Search PubMed⌕ Search

Biomedical subjects

Bart De Spiegeleer

Publications and source records attributed to Bart De Spiegeleer.

5 recordsLinked to original sources

123/125I-labelled 2-iodo-L: -phenylalanine and 2-iodo-D: -phenylalanine: comparative uptake in various tumour types and biodistribution in mice.

PURPOSE: In vitro in the R1M cell model and in vivo in the R1M tumour-bearing athymic model, both [(123)I]-2-iodo-L: -phenylalanine and [(123)I]-2-iodo-D: -phenylalanine have shown promising results as tumour diagnostic agents for SPECT. In order to compare these two amino acid analogues and to examine whether the observed characteristics could be generalised, both isomers were evaluated in various tumour models. METHODS: Transport type characterisation in vitro in A549, A2058, C6, C32, Capan2, EF43fgf4, HT29 and R1M cells with [(123)I]-2-iodo-L: -phenylalanine was performed using the method described by Shotwell et al. Subsequently, [(123)I]-2-iodo-L: -phenylalanine and [(123)I]-2-iodo-D: -phenylalanine tumour uptake and biodistribution were evaluated using dynamic planar imaging and/or dissection in A549, A2058, C6, C32, Capan2, EF43fgf4, HT29 and R1M inoculated athymic mice. Two-compartment blood modelling of the imaging results was performed. RESULTS: In vitro testing demonstrated that [(123)I]-2-iodo-L: -phenylalanine was transported in all tumour cell lines by LAT1. In all tumour models, the two amino acid analogues showed the same general biodistribution characteristics: high and specific tumour uptake and renal tracer clearance. Two-compartment modelling revealed that the D: -isomer showed a faster blood clearance together with a faster distribution to the peripheral compartment in comparison with [(123)I]-2-iodo-L: -phenylalanine. CONCLUSION: [(123)I]-2-iodo-L: -phenylalanine and its D: -isomer are promising tumour diagnostic agents for dynamic planar imaging. They showed a high and similar uptake in all tested tumours. [(123)I]-2-iodo-D: -phenylalanine showed better tracer characteristics concerning radiation dose to other organs.

Animals↗

Comparative biodistribution study of the new tumor tracer [123I]-2-iodo-L-phenylalanine with [123I]-2-iodo-L-tyrosine.

INTRODUCTION: Both A- and l-type amino acid transport are increased in tumor cells relative to normal tissue; these transport systems have been the major focus of the development of amino acid tumor tracers to overcome the limitations of [(18)F]-fluorodeoxyglucose ((18)F-FDG). The newly developed tracer 2-amino-3-(2-[(123)I]iodophenyl)propanoic acid ([(123)I]-2-iodo-l-phenylalanine) showed high and specific tumor uptake, slow renal elimination and low brain uptake. We compared [(123)I]-2-iodo-L-phenylalanine with 2-amino-3-(4-hydroxy-2-[(123)I]iodophenyl)propanoic acid ([(123)I]-2-iodo-L-tyrosine), an L-tyrosine analogue that has recently entered clinical trials. METHODS: [(123)I]-2-iodo-L-phenylalanine and [(123)I]-2-iodo-L-tyrosine were evaluated in rhabdomyosarcoma tumor-bearing athymic mice by means of dynamic planar imaging (DPI) and dissection. A displacement study with L-phenylalanine was performed to prove the specificity of tracer tumor uptake, and kinetic modeling was applied to the DPI results. Moreover, the biodistribution of both tracers was compared with that of (18)F-FDG. RESULTS: Both [(123)I]-2-iodo-L-phenylalanine and [(123)I]-2-iodo-L-tyrosine showed fast, high and specific tumor accumulation with no significant difference. However, [(123)I]-2-iodo-L-phenylalanine was cleared faster from the blood to the bladder in comparison with the tyrosine analogue. Moreover, [(123)I]-2-iodo-L-phenylalanine tumor uptake equilibrated faster with blood. Dissection showed that [(123)I]-2-iodo-L-tyrosine slightly accumulated in the liver, which was not the case for the phenylalanine analogue. In contrast to (18)F-FDG, both tracers showed low uptake in the heart and normal brain tissue, which is advantageous for tumor detection in these organs. CONCLUSIONS: [(123)I]-2-iodo-L-phenylalanine showed more promising characteristics for oncological imaging as compared with [(123)I]-2-iodo-L-tyrosine. The former tracer not only demonstrated faster blood clearance but also showed that the tracer uptake in the tumor reached its equilibrium with the blood pool activity faster, which led to faster and better tumor contrast. Moreover, both tracers could overcome an important limitation of (18)F-FDG-its high normal brain uptake.

Animals↗

Influence of sedation and data acquisition method on tracer uptake in animal models: [123I]-2-iodo-L-phenylalanine in pentobarbital-sedated tumor-bearing athymic mice.

