Correlation between mammographic density and volumetric fibroglandular tissue estimated on breast MR images.

Previous studies have found that mammographic breast density is highly correlated with breast cancer risk. Therefore, mammographic breast density may be considered as an important risk factor in studies of breast cancer treatments. In this paper, we evaluated the accuracy of using mammograms for estimating breast density by analyzing the correlation between the percent mammographic dense area and the percent glandular tissue volume as estimated from MR images. A dataset of 67 cases having MR images (coronal 3-D SPGR T1-weighted pre-contrast) and corresponding 4-view mammograms was used in this study. Mammographic breast density was estimated by an experienced radiologist and an automated image analysis tool, Mammography Density ESTimator (MDEST) developed previously in our laboratory. For the estimation of the percent volume of fibroglandular tissue in breast MR images, a semiautomatic method was developed to segment the fibroglandular tissue from each slice. The tissue volume was calculated by integration over all slices containing the breast. Interobserver variation was measured for 3 different readers. It was found that the correlation between every two of the three readers for segmentation of MR volumetric fibroglandular tissue was 0.99. The correlations between the percent volumetric fibroglandular tissue on MR images and the percent dense area of the CC and MLO views segmented by an experienced radiologist were both 0.91. The correlation between the percent volumetric fibroglandular tissue on MR images and the percent dense area of the CC and MLO views segmented by MDEST was 0.91 and 0.89, respectively. The root-mean-square (rms) residual ranged from 5.4% to 6.3%. The mean bias ranged from 3% to 6%. The high correlation indicates that changes in mammographic density may be a useful indicator of changes in fibroglandular tissue volume in the breast.

Absorptiometry, Photon↗

An observer study comparing spot imaging regions selected by radiologists and a computer for an automated stereo spot mammography technique.

We are developing an automated stereo spot mammography technique for improved imaging of suspicious dense regions within digital mammograms. The technique entails the acquisition of a full-field digital mammogram, automated detection of a suspicious dense region within that mammogram by a computer aided detection (CAD) program, and acquisition of a stereo pair of images with automated collimation to the suspicious region. The latter stereo spot image is obtained within seconds of the original full-field mammogram, without releasing the compression paddle. The spot image is viewed on a stereo video display. A critical element of this technique is the automated detection of suspicious regions for spot imaging. We performed an observer study to compare the suspicious regions selected by radiologists with those selected by a CAD program developed at the University of Michigan. True regions of interest (TROIs) were separately determined by one of the radiologists who reviewed the original mammograms, biopsy images, and histology results. We compared the radiologist and computer-selected regions of interest (ROIs) to the TROIs. Both the radiologists and the computer were allowed to select up to 3 regions in each of 200 images (mixture of 100 CC and 100 MLO views). We computed overlap indices (the overlap index is defined as the ratio of the area of intersection to the area of interest) to quantify the agreement between the selected regions in each image. The averages of the largest overlap indices per image for the 5 radiologist-to-computer comparisons were directly related to the average number of regions per image traced by the radiologists (about 50% for 1 region/image, 84% for 2 regions/image and 96% for 3 regions/image). The average of the overlap indices with all of the TROIs was 73% for CAD and 76.8% +/- 10.0% for the radiologists. This study indicates that the CAD determined ROIs could potentially be useful for a screening technique that includes stereo spot mammography imaging.

Biophysical Phenomena↗

Computerized nipple identification for multiple image analysis in computer-aided diagnosis.

