Simulation of scattering and attenuation of 511 keV photons in a combined PET/field-cycled MRI system.

Mixing the imaging modalities of positron emission tomography (PET) and magnetic resonance imaging (MRI) will offer the best soft tissue contrast (MRI) with information about metabolic function (PET). The high magnetic field environment of an MRI system makes the detection of annihilation photons difficult, as the response of standard photo-multiplier tubes is compromised. An approach using field-cycled MRI is discussed here, as field-cycled MRI makes it possible to have long periods of time available for nuclear imaging when there is no magnetic field present. This work focuses upon the effect of the field-cycled MRI upon the nuclear image due to the added material providing additional attenuation of the PET signal, and additional nuclei for scatter. These effects are studied using a Monte Carlo simulation based upon the GEANT libraries. Attenuation effects are shown to be significant, approximately 6% for the RF shield and coil and approximately 24% for the gradients. No significant effect is seen in image quality due to the scattering of the gammas. With these levels of attenuation it is concluded that open gradient coils and shim coils are required around the imaging volume.

Computer Simulation↗

Consideration of magnetically-induced and conservative electric fields within a loaded gradient coil.

We present a method to calculate the electric (E)-fields within and surrounding a human body in a gradient coil, including E-fields induced by the changing magnetic fields and "conservative" E-fields originating with the scalar electrical potential in the coil windings. In agreement with previous numerical calculations, it is shown that magnetically-induced E-fields within the human body show no real concentration near the surface of the body, where nerve stimulation most often occurs. Both the magnetically-induced and conservative E-fields are shown to be considerably stronger just outside the human body than inside it, and under some circumstances the conservative E-fields just outside the body can be much larger than the magnetically-induced E-fields there. The order of gradient winding and the presence of conductive RF shield can greatly affect the conservative E-field distribution in these cases. Though the E-fields against the outer surface of the body are not commonly considered, understanding gradient E-fields may be important for reasons other than peripheral nerve stimulation (PNS), such as potential interaction with electrical equipment.

Computer Simulation↗

Shim design using a linear programming algorithm.

The advent of open magnetic resonance imaging (MRI) scanners and dedicated MRI scanners tailored to specific body parts has led to an increasing number of noncylindrical MRI scanner geometries, for which noncylindrical gradients and shims are needed. These new scanner geometries are driving the need for fast, flexible shim design methods that can design shim coils for any geometry. A linear programming (LP) algorithm was developed to design minimum-power resistive shim coils on an arbitrary surface. These coils can be designed to produce any order shim field over an arbitrarily shaped target region, which can be placed anywhere within the coil. The resulting designs are relatively sparse and can be readily constructed. This algorithm was used to design and construct a seven-coil cylindrical shim set for a knee imaging magnet with a cylindrical homogeneous region. The algorithm was then used to design shim coils for a biradial head imager with an asymmetrically located spherical target region for brain imaging.

Algorithms↗

Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils.

PURPOSE: To examine peripheral nerve stimulation (PNS) thresholds for normal human subjects in magnetic resonance imaging (MRI) gradient coils, and determine if observed thresholds could be predicted based on gross physiologic measurements. MATERIALS AND METHODS: PNS thresholds for 21 healthy normal subjects were measured using a whole-body gradient coil. Subjects were exposed to a trapezoidal echo-planar imaging (EPI) gradient waveform and the total change in gradient strength (DeltaG) required to cause PNS as a function of the duration of the gradient switching time (tau) were measured. Correlation coefficients and corresponding P values were calculated for the PNS threshold measurements against simple physiologic measurements taken of the subjects, including weight, height, girth, and average body fat percentage, in order to determine if there were any easily observable dependencies. RESULTS: No convincing correlations between threshold parameters and gross physiologic measurements were observed. CONCLUSION: These results suggest it is unlikely that a simple physiologic measurement of subject anatomy can be used to guide the operation of MRI scanners in a subject-specific manner in order to increase gradient system performance while avoiding PNS.

Echo-Planar Imaging↗

Peripheral nerve stimulation properties of head and body gradient coils of various sizes.

Peripheral nerve stimulation (PNS) caused by time-varying magnetic fields has been studied both theoretically and experimentally. A human volunteer study performed on three different body-size gradient coils and one head-size gradient coil is presented in this work. The experimental results were used to generate average PNS threshold parameters for the tested gradient systems. It was found that the average stimulation threshold increases while gradient-region-of-uniformity size decreases. In addition, linear relationships between PNS parameters and diameter of homogeneous gradient spherical volume (DSV) were discovered: SR(min) and DeltaG(min) both vary inverse linearly with DSV. More importantly, the chronaxie value was found to vary inversely linearly with the DSV. This finding indicates that, contrary to the general understanding, the parameter "chronaxie" in the commonly accepted simple stimulation models cannot be considered to be a single-value, nerve-specific constant. A modified linear model for gradient-induced PNS based on these results was developed, which may permit, for the first time, the general prediction of nerve stimulation properties for gradient coils of arbitrary linear region dimension.

Adolescent↗