OBJECTIVES: To minimize movement artifacts during tracer imaging studies, the animals are generally sedated. Although many reports describe the effect of barbiturates on brain function, less is published about the general impact on the extracerebral metabolism and tracer biodistribution. This report describes the influence of pentobarbital on tumor uptake of [(123)I]-2-iodo-L-phenylalanine ([(123)I]-2I-L-PA) using dissection and nuclear imaging. METHODS: R1M tumor-bearing athymic mice were divided into two populations: untreated and pentobarbital-treated. Each group was subjected to dynamic and static planar imaging and organ dissection after [(123)I]-2I-L-PA injection. Two-compartment blood modeling was performed. Analysis of variance (ANOVA), t test and clustered boxplot analyses were used to compare the results between the treatment groups and between the data acquisition methods. RESULTS: Two-compartment blood modeling demonstrated that pentobarbital decreased the elimination velocity and the distribution toward the peripheral compartment. Both observations lead to higher blood pool and kidney activities after administering pentobarbital. The dependence of the differential absorption/differential uptake ratio results on the factors organ, method and treatment (3-factor ANOVA) demonstrated that all factors had a significant effect. Moreover, a significant effect for method and treatment was observed for each individual organ, and the ratio of tumor to background showed additionally an ordinal interaction between the latter two factors. Although the tumor uptake values were lower when using sedation and nuclear imaging, the tumor could still be visualized. CONCLUSIONS: An effect of sedation treatment and data acquisition method was demonstrated for 2-iodo-phenylalanine, currently under development as tumor tracer. It is recommended that animal experiments should include quantitative investigation of sedation and the data acquisition method.

Animals↗

In vivo evaluation and dosimetry of 123I-2-iodo-D-phenylalanine, a new potential tumor-specific tracer for SPECT, in an R1M rhabdomyosarcoma athymic mouse model.

UNLABELLED: Earlier reports described the preferential uptake of d-amino acids in tumor-bearing mice. Moreover, it was shown that in tumor cells in vitro the L-amino acid transporter system seemed to lack stereospecificity. Because of the successful results with 123/125I-2-iodo-L-phenylalanine, 123/125I-2-iodo-D-phenylalanine was developed, and its tumor-detecting characteristics were evaluated in vivo. METHODS: 123I labeling of 2-iodo-D-phenylalanine was performed with a kit formulation by use of Cu1+-assisted nucleophilic exchange. 123I-2-Iodo-D-phenylalanine was evaluated in R1M tumor-bearing athymic mice by dynamic planar imaging (DPI) and dissection. The in vivo stability of the tracer was tested by high-performance liquid chromatography. Tumor tracer retention and tracer contrast were evaluated as a function of time. Two-compartment blood modeling from DPI results and dosimetric calculations from biodistribution results were carried out. Moreover, 125I-2-iodo-D-phenylalanine and 18F-FDG uptake in acute inflammation was investigated. RESULTS: 123I-2-Iodo-D-phenylalanine was metabolically stable. Fast, high, and specific tumor retention was observed. Two-compartment modeling confirmed the fast clearance of the tracer through the kidneys to the bladder, as observed by DPI and dissection. Moreover, compared with the L-isomer, 123I-2-iodo-D-phenylalanine demonstrated faster clearance and faster uptake in the peripheral compartment. No accumulation in the abdomen or in the brain was noted. Dosimetry revealed that 123I-2-iodo-D-phenylalanine demonstrated a low radiation burden comparable to those of 123I-2-iodo-L-phenylalanine and 123I-2-iodo-L-tyrosine. Although 123I-2-iodo-D-phenylalanine showed a tumor retention of only 4%, the tumor contrast was increased up to 350% at 19 h after injection. CONCLUSION: 123I-2-Iodo-D-phenylalanine is a promising tracer for diagnostic oncologic imaging because of its high, fast, and specific tumor uptake and fast clearance from blood.

Animals↗

Statistical analysis of tablet breakability methods.

PURPOSE: Using a model tablet, the influence of breakability methodology on mass uniformity of half- and quarter-tablets as well as the comparison of different data acquisition and evaluation approaches were investigated. Moreover, different breakability evaluation criteria were compared based upon distribution as well as distribution-free models. METHODS: A cross-scored tablet, i.e. having two break-marks, was broken by different methods by different persons, and the masses determined for the whole (unbroken) tablets, the half-tablets and quarter-tablets. RESULTS: Beside the possible interaction between the methodology and the person breaking the tablets, the major factor significantly influencing the mass uniformity of broken tablets is the breakability methodology. The best results, i.e. smallest loss and smallest variability, are obtained when the breaking force applied by the thumbs is directed towards the score side of the tablet, i.e. by "opening" the score. Using our model tablet, significant differences between the different evaluation criteria are observed, with the USP/NF approach being best in line with the detailed analysis of all broken tablets. CONCLUSIONS: Assuming that for this model tablet the variance is a linear function of the break-line length, the standard deviation of quarter-tablets is theoretically calculated to be 0.87 times the standard deviation of the half-tablets. As the absolute standard deviation, expressed in mass units, will thus remain approximately identical, the relative standard deviation will nearly double as the mean mass of the quarter-tablets will be half of the mean mass of the half-tablets. This was experimentally confirmed.

Analysis of Variance↗