Search PubMed⌕ Search

Biomedical subjects

Bernd d'Hoedt

Publications and source records attributed to Bernd d'Hoedt.

16 recordsLinked to original sources

Incidence and predictive factors for perforation of the maxillary antrum in operations to remove upper wisdom teeth: prospective multicentre study.

BACKGROUND: Our aim was to evaluate the incidence of perforations of the sinuses and their related treatment after the removal of upper wisdom teeth depending on various anatomical and clinical variables. MATERIAL AND METHODS: A total of 1057 upper wisdom teeth were removed under local anaesthetic in the departments of oral surgery at the Universities of Bonn, Düsseldorf, Frankfurt and Mainz, Germany. Data were collected with the help of an anonymised questionnaire dealing with information about the patients, and the position and stage of the development of teeth, as well as the occurrence and size of an oro-antral communication and its treatment. RESULTS: Of 465 extractions and 592 osteotomies of the upper third molars, 134 interventions (13%) were related directly to the diagnosis of a perforated maxillary sinus. Acute oro-antral communication occurred as a result of the removal of completely impacted teeth in 88 of 370, (24%) by removal of partially impacted teeth in 23 of 222 (10%) and in fully erupted third molars in 23 of 465 (5%) of all cases. These differences are significant (p<0.001). In 111 (83%), the diameter of the oro-antral perforation was less than 3mm. In 25 (19%) of all sinus openings, a buccal sliding flap was used to close the extraction wound. We conclude that intraoperative fracture of the root, higher degree of impaction and higher age of the patient are associated with a greater likelihood of oro-antral perforation.

Adolescent↗

Epulis granulomatosa as an oral manifestation of Klippel-Trénaunay syndrome.

The Klippel-Trénaunay syndrome (KTS) was first described by Klippel and Trénaunay in 1900. It is characterized by the triad of hemihypertrophy of soft and hard tissue, naevus flammeus and venous varicosity in the affected area. Though all oral tissues may be affected, only 5% of KTS show manifestations in the head and neck region. Only three cases are described with an oral manifestation, showing gingival overgrowth clinically and histologically corresponding to a pyogenic granuloma. It is still uncertain whether the combination of gingival fibromatosis and KTS is significant or coincidental. We report about a 25-year-old patient with KTS and recidivous gingival fibromatosis, clinically and histologically corresponding to an epulis fibromatosa in a case report. It is suggested that this occurrence is significant.

Adult↗

Clinical efficacy of semiconductor laser application as an adjunct to conventional scaling and root planing.

BACKGROUND AND OBJECTIVES: The aim of the in vitro study was to examine the clinical efficacy of semiconductor laser periodontal pocket irradiation as an adjunct to conventional scaling and root planing. MATERIALS AND METHODS: Twenty-two healthy patients with a need of periodontal treatment (15 women, 7 men, mean age 45.0 +/- 10.8 years) with at least four teeth in all quadrants, were included. All of them underwent a conventional periodontal treatment including scaling and root planing. Using a split mouth design, two randomly chosen quadrants (one upper and the corresponding lower one) were subsequently treated with an 809 nm GaAlAs laser operated at a power output of 1.0 Watt using a 0.6 mm optical fiber. The teeth in the control quadrants were rinsed with saline. The clinical outcome was evaluated by means of plaque index (PI), gingival index (GI), bleeding on probing (BOP), sulcus fluid flow rate (SFFR), Periotest (PT), probing pocket depth (PPD), and clinical attachment loss (CAL) at baseline and at 3 months after treatment. A total of 492 teeth in both groups were evaluated and differences between the laser and the control teeth were analyzed using the Wilcoxon test (P < 0.05). RESULTS: Teeth treated with the laser revealed a significantly higher reduction in tooth mobility, pocket depth, and clinical attachment loss. Twelve percent of the teeth in the laser group showed an attachment gain of 3 mm or more, compared to 7% in the control group. An attachment gain of 2-3 mm was found in 24% of the teeth in the laser group and 18% in the control group. No significant group differences, however, could be detected for the plaque index, gingival index, bleeding on probing, and the sulcus fluid flow rate. CONCLUSIONS: The higher reduction in tooth mobility and probing depths is probably not predominantly related to bacterial reduction in the periodontal pockets but to the de-epithelization of the periodontal pockets leading to an enhanced connective tissue attachment. The application of the diode laser in the treatment of inflammatory periodontitis at the irradiation parameters described above is a safe clinical procedure and can be recommended as an adjunct to conventional scaling and root planing.

