Search PubMed⌕ Search

Biomedical subjects

Bart J A Mertens

Publications and source records attributed to Bart J A Mertens.

11 recordsLinked to original sources

Detection of colorectal cancer using MALDI-TOF serum protein profiling.

Serum protein profiling is a promising approach for classification of cancer versus non-cancer samples. The objective of our study was to assess the feasibility of mass spectrometry based protein profiling for the discrimination of colorectal cancer (CRC) patients from healthy individuals. In a randomized block design, pre-operative serum samples obtained from 66 colorectal cancer patients and 50 controls were used to generate MALDI-TOF protein profiles. After pre-processing of the spectra, linear discriminant analysis with double cross-validation was used to classify protein profiles. A total recognition rate (92.6%), sensitivity (95.2%) and specificity (90.0%) for the detection of CRC were shown. The area under the curve of the classifier was 97.3%, and demonstrated the high, significant separation power of the classifier. Double cross-validation shows that classification can be attributed to information in the protein profile. Although preliminary, the high sensitivity and specificity indicate the potential usefulness of serum protein profiles for the detection of colorectal cancer.

Adult↗

Mass spectrometry proteomic diagnosis: enacting the double cross-validatory paradigm.

This paper presents an approach to the evaluation and validation of the diagnostic potential of mass spectrometry data in an application on the construction of an "early warning" diagnostic procedure. Our approach is based on a full implementation and application of double cross-validatory calibration and evaluation. It is a key feature of this methodology that we can jointly optimize the classifiers for prediction while simultaneously calculating validated error rates. The methodology leaves the size of the training data nearly intact. We present application to data from a designed experiment in a colon-cancer study. Subsequent to presentation of results from the double cross-validatory analysis, we explore a post-hoc analysis of the calibrated classifiers to identify the markers that drive the classification.

Biometry↗

Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography.

PURPOSE: To determine to what extent dose reduction results in decreased detection of simulated nodules on patient digital posteroanterior (PA) chest radiographs. MATERIALS AND METHODS: Raw data from 20 clinical digital PA chest images that were reported as having normal findings and that were obtained with a slot-scan charge-coupled device system were used. For research protocol that concerns data with patient identities concealed, institutional review board approval is not required. One hundred twenty nodules varying in size and signal intensity were digitally simulated and added to the chest images. Hard copies were printed to represent a 100% dose and, by adding noise, to represent simulated patient doses of 50%, 25%, and 12%. Four radiologists reviewed images. Each lesion was registered as "detected" or "not detected." A semiparametric logistic regression model was used for statistical analysis. RESULTS: The decrease in radiation dose from 100% to 50%, 25%, or 12% had no effect on lesion detection in the lungs. The decrease in radiation dose had an effect on lesion detection in the mediastinum, as probabilities deteriorated from the 100% dose to the 50%, 25%, and 12% dose with each step. Probabilities of smaller detection rates when compared with that of the reference category (100% dose) were 0.97 (95% confidence interval [CI]: -0.86, 0.012) for the 50% dose, 1 (CI: -0.59, -0.61) for the 25% dose, and 1 (CI: -2.41, -1.22) for the 12% dose. CIs for the effects were on the log(odds). Detection probability decreased with smaller and lower signal intensity lesions. CONCLUSION: At clinical digital radiography, dose reduction resulted in decreased observer detection of simulated nodules in the mediastinum but not in the lungs.

Bayes Theorem↗

Contrast-detail evaluation and dose assessment of eight digital chest radiography systems in clinical practice.

The purpose of this study was to assess contrast-detail performance and effective dose of eight different digital chest radiography systems. Digital chest radiography systems from different manufacturers were included: one storage phosphor system, one selenium-coated drum system, and six direct readout systems including four thin-film transistor (TFT) systems and two charge-coupled device (CCD) systems. For measuring image quality, a contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission through lung fields (LucAl). Six observers judged phantom images of each modality by soft-copy reading in a four-alternative-forced-choice experiment. The entrance dose was also measured, and the effective dose was calculated for an average patient. Contrast-detail curves were constructed from the observer data. The blocked two-way ANOVA test was used for statistical analysis. Significant difference in contrast-detail performance was found between the systems. Best contrast-detail performance was shown by a CCD system with slot-scan technology, and the selenium-coated drum system was compared to the other six systems (p values <or=0.003). Calculated effective dose varied between 0.010 mSv and 0.032 mSv. Significant differences in contrast-detail performance and effective dose levels were found between different digital chest radiography systems in clinical practice.

Equipment Design↗

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography: comparison of image quality in a phantom study.

