Directional atherectomy of a calcified lesion using a new atherectomy device.

We report on a case of directional atherectomy performed on a calcified coronary lesion using a novel device with a hardened titanium cutter. The successful removal of calcified plaque was documented by intravascular ultrasound assessment and confirmed by histopathological analysis of the obtained plaque specimen.

Atherectomy, Coronary↗

Effective plaque removal with a new 8 French-compatible atherectomy catheter.

The purpose of this study was to evaluate the safety and efficacy of the new 8 Fr guide catheter-compatible Flexicut directional atherectomy device and to compare it with the conventional Atherocath GTO catheter. The 6 Fr Flexicut catheter has a larger cutting window and a titanium nitride-coated cutter to effect more tissue removal as well as treat mildly calcified lesions. A group of 143 lesions in 117 consecutive patients treated with the Flexicut catheter in four centers were compared with a control group of 277 lesions in 212 consecutive patients treated with the GTO device. Postatherectomy luminal diameters were larger (2.92 +/- 0.79 vs. 2.52 +/- 0.64 mm; P < 0.0001), with more luminal gain (relative gain: 0.58 +/- 0.24 vs. 0.48 +/- 0.25; P = 0.0007) using fewer directional coronary atherectomy (DCA) cuts (12 +/- 7 vs. 16 +/- 9; P = 0.0001) in the Flexicut group. A residual diameter stenosis < 20% immediately after DCA was obtained in 77% of the lesions in the Flexicut group vs. 45% in the GTO group (P < 0.0001). Histology in the former group revealed large calcium speckles in the retrieved specimens. In the Flexicut group, there was a lower incidence of access site complications and damage to the coronary ostium (2.5% vs. 7.5%; P = 0.08). The new Flexicut catheter is more effective than the conventional GTO catheter with a trend for reduced guiding catheter-related complications.

Atherectomy, Coronary↗

Cerebral protection during carotid artery stenting: collection and histopathologic analysis of embolized debris.

BACKGROUND AND PURPOSE: Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. METHODS: Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery presenting >70% diameter stenosis (mean, 82.1+/-11.1%). Mean age of the patients was 70.7+/-7.7 years; 75% were men, and 50% of patients had previous neurological symptoms. RESULTS: In 37 lesions (97.4%) it was possible to position the filter device, and in all lesions a stent was successfully implanted. The only complication occurring in the hospital and during the 30-day follow-up was 1 death due to acute myocardial infarction. Neurological sequelae did not occur. Histomorphometric analysis was performed on the filters. Presence of debris was detected in 83.7% of filters. The mean surface area of the polyurethane membrane filter covered with material was 53.2+/-19.8%. Particle size ranged from 1.08 to 5043.5 microm (mean, 289.5+/-512 microm) in the major axis and 0.7 to 1175.3 microm (mean, 119.7+/-186.7 microm) in the minor axis. Collected debris consisted predominantly of thrombotic material, foam cells, and cholesterol clefts. CONCLUSIONS: By the use of distal protection filters during carotid artery stenting, it was possible to collect particulate debris potentially leading to distal vessel occlusion in a high percentage of cases. Qualitative analysis of embolized material showed debris dislocated during the percutaneous intervention from atheromatous plaques.

Aged↗

Elective stenting in small coronary arteries: results of the Italian prospective multicenter registry MICROSCOPE.

BACKGROUND: The role of stent implantation in small coronary arteries is still controversial. The MICROSCOPE study (Ministenting in small coronary arteries, a prospective evaluation) is a multicenter registry addressed to prospectively evaluate the immediate and mid-term clinical and angiographic results of elective stenting of lesions located in coronary arteries with an angiographic reference diameter < or = 2.75 mm. METHODS: A total of 146 patients (160 lesions) were included in the study. The percentage of complex lesions (B2 and C lesions) was 49.3%. The clinical indications for stent implantation were: stable angina (55.0%), unstable angina (24.6%), and clinical evidence of myocardial ischemia in asymptomatic patients (20.4%); 60% of patients had multivessel disease. Stent deployment could be performed in 96.2% of lesions. The baseline reference diameter was 2.12 +/- 0.36 mm. In all cases the Ministent (Cordis, a J&J Company, Miami, FL, USA), specifically designed for small coronary arteries, was employed. The stent was pre-mounted on low profile balloons available in three different diameters (2.25, 2.50 and 2.75 mm) and three different lengths (11, 15 e 26 mm). RESULTS: The primary endpoint of successful stent-assisted angioplasty in all study vessels without major adverse cardiac events was achieved in 95.8% of the patients. The minimal lumen diameter increased from 0.64 +/- 0.24 to 2.02 +/- 0.43 mm and the dimensions of the stenosis (expressed as a percentage of the diameter of the coronary vessel) decreased from 68.6 +/- 10.8 to 16.2 +/- 10.7% (< 30% standard deviation in all cases). After the procedure all the patients received double antiplatelet therapy for 4 weeks. Post-procedural complications were limited to 2 patients (1.3%) who had a non-Q wave myocardial infarction at 6 months of follow-up; 13 patients (11%) required target lesion revascularization. No patient died following the procedure. Angiographic control was performed in 44% of lesions. The minimal lumen diameter decreased to 1.12 +/- 0.47 mm and the percent stenosis increased to 45.9 +/- 23.2%. The incidence of binary restenosis (stenosis > or = 50%) was 41%. CONCLUSIONS: Elective stenting of small coronary arteries with the Ministent can be safely performed and is associated with a low incidence of acute or subacute stent thrombosis. The mid-term results indicate a high rate of angiographic restenosis but a low need of target vessel revascularization. These data suggest that stenting cannot be considered the treatment of choice for unselected lesions located in coronary arteries with a small reference diameter, but represents a safe solution if unsatisfactory results are obtained with balloon angioplasty alone.

Aged↗

Percutaneous endovascular stent-graft placement for the treatment of acute rupture of an aneurysm of the thoracic aorta.

A 68-year-old male patient presented with massive hematemesis following the acute rupture of an aneurysm of the descending thoracic aorta into the esophagus. In view of the important cardiac and pulmonary comorbidities, surgical treatment was excluded and successful percutaneous implantation of an endovascular stent-graft in the descending aorta was performed. In selected patients endovascular treatment may constitute an alternative to the surgical repair of ruptured aortic aneurysms.