were calculated. Kappa values, exact agreement, sensitivity, specificity, positive predictive value, and negative predictive value were determined by comparison of MR grading with arthroscopic results. RESULTS: The synovial fluid S/Neff on fat-suppressed FSE short TE images, fat-suppressed FSE long TE images, and fat-suppressed three-dimensional DEFT images showed similar values. Fat-suppressed three-dimensional DEFT images showed the highest fluid-cartilage C/Neff of all sequences. All images showed fair to good agreement with arthroscopy (kappa, 0.615 in FSE short TE, 0.601 in FSE long TE, 0.583 in three-dimensional SPGR, and 0.561 in three-dimensional DEFT). Although the sensitivity of all sequences was high (100% in FSE short TE, FSE long TE, and DEFT; 96.7% in SPGR), specificity was relatively low (67.6% in FSE short TE and FSE long TE; 85.3% in SPGR; 58.3% in DEFT). The peripheral area of bone marrow edema or whole area of bone marrow edema on fat-suppressed FSE images was demonstrated as low or iso-signal intensity on fat-suppressed three-dimensional DEFT images. CONCLUSION: Fat-suppressed three-dimensional SPGR imaging and fat-suppressed FSE imaging showed high sensitivity and high negative predictive values, but relatively low specificity. The Kappa value and exact agreement was the highest on fat-suppressed FSE short TE images. Fat-suppressed three-dimensional DEFT images showed results similar to the conventional sequences.

Adult↗

Time-optimal multidimensional gradient waveform design for rapid imaging.

Magnetic resonance imaging (MRI) is limited in many cases by long scan times and low spatial resolution. Recent advances in gradient systems hardware allow very rapid imaging sequences, such as steady-state free precession (SSFP), which has repetition times (TRs) of 2-5 ms. The design of these rapid sequences demands time-optimal preparatory gradient waveforms to provide maximum readout duty-cycle, and preserve spatial resolution and SNR while keeping TRs low. Time-optimal gradient waveforms can be synthesized analytically for certain simple cases. However, certain problems, such as time-optimal 2D and 3D gradient design with moment constraints, either may not have a solution or must be solved numerically. We show that time-optimal gradient design is a convex-optimization problem, for which very efficient solution methods exist. These methods can be applied to solve gradient design problems for oblique gradient design, spiral imaging, and flow-encoding using either a constant slew rate or the more exact voltage-limited gradient models. Ultimately, these methods provide a time-optimal solution to many 2D and 3D gradient design problems in a sufficiently short time for interactive imaging.

Magnetic Resonance Imaging↗

Steady-state diffusion-weighted imaging of in vivo knee cartilage.

Diffusion-weighted imaging (DWI) has strong potential as a diagnostic for early cartilage damage, with clinical impact for diseases such as osteoarthritis. However, in vivo DWI of cartilage has proven difficult with conventional methods due to the short T2. This work presents a 3D steady-state DWI sequence that is able to image short-T2 species with high SNR. When combined with 2D navigator correction of motion-induced phase artifacts, this method enables high resolution in vivo DWI of cartilage. In vivo knee images in healthy subjects are presented with high SNR (SNR = 110) and submillimeter in-plane resolution (0.5 x 0.7 x 3.0 mm(3)). A method for fitting the diffusion coefficient is presented which produces fits within 10% of literature values. This method should be applicable to other short-T2 tissues, such as muscle, which are difficult to image using traditional DWI methods.

Artifacts↗