Search PubMed⌕ Search

Biomedical subjects

Bernard Chiu

Publications and source records attributed to Bernard Chiu.

2 recordsLinked to original sources

Prostate contouring uncertainty in megavoltage computed tomography images acquired with a helical tomotherapy unit during image-guided radiation therapy.

PURPOSE: To evaluate the image-guidance capabilities of megavoltage computed tomography (MVCT), this article compares the interobserver and intraobserver contouring uncertainty in kilovoltage computed tomography (KVCT) used for radiotherapy planning with MVCT acquired with helical tomotherapy. METHODS AND MATERIALS: Five prostate-cancer patients were evaluated. Each patient underwent a KVCT and an MVCT study, a total of 10 CT studies. For interobserver variability analysis, four radiation oncologists, one physicist, and two radiation therapists (seven observers in total) contoured the prostate and seminal vesicles (SV) in the 10 studies. The intraobserver variability was assessed by asking all observers to repeat the contouring of 1 patient's KVCT and MVCT studies. Quantitative analysis of contour variations was performed by use of volumes and radial distances. RESULTS: The interobserver and intraobserver contouring uncertainty was larger in MVCT compared with KVCT. Observers consistently segmented larger volumes on MVCT where the ratio of average prostate and SV volumes was 1.1 and 1.2, respectively. On average (interobserver and intraobserver), the local delineation variability, in terms of standard deviations [Deltasigma = radical(sigma2MVCT-sigma2KVCT)], increased by 0.32 cm from KVCT to MVCT. CONCLUSIONS: Although MVCT was inferior to KVCT for prostate delineation, the application of MVCT in prostate radiotherapy remains useful.

Humans↗

Prostate segmentation algorithm using dyadic wavelet transform and discrete dynamic contour.

Knowing the location and the volume of the prostate is important for ultrasound-guided prostate brachytherapy, a commonly used prostate cancer treatment method. The prostate boundary must be segmented before a dose plan can be obtained. However, manual segmentation is arduous and time consuming. This paper introduces a semi-automatic segmentation algorithm based on the dyadic wavelet transform (DWT) and the discrete dynamic contour (DDC). A spline interpolation method is used to determine the initial contour based on four user-defined initial points. The DDC model then refines the initial contour based on the approximate coefficients and the wavelet coefficients generated using the DWT. The DDC model is executed under two settings. The coefficients used in these two settings are derived using smoothing functions with different sizes. A selection rule is used to choose the best contour based on the contours produced in these two settings. The accuracy of the final contour produced by the proposed algorithm is evaluated by comparing it with the manual contour outlined by an expert observer. A total of 114 2D TRUS images taken for six different patients scheduled for brachytherapy were segmented using the proposed algorithm. The average difference between the contour segmented using the proposed algorithm and the manually outlined contour is less than 3 pixels.

Algorithms↗