Search PubMed⌕ Search

Biomedical subjects

Bartłomiej Guzik

Publications and source records attributed to Bartłomiej Guzik.

3 recordsLinked to original sources

[Right ventricular infarction: novel modalities of treatment].

Acute right ventricular infarction (RVI) is usually caused by proximal occlusion of the right coronary artery. RVI is frequent, as it occurs in as many as one out of every two left ventricular interior and/or posterior wall infarctions. The involvement of the right ventricle in acute myocardial infarction has been shown to be associated with an increased risk of life-threatening arrhythmias and sudden cardiac death. Clinical course of RVI can vary from being completely silent to cardiogenic shock (seen in 10-15% patients with inferior wall infarction). RVI diagnosis is based on clinical signs (hypotension and increased jugular venous pressure while pulmonary fields are clear), ECG (ST elevation by > or = 1 mm in V4R), echocardiography (right ventricular wall regional motion abnormalities and/or right ventricle distension, paradoxical motion of the interventricular septum, tissue Doppler), technetium pyrophosphate scanning with ventriculography, and invasive patient monitoring. In addition to its important diagnostic part, the invasive patient monitoring plays a key role in risk stratification and can dynamically guide the treatment (such as fluid loading). In most cases, successful reperfusion in the infarct-related artery territory can be achieved by interventional management (i.e. angioplasty) or--if the latter is not available--by thrombolytic therapy. Patients with arterial hypotension require volume expansion which is best guided by the central venous pressure (CVP; a measure of the right atrial pressure, RAP) and the pulmonary capillary wedge pressure (PCWP). If the hemodynamics does not improve despite optimal fluid loading, pharmacological (catecholamine infusion) or mechanical (intra-aortic balloon pump) circulatory assistance needs to be implemented. Patients with significant sinus bradycardia or 3rd degree AV block may require temporary cardiac pacing. In addition, inhalatory nitric oxide (iNO) has been shown to reduce right ventricular afterload in a selective manner and its potential clinical role is currently being evaluated. Within several months after RVI, the right ventricular performance improves in most patients, including those without successful reperfusion of IRA. Such patients, however, have an increased risk of complications (including sudden death) while the recovery of right ventricular function is slow.

Angioplasty, Balloon, Coronary↗

[False aneurysms after button-Bentall procedure].

Between January 1995 and December 2000, 222 consecutive patients underwent complete aortic root replacement in the Department of Cardiovascular Surgery of the Hertz- und Gefaess- Klinik- Bad Neustadt (Germany). At the exception of 2 cases, all patients received the modified Bentallde Bono procedure with total excision of the ascending aorta and direct reimplantation of the coronary ostia using button technique. During the follow-up period of up to 6 years in 3 patients, a periprosthetic aneurysm was diagnosed. In two patients with clinical symptoms and a fistula between the prosthetic lumen and the spurium aneurysm, a reoperation was performed. Due to the complete absence of clinical symptoms or a fistula connecting the prosthesis and the aneurysm or progress in size of the aneurysm during the follow-up period the third patient was treated conservatively. The choice of proper treatment of this complication is difficult and should be based on continuous investigation of clinical symptoms and various technical examinations.

Aneurysm, False↗

[Complete obliteration of false lumen in thoracic aorta after surgical treatment of acute type De Bakey I aortic dissection--a case report].

A case of a 62 year old male with acute type De Bakey I aortic dissection is presented. The ascending aorta, aortic valve and total aortic arch replacement were performed. Additionally the proximal descending aorta was replaced using elephant trunk technique, to close the entrance of the dissection. There was no patent false lumen in distal descending aorta in postoperative findings.

Acute Disease↗