Adult↗

In vitro evaluation of the biocompatibility of contaminated implant surfaces treated with an Er : YAG laser and an air powder system.

Titanium platelets with a sand-blasted and acid-etched surface were coated with bovine serum albumin and incubated with a suspension of Porphyromonas gingivalis (ATCC 33277). Four groups with a total of 48 specimens were formed. Laser irradiation of the specimens (n = 12) was performed on a computer-controlled XY translation stage at pulse energy 60 mJ and frequency 10 pps. Twelve specimens were treated with an air powder system. After the respective treatment, human gingival fibroblasts were incubated on the specimens. The proliferation rate was determined by means of fluorescence activity of a redox indicator (Alamar Blue Assay) which is reduced by metabolic activity related to cellular growth. Proliferation was determined up to 72 h. Contaminated and non-treated as well as sterile specimens served as positive and negative controls. Proliferation activity was significantly (Mann-Whitney U-test, P < 0.05) reduced on contaminated and non-treated platelets when compared to sterile specimens. Both on laser as well as air powder-treated specimens, cell growth was not significantly different from that on sterile specimens. Air powder treatment led to microscopically visible alterations of the implant surface whereas laser-treated surfaces remained unchanged. Both air powder and Er : YAG laser irradiation have a good potential to remove cytotoxic bacterial components from implant surfaces. At the irradiation parameters investigated, the Er : YAG laser ensures a reliable decontamination of implants in vitro without altering surface morphology.

Adolescent↗

Determination of projection geometry from quantitative assessment of the distortion of spherical references in single-view projection radiography.

A method is introduced, inferring the three-dimensional (3-D) location from the 2-D radiographic shadow of an opaque spherical reference body of known radius by considering its elliptical distortion, the 2-D shadow location and a known source-to-receptor distance. Three noncollinear spheres fixed to a rigid object constitute all possible degrees of freedom, i.e., the entire 3-D imaging geometry. The method may be used (a) to determine the 3-D imaging geometry from a single 2-D view and (b) to correct for foreshortening of object distances coplanar with the plane defined by the sphere triplet. Apart from the mathematical background the article describes a small feasibility experiment, performed with four different sphere diameters and a commercial dental ccd-receptor system (pixel length: 0.0195 mm). The mouse-cursor based image evaluation revealed an average underestimation of the critical depth- (x-) coordinate decreasing with increasing radius (-30.3% for r=0.5 mm to 2.8% for r=2.5 mm). Intraobserver reliability (the standard deviation between three single cursor-based assessments) ranged between 0% and 8% of the actual true depth. The main source of the input error is associated with the assessment of the amount of elliptical distortion, where subpixel accuracy is demanded. Consequently, software-based automated image evaluation is required using available methods for pattern recognition and point-spread correction. Provided sufficient accuracy, the method provides an important tool for foreshortening correction, depth assessment, motion analysis, and 3-D reconstruction from two or more 2-D views.

Algorithms↗

Effect of low-level GaAlAs laser irradiation on the proliferation rate of human periodontal ligament fibroblasts: an in vitro study.

AIM: The aim of this in vitro study was to evaluate a potential stimulatory effect of low-level laser irradiation on the proliferation of human periodontal ligament fibroblasts (PDLF). MATERIALS AND METHODS: PDLF obtained from third molar periodontal ligaments were cultured under standard conditions and spread on 96-well tissue culture plates. Subconfluent monolayers were irradiated with an 809-nm diode laser operated at a power output of 10 mW in the continuous wave (cw) mode at energy fluences of 1.96-7.84 Jcm-2. The variable irradiation parameters were the time of exposure (75-300 s per well) and the number of irradiations (1-3). After laser treatment, the cultures were incubated for 24 h. The proliferation rate of the lased and control cultures was determined by means of fluorescence activity of a reduction-oxidation (REDOX) indicator (Alamar Blue Assay) added to the cell culture. Proliferation, expressed in relative fluorescence units (RFU), was determined 24, 48 and 72 h after irradiation. RESULTS: The irradiated cells revealed a considerably higher proliferation activity than the controls. The differences were significant up to 72 h after irradiation (Mann-Whitney U-test, p<0.05). CONCLUSION: A cellular effect of the soft laser application is clearly discernible. Clinical studies are needed to evaluate whether the application of low-level laser therapy might be beneficial in regenerative periodontal therapy.