PURPOSE: To evaluate the image quality and performance of a chest digital radiography system and to compare this with the image quality and performance of advanced multiple-beam equalization radiography (AMBER) and Bucky screen-film radiography systems. MATERIALS AND METHODS: The chest digital radiography system is a digital charge-coupled device (CCD) chest imaging unit that uses slot-scan technology. A contrast-detail test object was used in combination with a phantom that simulates the primary and scatter transmission for the lungs and mediastinum. Twelve phantom images were obtained with each modality (ie, CCD digital radiography and AMBER and Bucky screen-film radiography) and were judged by six observers. CCD digital radiography soft-copy reading was compared with AMBER hard-copy reading. To measure image quality, contrast-detail curves were constructed from the observer data. The Wilcoxon signed rank test was used for statistical analysis. RESULTS: For the lung configuration, contrast-detail curves showed lower threshold depth for hard-copy images obtained with CCD digital radiography than for those obtained with Bucky screen-film radiography. For hard-copy images, the difference between contrast-detail curves for CCD digital radiography and those for Bucky screen-film radiography was statistically significant (P < .006). No significant difference was found between CCD digital radiography and AMBER for hard-copy images obtained in either the lung or mediastinum configuration. For the lung configuration, a lower threshold depth was observed for CCD digital radiography soft-copy reading than for AMBER hard-copy reading, with significantly different contrast-detail curves for CCD digital radiography soft copy and AMBER hard copy (P < .006). No significant difference was found between either system for the mediastinum configuration. CONCLUSION: Contrast-detail curves indicate that image quality for the CCD chest system provides a digital alternative to AMBER and Bucky screen-film radiography.

Phantoms, Imaging↗

Comparison of eight different digital chest radiography systems: variation in detection of simulated chest disease.

OBJECTIVE: In a short period, a variety of technically different digital radiography chest systems have become available for clinical use. Our purpose was to assess the diagnostic performance of eight different digital radiography chest systems for detection of simulated chest disease under clinical conditions. MATERIALS AND METHODS: Assessed were four different flat-panel detector systems, two different charge-coupled device systems, one selenium-coated drum, and one storage phosphor system. For each system, 10 chest images of an anthropomorphic chest phantom were obtained. Each image contained one to 12 simulated chest lesions. Eight radiologists performed soft-copy interpretations. Entrance dose was measured and effective dose calculated. A semi-parametric logistic regression model was used for statistical analysis. RESULTS: Statistically significant differences were found in the diagnostic performance of the eight digital chest systems (p = 0.01). Best performance was observed with the charge-coupled device system with slot-scan technology, yielding a sensitivity of 46% (132 of 288) lesions detected. The performance of three flat-panel detectors and the selenium-drum system was not significantly different from the slot-scan charge-coupled device system. Fewer lesions were detected with the storage phosphor system than with all other digital technologies, with a sensitivity of 34% (99 of 288) lesions detected, slot-scan charge-coupled device system versus storage phosphor system, p < 0.001. The effective dose varied among the digital systems. CONCLUSION: We found differences in diagnostic performance among the eight different digital chest systems. Differences in detection rates are predominantly explained by detector design.

Diagnostic Errors↗

The value of MR angiography techniques in the detection of head and neck paragangliomas.

OBJECTIVE: The objective of this study was to compare three-dimensional phase-contrast angiography (3D PCA), 2D time-of-flight (2D TOF), and 3D TOF magnetic resonance (MR) angiography and a proton density weighted technique in terms of their ability to detect head and neck paragangliomas. MATERIALS AND METHODS: 14 patients with 29 paragangliomas were examined at 1.5 T. Three MR angiography sequences (3D PCA, 2D TOF, and multi-slab 3D TOF) and a proton density (PD) weighted sequence were reviewed by four neuroradiologists. The gold standard was digital subtraction angiography. Presence of tumor was assessed in five grades of confidence. Sensitivity and specificity were calculated after dichotomizing the results. Data was analyzed using the logistic regression method. RESULTS: Mean sensitivity and specificity for the four observers were for PD: 72%/97%, for 3D PCA: 75%/90%, for 2D TOF: 66%/93%, and for 3D TOF: 90%/92%. Sensitivity was significantly better for 3D TOF MRA (P < 0.001). No substantial between-observer variation for tumor detection was present. CONCLUSION: Our results demonstrate that, using 3D TOF MRA, paragangliomas in the head and neck region can be detected with high sensitivity and specificity. Further investigation is necessary to judge the value of 3D TOF MR angiography against fat suppressed contrast enhanced T1 weighted and fat suppressed T2 weighted MR sequences to find the optimal imaging sequence for paragangliomas.

Adult↗

Digital slot-scan charge-coupled device radiography versus AMBER and Bucky screen-film radiography for detection of simulated nodules and interstitial disease in a chest phantom.

