Search PubMed⌕ Search

Biomedical subjects

Bettina Sorger

Publications and source records attributed to Bettina Sorger.

6 recordsLinked to original sources

Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: removal of the ballistocardiogram artefact.

EEG signals recorded simultaneously with fMRI are massively compromised by severe artefacts, among them the cardiac cycle-related ballistocardiogram (BCG) artefact. Different methods have been proposed to remove the BCG artefact focusing on channel-wise template subtraction procedures or spatial filtering approaches such as independent component analysis (ICA). Here we systematically compared the performance of the optimal basis set (OBS), a channel-wise correction approach, with ICA and a recently proposed combination of both (OBS-ICA). The three different procedures were applied to 60-channel EEG data from 12 subjects recorded during fMRI acquisition in a 3-T scanner. In addition to examination of the residual BCG artefact, the signal-to-noise ratio (SNR) and the topography of the resulting auditory evoked potential component N1 were compared. Whereas all three approaches led to a significant artefact reduction, the ICA procedure resulted in a significantly reduced N1 SNR and amplitude when compared to BCG-uncorrected data, indicating a rather poor performance. In contrast to ICA, OBS and OBS-ICA corrected data substantially improved the SNR of the N1. The quality of the auditory evoked potential N1 topography was investigated by means of equivalent current dipole modelling. On a descriptive level, all three correction procedures led to a reduced localization error when compared to BCG-uncorrected data. This improvement was significant for OBS-ICA. We conclude that OBS and OBS-ICA can efficiently remove BCG artefacts and substantially improve the quality of EEG signals recorded inside the scanner, a prerequisite for the successful integration of simultaneously recorded EEG and fMRI.

Adult↗

Impaired face discrimination in acquired prosopagnosia is associated with abnormal response to individual faces in the right middle fusiform gyrus.

The middle fusiform gyrus (MFG) and the inferior occipital gyrus (IOG) are activated by both detection and identification of faces. Paradoxically, patients with acquired prosopagnosia following lesions to either of these regions in the right hemisphere cannot identify faces, but can still detect faces. Here we acquired functional magnetic resonance imaging (fMRI) data during face processing in a patient presenting a specific deficit in individual face recognition, following lesions encompassing the right IOG. Using an adaptation paradigm we show that the fMRI signal in the rMFG of the patient, while being larger in response to faces as compared to objects, does not differ between conditions presenting identical and distinct faces, in contrast to the larger response to distinct faces observed in controls. These results suggest that individual discrimination of faces critically depends on the integrity of both the rMFG and the rIOG, which may interact through re-entrant cortical connections in the normal brain.

Discrimination Learning↗

Functional MRI using multiple receiver coils: BOLD signal changes and signal-to-noise ratio for three-dimensional-PRESTO vs. single shot EPI in comparison to a standard quadrature head coil.

PURPOSE: To compare the performance of single shot echo planar imaging (SSEPI) with three-dimensional-multishot echo-planar imaging (EPI) based on principles-of-echo-shifting-with-a-train-of-observations (PRESTO) in combination with a standard quadrature head coil and, as an alternative, a multiple receiver coil in intraoperative functional magnetic resonance imaging (fMRI). MATERIALS AND METHODS: Six healthy subjects underwent fMRI with visual stimulation using a SSEPI and a PRESTO-sequence with both coil systems. Statistical evaluation was done with a scanner-based post-processing software and SPM 99. The number of activated voxels in the visual cortex, the percent signal change between rest and activation, and finally the signal-to-noise ratio (SNR) during time course were measured and compared for both coil systems and both sequences, used in four different combinations. RESULTS: Blood oxygen level dependent (BOLD) signal changes were the lowest with PRESTO and standard head coil and the highest for SSEPI and phased array coil. For the latter combination, a significantly higher signal change and larger activation size was observed together with a better SNR. SSEPI yielded similar performance using both coils. CONCLUSION: SSEPI was superior due to its better SNR and a higher BOLD signal change in the defined settings, irrespective of the coil used. In a stereotactical setup the phased array coil can be used to generate fMRI data without loss of image quality.

Adult↗

Discriminating the cortical representation sites of tongue and up movement by functional MRI.

PURPOSE: The purpose of this study was to investigate the possibility to discriminate the representation sites of lip and tongue movement in the primary motor cortex (PMC). In contrast to preceding studies this research was particularly focused on single subject analysis. PROCEDURES: Six healthy right-handed volunteers underwent functional magnetic resonance imaging (fMRI) by means of a 1.5 tesla scanner. Using a block design the subjects had to perform two different motor tasks: horizontal tongue movement and symmetrical lip pursing. To ensure that only the functional selective cortical representations for each particular motor task were determined, the approach of contrasting both motor paradigms was followed during data analysis. PRINCIPLE RESULTS: Selective cortex activations for both motor tasks were detectable in the motor strips and could be spatially discriminated for the whole group and for the majority of the single subjects in both hemispheres. Furthermore, expanded regions responsive to both motor tasks were found bilaterally. CONCLUSIONS: The individually proven possibility to differentiate the cortical representation sites of tongue and lip movements opens the chance to monitor therapeutic cortical effects after neuro-reconstructive surgery, e. g. hypoglossal-facial nerve anastomosis (HFA).

Adult↗

Intraoperative functional MRI as a new approach to monitor deep brain stimulation in Parkinson's disease.

This article deals with technical aspects of intraoperative functional magnetic resonance imaging (fMRI) for monitoring the effect of deep brain stimulation (DBS) in a patient with Parkinson's disease. Under motor activation, therapeutic high-frequency stimulation of the subthalamic nucleus was accompanied by an activation decrease in the contralateral primary sensorimotor cortex and the ipsilateral cerebellum. Furthermore, an activation increase in the contralateral basal ganglia and insula region were detected. These findings demonstrate that fMRI constitutes a promising clinical application for investigating brain activity changes induced by DBS.

Aged↗

Human cortical object recognition from a visual motion flowfield.

Moving dots can evoke a percept of the spatial structure of a three-dimensional object in the absence of other visual cues. This phenomenon, called structure from motion (SFM), suggests that the motion flowfield represented in the dorsal stream can form the basis of object recognition performed in the ventral stream. SFM processing is likely to contribute to object perception whenever there is relative motion between the observer and the object viewed. Here we investigate the motion flowfield component of object recognition with functional magnetic resonance imaging. Our SFM stimuli encoded face surfaces and random three-dimensional control shapes with matched curvature properties. We used two different types of an SFM stimulus with the dots either fixed to the surface of the object or moving on it. Despite the radically different encoding of surface structure in the two types of SFM, both elicited strong surface percepts and involved the same network of cortical regions. From early visual areas, this network extends dorsally into the human motion complex and parietal regions and ventrally into object-related cortex. The SFM stimuli elicited a face-selective response in the fusiform face area. The human motion complex appears to have a central role in SFM object recognition, not merely representing the motion flowfield but also the surface structure of the motion-defined object. The motion complex and a region in the intraparietal sulcus reflected the motion state of the SFM-implicit object, responding more strongly when the implicit object was in motion than when it was stationary.

Adult↗