Aluminum↗

Effect of simulated CO2 and GaAlAs laser surface decontamination on temperature changes in Ti-plasma sprayed dental implants.

BACKGROUND AND OBJECTIVE: To investigate and compare temperature elevations at the implant-bone interface during simulated implant surface decontamination with a CO2 and a GaAlAs laser. STUDY DESIGN/MATERIALS AND METHODS: Stepped cylinder implants (Frialit 2) Friadent GmbH, Mannheim, Germany) with a Titanium plasma sprayed surface were inserted into bone blocks cut from pig femurs. An artificial periimplant bone defect provided access for laser irradiation in the coronal third. Both lasers were operated at 1.0-2.5 W in the cw-mode. The bone block was placed into a 37 degrees C water bath in order to simulate in vivo thermal conductivity and diffusitivity of heat. K-type thermocouples connected to a digital meter were used to register temperature changes at the periimplant bone. RESULTS: In mean, the critical threshold of 47 degrees C was exceeded after 8 seconds at a power output of 2.5 W, 13 seconds at 2.0 W, 18 seconds at 1.5 W, and 42 seconds at 1.0 W with the GaAlAs laser and 15 seconds (2.5 W), 23 seconds (2.0 W), 35 seconds (1.5 W), and 56 seconds (1.0 W) with the CO2 laser. At equal energy fluence, GaAlAs laser irradiation induced significantly higher temperature elevations than CO2 laser irradiation. CONCLUSIONS: In an energy dependent manner implant surface decontamination with both laser types must be limited in time to allow the implant and bone to cool down. Clinical guidelines are presented to avoid tissue damage.

Animals↗

Low level 809-nm diode laser-induced in vitro stimulation of the proliferation of human gingival fibroblasts.

BACKGROUND AND OBJECTIVE: The authors investigated the effects of low level laser irradiation on the proliferation rate of human gingival fibroblasts (HGF) in vitro. STUDY DESIGN/MATERIALS AND METHODS: HGF were obtained from gingival connective tissue explants and cultured under standard conditions. 110 cell cultures in their logarithmic growth phase were spread on 96-well tissue culture plates and were irradiated at energy fluences of 1.96-7.84 J/cm(2). Another 110 cultures served as control. An 809-nm semiconductor laser operated at a power output of 10 mW in the cw-mode was used. The time of exposure varied between 75 and 300 seconds. Laser treatment was performed alternatively once, twice, and three times at a 24-hour interval. After lasing, incubation was continued for 24 hours. The proliferation rate was determined by means of fluorescence activity of a redox indicator added to the cell culture. Proliferation was determined 24, 48, and 72 hours after irradiation and expressed in relative fluorescence units (RFU). RESULTS: The irradiated cells revealed a considerably higher proliferation activity. The differences were highly significant 24 hour after irradiation (Mann-Whitney U-test, P < 0.05) but decreased in an energy-dependent manner after 48 and 72 hour after irradiation. CONCLUSIONS: A cellular effect of the soft laser irradiation on HGF is evident. Its duration, however, seems to be limited. These findings might be clinically relevant, indicating that repeated treatments are necessary to achieve a positive laser effect in clinical applications.

Cells, Cultured↗

Randomized multicenter comparison of two coatings of intramobile cylinder implants in 313 partially edentulous mandibles followed up for 5 years.