PURPOSE: To evaluate the diagnostic performance of full-field slot-scan charge-coupled device (CCD)-based digital radiography in the detection of simulated chest diseases in clinical conditions versus that of two screen-film techniques: advanced multiple beam equalization radiography (AMBER) and Bucky radiography. MATERIALS AND METHODS: Simulated nodules and interstitial nodular and interstitial linear lesions were attached onto an anthropomorphic chest phantom. One hundred sixty-eight lesions were distributed over 25 configurations. A posteroanterior chest radiograph of each configuration was obtained with each technique. The images were presented to six observers. Each lesion was assigned one of two outcome scores: "detected" or "not detected." False-positive readings were evaluated. Differences between the imaging methods were analyzed by using a semiparametric logistic regression model. RESULTS: For simulated nodules and interstitial linear disease, no statistically significant difference was found in diagnostic performance between CCD digital radiography and AMBER. The detection of simulated interstitial nodular disease was better with CCD digital radiography than with AMBER: Sensitivity was 71% (77 of 108 interstitial nodular lesions) with CCD digital radiography but was 56% (60 of 108 lesions) with AMBER (P =.041). Better results for the detection of all lesion types in the mediastinum were observed with CCD digital radiography than with Bucky screen-film radiography: Sensitivity was 45% (227 of 504 total simulated lesions) with CCD digital radiography but was 24% (119 of 504 lesions) with Bucky radiography (P <.001). There were fewer false-positive observations with CCD digital radiography (35 [5.7%] of 609 observations) than with Bucky radiography (47 [9.5%] of 497 observations; P =.012). CONCLUSION: Differences were in favor of the full-field slot-scan CCD digital radiographic technique. This technique provides a digital alternative to AMBER and Bucky screen-film radiography.

Dose-Response Relationship, Radiation↗

Head and neck paragangliomas: improved tumor detection using contrast-enhanced 3D time-of-flight MR angiography as compared with fat-suppressed MR imaging techniques.

BACKGROUND AND PURPOSE: MR imaging techniques have proved their efficacy in imaging the head and neck region. In this study, we compared T1-weighted, dual T2-weighted, and fat-suppressed MR imaging and unenhanced and contrast-enhanced 3D time-of-flight MR angiography sequences for detection of head and neck paragangliomas. METHODS: Thirty-one patients with 70 paragangliomas were examined. Four combinations of MR images were reviewed by two neuroradiologists: T1-weighted and dual T2-weighted fast spin-echo images, T1- and T2-weighted fat-suppressed fast spin-echo images, T1-weighted and contrast-enhanced T1-weighted fat-suppressed spin-echo images, and unenhanced and contrast-enhanced 3D time-of-flight MR angiograms. The randomized examinations were independently evaluated for image quality, presence of tumor, tumor size, and intratumoral flow signal intensity. The standard of reference for presence of tumor was digital subtraction angiography. Data were analyzed by using the logistic regression method. RESULTS: Mean sensitivity, specificity, and negative predictive values, respectively, were assessed by the two observers to be as follows: for dual T2-weighted fast spin-echo, 74%/99%/86%; for T2-weighted fat-suppressed fast spin-echo, 70%/100%/85%; for contrast-enhanced T1-weighted fat-suppressed spin-echo, 73%/100%/86%; and for unenhanced and contrast-enhanced 3D time-of-flight MR angiography, 89%/99%/93%. Sensitivity was significantly better for unenhanced and contrast-enhanced 3D time-of-flight MR angiography (P =.000028). More intratumoral flow signal intensity was depicted with unenhanced and contrast-enhanced 3D time-of-flight MR angiography. CONCLUSION: A combination of unenhanced and contrast-enhanced 3D time-of-flight MR angiography is superior for detecting paragangliomas and should be added to a standard imaging protocol, especially for patients with familial paragangliomas because they are more susceptible to multicentric disease.

Adult↗

The Eurotransplant Study on Twin Lung Transplants (ESOTWIN): 90 paired single-lung transplants from the same donor.

BACKGROUND: Despite its reduced benefit for a single recipient, the transplantation of two single-lung allografts as opposed to one bilateral lung transplant has the indisputable advantage of maximizing the number of patients that benefit from a single donor. METHODS: In the period 1997 to 1999, 90 paired single-lung transplants (SLTx) from 45 donors were performed in 16 lung centers in Eurotransplant, with a complete follow-up of 1 year. RESULTS: No significant differences between left- and right-lung allograft recipients were observed regarding age, sex, primary disease, number of human leukocyte antigen mismatches, cold ischemic time, and donor-to-recipient cytomegalovirus match. Early posttransplant outcome, as assessed by oxygenation index at 12, 24, and 48 hr, also did not differ significantly, and there were no differences in time to extubation and time spent in the intensive care unit. In the first month, six left- and three right-lung allograft recipients died. Bronchiolitis obliterans syndrome developed in 5 of 39 left-lung and 10 of 42 right-lung allograft recipients. If the retrieval team was different from the transplanting team, a significantly worse 1-year posttransplant survival rate was seen in patients who underwent left SLTx compared with those who underwent right SLTx (62% vs. 92%, respectively; P=0.04). CONCLUSIONS: More fatal posttransplant complications occur in patients undergoing left SLTx compared with right SLTx. A less optimistic assessment of the left lung by the not-implanting retrieval team is warranted.

Adolescent↗

Microarrays, pattern recognition and exploratory data analysis.

We explore the application of principal component based approaches to pattern recognition in microarray analysis. A comparative assessment is presented, based on predictive evaluation, following a review of some key methodology. On the basis of these results, we select principal component based linear discrimination for a further in-depth analysis. We are particularly interested in studying the use of principal component decomposition for the evaluation of the condition of estimation of the pooled covariance matrix. The results are used to give some guidance as to how principal components may be used as a data exploratory tool in the analysis of microarray data. Opportunities for further development are outlined as well as implications for wider statistical modelling of microarray data.

Computational Biology↗