Correlation of information from multiple-view mammograms (e.g., MLO and CC views, bilateral views, or current and prior mammograms) can improve the performance of breast cancer diagnosis by radiologists or by computer. The nipple is a reliable and stable landmark on mammograms for the registration of multiple mammograms. However, accurate identification of nipple location on mammograms is challenging because of the variations in image quality and in the nipple projections, resulting in some nipples being nearly invisible on the mammograms. In this study, we developed a computerized method to automatically identify the nipple location on digitized mammograms. First, the breast boundary was obtained using a gradient-based boundary tracking algorithm, and then the gray level profiles along the inside and outside of the boundary were identified. A geometric convergence analysis was used to limit the nipple search to a region of the breast boundary. A two-stage nipple detection method was developed to identify the nipple location using the gray level information around the nipple, the geometric characteristics of nipple shapes, and the texture features of glandular tissue or ducts which converge toward the nipple. At the first stage, a rule-based method was designed to identify the nipple location by detecting significant changes of intensity along the gray level profiles inside and outside the breast boundary and the changes in the boundary direction. At the second stage, a texture orientation-field analysis was developed to estimate the nipple location based on the convergence of the texture pattern of glandular tissue or ducts towards the nipple. The nipple location was finally determined from the detected nipple candidates by a rule-based confidence analysis. In this study, 377 and 367 randomly selected digitized mammograms were used for training and testing the nipple detection algorithm, respectively. Two experienced radiologists identified the nipple locations which were used as the gold standard. In the training data set, 301 nipples were positively identified and were referred to as visible nipples. Seventy six nipples could not be positively identified and were referred to as invisible nipples. The radiologists provided their estimation of the nipple locations in the latter group for comparison with the computer estimates. The computerized method could detect 89.37% (269/301) of the visible nipples and 69.74% (53/76) of the invisible nipples within 1 cm of the gold standard. In the test data set, 298 and 69 of the nipples were classified as visible and invisible, respectively. 92.28% (275/298) of the visible nipples and 53.62% (37/69) of the invisible nipples were identified within 1 cm of the gold standard. The results demonstrate that the nipple locations on digitized mammograms can be accurately detected if they are visible and can be reasonably estimated if they are invisible. Automated nipple detection will be an important step towards multiple image analysis for CAD.

Algorithms↗

Effects of magnification and zooming on depth perception in digital stereomammography: an observer performance study.

We are evaluating the application of stereoscopic imaging to digital mammography. In the current study, we investigated the effects of magnification and zooming on depth perception. A modular phantom was designed which contained six layers of 1-mm-thick Lexan plates, each spaced 1 mm apart. Eight to nine small, thin nylon fibrils were pasted on each plate in horizontal or vertical orientations such that they formed 25 crossing fibril pairs in a projected image. The depth separation between each fibril pair ranged from 2 to 10 mm. A change in the order of the Lexan plates changed the depth separation of the two fibrils in a pair. Stereoscopic image pairs of the phantom were acquired with a GE full-field digital mammography system. Three different phantom configurations were imaged. All images were obtained using a Rh target/Rh filter spectrum at 30 kVp tube potential and a +/- 3 stereo shift angle. Images were acquired in both contact and 1.8X magnification geometry and an exposure range of 4 to 63 mAs was employed. The images were displayed on a Barco monitor driven by a Metheus stereo graphics board and viewed with LCD stereo glasses. Five observers participated in the study. Each observer visually judged whether the vertical fibril was in front of or behind the horizontal fibril in each fibril pair. It was found that the accuracy of depth discrimination increased with increasing fibril depth separation and x-ray exposure. The accuracy was not improved by electronic display zooming of the contact stereo images by 2X. Under conditions of high noise (low mAs) and small depth separation between the fibrils, the observers' depth discrimination ability was significantly better in stereo images acquired with geometric magnification than in images acquired with a contact technique and displayed with or without zooming. Under our experimental conditions, a 2 mm depth discrimination was achieved with over 60% accuracy on contact images with and without zooming, and with over 90% accuracy on magnification images. This study indicates that stereoscopic imaging, especially with magnification, may be useful for visualizing the spatial distribution of microcalcifications in a cluster and for differentiating overlapping tissues from masses on mammograms.

Breast↗

Optimal neural network architecture selection: improvement in computerized detection of microcalcifications.

RATIONALE AND OBJECTIVES: The authors evaluated the effect of optimal neural network architecture selection on the performance of a computer-aided diagnostic system designed to detect microcalcification clusters on digitized mammograms. MATERIALS AND METHODS: The authors developed a computer program to detect microcalcification clusters automatically on digitized mammograms. Previously, they found that a properly selected and trained convolution neural network (CNN) could reduce false-positive (FP) findings and therefore improve the accuracy of microcalcification detection. In the current study, they evaluated the effectiveness of the CNN optimized with an automated optimization technique in improving the accuracy of the microcalcification detection program, comparing it with the manually selected CNN. An independent test data set was used, which included 472 mammograms selected from the University of South Florida public database and contained 253 biopsy-proved malignant clusters. RESULTS: At an FP rate of 0.7 cluster per image, the film-based sensitivity was 84.6% for the optimized CNN, compared with 77.2% for the manually selected CNN. For clusters imaged on both craniocaudal and mediolateral oblique views, a cluster could be considered detected when it was detected on one or both views. For this case-based approach, at an FP rate of 0.7 per image, the sensitivity was 93.3% for the optimized and 87.0% for the manually selected CNN. CONCLUSION: The classification of true and false signals is an important step in the microcalcification detection program. An optimized CNN can effectively reduce FP findings and improve the accuracy of the computer-aided detection system.