Intramobile cylinder (IMZ) implants with either of two coatings, hydroxyapatite (HA) or titanium plasma-flame (TPF), as distal abutments for combined tooth implant-supported restorations, were compared in 313 partially edentulous mandibles with respect to postprosthetical failure patterns and complication frequencies in a randomized multicenter clinical trial. Within the treatment protocols, the two coatings do not show evidence of different efficacy with respect to occurrence of postprosthetical integration deficiency (ID) or functional deficiency (FD). Statistical equivalence for an absolute effect of +/-15% in event-free survival could only be demonstrated for FD, not for ID, however. Intent-to-treat and per-protocol population analyses gave consistent results. Hazards of occurrence of ID and FD, adjusted for years of follow-up, were estimated for ID as 7% per year (95%CI 4-10% per year) with HA and 5% per year (95%CI 3-7% per year) with TPF, and for FD as 5% per year (95%CI 3-7% per year) with HA and 4% per year (95%CI 2-6% per year) with TPF. The 5-year cumulative success rates for no ID were 69.5% (95%CI 58-81%) with HA and 82.2% (95%CI 74-91%) with TPF. With respect to frequencies of complications, there was no relevant statistically significant difference between the two coatings.

Adult↗

B-mode versus A-mode ultrasonographic measurements of mucosal thickness in vivo.

OBJECTIVE: The objective of this study was to compare the measurement accuracy of A-mode and B-mode ultrasonographic assessments of palatal masticatory mucosal thickness in vivo. STUDY DESIGN: Thickness of palatal masticatory mucosa in the molar region of 50 volunteers was measured once with a B-mode ultrasound device (10 MHz) combined with a standoff for intraoral applications. At identical reading points thickness was also assessed with an A-mode device (5 replicates) and by needle probing for determination of true thickness. RESULTS: On average true thickness ranged between 2.9 and 3.3 mm (95% confidence intervals; median, 3.1 mm). B-mode ultrasonography overestimated truth by 0.19 mm (median) and differed significantly from truth (P =.008), whereas A-mode ultrasonography slightly underestimated true thickness by -0.05 mm (median). Limits of agreement were wider for A-mode ultrasonography (2.00 mm) than for B-mode ultrasonography (0.88 mm). CONCLUSIONS: Because accuracy of 0.2 mm is acceptable for many clinical indications, B-mode and A-mode yield sufficient accuracy for measurements of mucosal thickness.

Humans↗

Bactericidal effect of the Er:YAG laser on dental implant surfaces: an in vitro study.

BACKGROUND: The aim of the in vitro study was to examine the bactericidal effect of an Er:YAG laser on common dental implant surfaces. METHODS: Seventy-two titanium platelets with 3 different surfaces--sandblasted and acid-etched (SA), titanium plasma-sprayed (TPS), and hydroxyapatite-coated (HA)--were incubated with a suspension of Streptococcus sanguinis (ATCC 10556). Irradiation at pulse energies of 60 and 120 mJ and a frequency of 10 pps was performed on a computer-controlled XY translation stage. After laser treatment the specimens were sonicated and the bacterial growth examined by counting colony forming units on blood agar plates. Temperature elevations during irradiation were investigated using K-type thermocouples. Laser treated implant surfaces were analyzed by means of electron microscopy. RESULTS: Compared to non-irradiated specimens, mean bacterial reductions of 99.51% (SA), 98.39% (HA), and 99.6% (TPS) at a pulse energy of 60 mJ and 99.92% (SA), 99.85% (HA), and 99.94% (TPS) at 120 mJ were calculated. At these laser parameters, no excessive temperature elevations or morphological implant surface alterations were detected. CONCLUSIONS: Even at low energy densities, the Er:YAG laser has a high bactericidal potential on common implant surfaces. Clinical studies are justified to evaluate the applicability and efficacy of the Er:YAG laser in the treatment of peri-implantitis.

Acid Etching, Dental↗

Temperature changes at the implant-bone interface during simulated surface decontamination with an Er:YAG laser.

