Search PubMed⌕ Search

Biomedical subjects

Ben A Brooksby

Publications and source records attributed to Ben A Brooksby.

3 recordsLinked to original sources

Effects of refractive index on near-infrared tomography of the breast.

Near infrared (NIR) optical tomography is an imaging technique in which internal images of optical properties are reconstructed with the boundary measurements of light propagation through the medium. Recent advances in instrumentation and theory have led to the use of this method for the detection and characterization of tumors within the female breast tissue. Most image reconstruction approaches have used the diffusion approximation and have assumed that the refractive index of the breast is constant, with a bulk value of approximately 1.4. We have applied a previously reported modified diffusion approximation, in which the refractive index for different tissues can be modeled. The model was used to generate NIR data from a realistic breast geometry containing a localized anomaly. Using this simulated data, we have reconstructed optical images, both with and without correct knowledge of the refractive-index distribution to show that the modified diffusion approximation can accurately recover the anomaly given a priori knowledge of refractive index. But using a reconstruction algorithm without the use of correct a priori information regarding the refractive-index distribution is shown as recovering the anomaly but with a degraded quality, depending on the degree of refractive index mismatch. The results suggest that provided the refractive index of breast tissue is approximately 1.3-1.4, their exclusion will have minimal effect on the reconstructed images.

Algorithms↗

Image analysis methods for diffuse optical tomography.

Three major analytical tools in imaging science are summarized and demonstrated relative to optical imaging in vivo. Standard resolution testing is optimal when infinite contrast is used and hardware evaluation is the goal. However, deep tissue imaging of absorption or fluorescent contrast agents in vivo often presents a different problem, which requires contrast-detail analysis. This analysis shows that the minimum detectable sizes are in the range of 1/10 the outer diameter, whereas minimum detectable contrast values are in the range of 10 to 20% relative to the continuous background values. This is estimated for objects being in the center of the domain being imaged, and as the heterogeneous region becomes closer to the surface, the lower limit on size and contrast can become arbitrarily low and more dictated by hardware specifications. Finally, if human observer detection of abnormalities in the images is the goal, as is standard in most radiological practice, receiver operating characteristic (ROC) curve and location receiver operating characteristic curve (LROC) are used. Each of these three major areas of image interpretation and analysis are reviewed in the context of medical imaging as well as how they are used to quantify the performance of diffuse optical imaging of tissue.

Algorithms↗

Image reconstruction of effective Mie scattering parameters of breast tissue in vivo with near-infrared tomography.

A method for image reconstruction of the effective size and number density of scattering particles is discussed within the context of interpreting near-infrared (NIR) tomography images of breast tissue. An approach to use Mie theory to estimate the effective scattering parameters is examined and applied, given some assumptions about the index of refraction change expected in lipid membrane-bound scatterers. When using a limited number of NIR wavelengths in the reduced scattering spectra, the parameter extraction technique is limited to representing a continuous distribution of scatterer sizes, which is modeled as a simple exponentially decreasing distribution function. In this paper, image formation of effective scatterer size and number density is presented based on the estimation method. The method was evaluated with Intralipid phantom studies to demonstrate particle size estimation to within 9% of the expected value. Then the method was used in NIR patient images, and it indicates that for a cancer tumor, the effective scatterer size is smaller than the background breast values and the effective number density is higher. In contrast, for benign tumor patients, there is not a significant difference in effective scatterer size or number density between tumor and normal tissues. The method was used to interpret magnetic resonance imaging-coupled NIR images of adipose and fibroglandular tissues, and it indicated that the fibroglandular tissue has smaller effective scatterer size and larger effective number density than the adipose tissue does.

Algorithms↗