Breast Neoplasms↗

Improvement of computerized mass detection on mammograms: fusion of two-view information.

Recent clinical studies have proved that computer-aided diagnosis (CAD) systems are helpful for improving lesion detection by radiologists in mammography. However, these systems would be more useful if the false-positive rate is reduced. Current CAD systems generally detect and characterize suspicious abnormal structures in individual mammographic images. Clinical experiences by radiologists indicate that screening with two mammographic views improves the detection accuracy of abnormalities in the breast. It is expected that the fusion of information from different mammographic views will improve the performance of CAD systems. We are developing a two-view matching method that utilizes the geometric locations, and morphological and textural features to correlate objects detected in two different views using a prescreening program. First, a geometrical model is used to predict the search region for an object in a second view from its location in the first view. The distance between the object and the nipple is used to define the search area. After pairing the objects in two views, textural and morphological characteristics of the paired objects are merged and similarity measures are defined. Linear discriminant analysis is then employed to classify each object pair as a true or false mass pair. The resulting object correspondence score is combined with its one-view detection score using a fusion scheme. The fusion information was found to improve the lesion detectability and reduce the number of FPs. In a preliminary study, we used a data set of 169 pairs of cranio-caudal (CC) and mediolateral oblique (MLO) view mammograms. For the detection of malignant masses on current mammograms, the film-based detection sensitivity was found to improve from 62% with a one-view detection scheme to 73% with the new two-view scheme, at a false-positive rate of 1 FP/image. The corresponding cased-based detection sensitivity improved from 77% to 91%.

Algorithms↗

Lung nodule detection on thoracic computed tomography images: preliminary evaluation of a computer-aided diagnosis system.

We are developing a computer-aided diagnosis (CAD) system for lung nodule detection on thoracic helical computed tomography (CT) images. In the first stage of this CAD system, lung regions are identified by a k-means clustering technique. Each lung slice is classified as belonging to the upper, middle, or the lower part of the lung volume. Within each lung region, structures are segmented again using weighted k-means clustering. These structures may include true lung nodules and normal structures consisting mainly of blood vessels. Rule-based classifiers are designed to distinguish nodules and normal structures using 2D and 3D features. After rule-based classification, linear discriminant analysis (LDA) is used to further reduce the number of false positive (FP) objects. We performed a preliminary study using 1454 CT slices from 34 patients with 63 lung nodules. When only LDA classification was applied to the segmented objects, the sensitivity was 84% (53/63) with 5.48 (7961/1454) FP objects per slice. When rule-based classification was used before LDA, the free response receiver operating characteristic (FROC) curve improved over the entire sensitivity and specificity ranges of interest. In particular, the FP rate decreased to 1.74 (2530/1454) objects per slice at the same sensitivity. Thus, compared to FP reduction with LDA alone, the inclusion of rule-based classification lead to an improvement in detection accuracy for the CAD system. These preliminary results demonstrate the feasibility of our approach to lung nodule detection and FP reduction on CT images.

Adolescent↗

Breast cancer detection: evaluation of a mass-detection algorithm for computer-aided diagnosis -- experience in 263 patients.

PURPOSE: To evaluate the performance of a computer-aided diagnosis (CAD) mass-detection algorithm in marking preoperative masses. MATERIALS AND METHODS: Digitized mammograms were processed with an adaptive enhancement filter followed by a local border refinement stage. Features were then extracted from each detected structure and used to identify potential masses. The performance of the algorithm was evaluated in independent cases obtained from 263 patients from two institutions. Each case contained one or more pathologically proved breast masses. Contralateral mammograms obtained in the same patients that did not contain a visible lesion were used to estimate the CAD marker rate for the algorithm. The tradeoff between detection sensitivity and the number of CAD marks was analyzed in this study. RESULTS: Malignant masses were detected with the computer in 87% (135 of 156), 83% (130 of 156), and 77% (120 of 156) of the malignant cases at CAD marker rates of 1.5, 1.0, and 0.5 marks per mammogram, respectively. The difference between malignant mass-detection performance in subsets of cases collected at each institution was found to be less than 1%. The detection accuracy for benign masses was lower than that for malignant masses. CONCLUSION: This mass-detection algorithm had a high sensitivity for detection of malignant masses. It may be useful as a second opinion in mammographic interpretation.

Algorithms↗