PURPOSE: This study investigated temperature changes at the implant-bone interface during simulated implant surface decontamination with an Er:YAG laser. MATERIALS AND METHODS: Stepped cylinder implants with three different surfaces (titanium plasma sprayed, sandblasted and acid etched, and hydroxyapatite coated) were placed in bone blocks cut from freshly resected pig femurs. An artificial periimplant bone defect with a size of 6 mm2 provided access for laser irradiation in the coronal third of the implant. A 540-pm periimplantitis application tip was used at a distance of 0.5 mm from the implant surface. Pulse energy was varied between 60 and 120 mJ at 10 pps. The bone block was placed into a 37 degrees C water bath to simulate in vivo thermal conductivity and diffusitivity of heat. K-type thermocouples connected to a digital meter were used to register temperature changes at three levels of the periimplant bone. RESULTS: The temperature at the implant-bone interface did not exceed 47 degrees C after 120 seconds of continuing laser irradiation. Temperature elevations were significantly higher at the hydroxyapatite-coated implants than in the two titanium surface groups (P < .001). CONCLUSION: Decontamination of implant surfaces by means of the Er:YAG laser did not excessively heat the periimplant bone within the energy range investigated. This technique therefore seems clinically safe, at least when used with the surfaces studied.

Acid Etching, Dental↗

A 5-year longitudinal study of the clinical effectiveness of ITI solid-screw implants in the treatment of mandibular edentulism.

PURPOSE: The aim of this longitudinal study was to gain 5-year clinical documentation of the 1-stage surgical technique in connection with ITI solid-screw implants used in the edentulous mandible. MATERIALS AND METHODS: One hundred patients with totally edentulous mandibles were treated with bar-retained overdentures supported by a total of 340 consecutively placed ITI solid-screw implants. The patients were followed at annual intervals for at least 5 years to evaluate implant success, longitudinal reactions of the peri-implant hard and soft tissues, and incidences of biologic and mechanical complications. RESULTS: During the trial period, a total of 4 implants failed, all prior to loading, and 51 implants were lost to follow-up, resulting in a cumulative survival rate of 98.8% after 5 years of functional service. The success analysis included additional strictly defined events (either "first occurrence of marginal bone loss > or = 4 mm" or "first occurrence of pocket depth > or = 4 mm" and "first occurrence of crevicular fluid flow rate > or = 2.5 mm) and resulted in a cumulative 5-year success rate of 95.7%. The median marginal bone loss experienced between implant placement and prosthetic treatment was 0.5 mm, followed by an annual bone level change of 0.1 mm for the functional period of 5 years. The increasing incidence of remarkable plaque deposits from 19% to 50% represented the difficulties of the patients in maintaining a high level of oral hygiene, particularly for the lingual surfaces. Sulcus Bleeding Index, probing depth, attachment level, and crevicular fluid flow rate were used to describe the health of the peri-implant soft tissues and remained almost within acceptable standards. DISCUSSION: Survival and success rates of implants, amount of marginal bone loss, and periodontal indices of peri-implant soft tissues were consistent with those reported in the literature regarding implants with the submerged healing concept. CONCLUSION: With a cumulative survival rate of 98.8%, a cumulative success rate of 95.7%, and a median marginal bone loss of 0.5 mm during the healing period, followed by an annual rate of 0.1 mm after loading, non-submerged ITI solid-screw implants confirm the good clinical outcome of implant-supported treatment concepts for the rehabilitation of totally edentulous patients in a medium-term perspective.

Adult↗

Residual ridge resorption in the edentulous maxilla in patients with implant-supported mandibular overdentures: an 8-year retrospective study.

PURPOSE: This retrospective study radiologically investigated alveolar bone resorption in the edentulous maxilla in patients with implant-supported mandibular overdentures. MATERIALS AND METHODS: This study consisted of 35 healthy, completely edentulous patients with a mean age of 59.7 years. They had received two implants between the mental foramina. New bar-retained mandibular overdentures and maxillary complete dentures were fabricated. Standardized panoramic radiographs taken subsequent to loading and at annual recall visits for up to 8 years were measured for alveolar bone loss in the maxilla. Bone areas and areas of reference not subject to resorption were measured with a planimetry program. The proportional value between both was expressed as a ratio (R). Bone loss was expressed as a change in R between two time points. Differences in the resorption rate between the anterior and posterior parts of the maxilla were investigated. RESULTS: Residual ridge resorption continued during the follow-up period and revealed high individual variability. With a range of 5% to 11% (median) loss in the original bone height, it was significantly (P < .031) more pronounced in the anterior than posterior maxilla (2% to 7%) from the second through eighth years. Regression analysis of the medians revealed a relatively high correlation between time and bone loss in both anterior and posterior parts of the maxilla. CONCLUSION: The anterior anchorage of mandibular overdentures by means of two implants and an ovoid bar was associated with slightly higher resorption in the anterior than in the posterior part of the edentulous maxilla.

Alveolar Bone Loss↗

Antimicrobial efficacy of semiconductor laser irradiation on implant surfaces.

PURPOSE: This study was conducted to investigate the antimicrobial effect of an 809-nm semiconductor laser on common dental implant surfaces. MATERIALS AND METHODS: Sandblasted and acid-etched (SA), plasma-sprayed (TPS), and hydroxyapatite-coated (HA) titanium disks were incubated with a suspension of S. sanguinis (ATCC 10556) and subsequently irradiated with a gallium-aluminum-arsenide (GaAlAs) laser using a 600-microm optical fiber with a power output of 0.5 to 2.5 W, corresponding to power densities of 176.9 to 884.6 W/cm2. Bacterial reduction was calculated by counting colony-forming units on blood agar plates. Cell numbers were compared to untreated control samples and to samples treated with chlorhexidine digluconate (CHX). Heat development during irradiation of the implants placed in bone blocks was visualized by means of shortwave thermography. RESULTS: In TPS and SA specimens, laser irradiation led to a significant bacterial reduction at all power settings. In an energy-dependent manner, the number of viable bacteria was reduced by 45.0% to 99.4% in TPS specimens and 57.6% to 99.9% in SA specimens. On HA-coated disks, a significant bacterial kill was achieved at 2.0 W (98.2%) and 2.5 W (99.3%) only (t test, P < .05). For specimens treated with CHX, the bacterial counts were reduced by 99.99% in TPS and HA-coated samples and by 99.89% in SA samples. DISCUSSION: The results of the study indicate that the 809-nm semiconductor laser is capable of decontaminating implant surfaces. Surface characteristics determine the necessary power density to achieve a sufficient bactericidal effect. The bactericidal effect, however, was lower than that achieved by a 1-minute treatment with 0.2% CHX. The rapid heat generation during laser irradiation requires special consideration of thermal damage to adjacent tissues. CONCLUSION: No obvious advantage of semiconductor laser treatment over conventional methods of disinfection could be detected in vitro.

Acid Etching, Dental↗

Randomized multicenter comparison of 2 IMZ and 4 TPS screw implants supporting bar-retained overdentures in 425 edentulous mandibles.

PURPOSE: Two treatment concepts for implant-supported bar retention of mandibular overdentures-2 intramobile cylinder (IMZ) implants and a Dolder bar and 4 titanium plasma-sprayed (TPS) screw implants and an angulated bar-were compared in a randomized controlled clinical trial with respect to postprosthetic efficacy and safety. MATERIALS AND METHODS: Four hundred twenty-five patients with edentulous mandibles were enrolled; 212 were randomized to TPS implants (control group) and 213 to IMZ implants (test group). Endpoints were occurrences of postprosthetic integration deficiency (ID), functional deficiency (FD), and complications. The trial was sized to detect a 10% difference in 5-year ID-free postprosthetic system lifetime with a power of 80%. RESULTS: With 340 protocol-completed cases, the trial achieved its predetermined power. The 2 systems did not show statistically significant differences in occurrences of postprosthetic ID and FD; 5-year occurrence-free postprosthetic system lifetime probabilities were estimated as 42.5% with IMZ and 42.8% with TPS, for ID; and as 82.6% with IMZ and 87.2% with TPS, for FD. However, at 3 to 6 months after surgery, mean Periotest values were significantly higher (P = .0001 without adjustment) with IMZ implants (5.6, SD 4.2) than with TPS implants (0.8, SD 4.3). TPS implants showed a higher incidence of inflammation and recession, while IMZ implants had a higher incidence of implant fracture after functional loading. DISCUSSION: The system-wise approach overcomes potential bias with implant-wise analyses. A combination of radiographic and clinical criteria distinguishes between desirable integration and functional anchorage. The in situ survival rates at 5 years in this study (95% for IMZ, 92% for TPS) match rates reported in the literature. CONCLUSION: This study demonstrated equivalent efficacy of 2 IMZ cylinders and 4 TPS screws in implant-supported, bar-retained mandibular overdentures and indicated a higher rate of complications with the TPS screw implants.

Adult↗