Search PubMed⌕ Search

Biomedical subjects

Barry B Goldberg

Publications and source records attributed to Barry B Goldberg.

24 records · Page 2Linked to original sources

[Three dimensional ultrasound volumetric assessment of the synovial fluid in the ankle and hindfoot: Technique and normative data].

PURPOSE: Since synovial fluid is an important marker of disease, we performed three-dimensional ultrasound volumetric measurements of synovial fluid to provide baseline normative data. MATERIALS AND METHODS: Volume data were acquired using a 7-10 MHz three dimensional ultrasound probe on 40 ankles in 20 volunteers (25-61 years). Amounts of fluid were assessed in the ankle joint recesses, bursae and tendon sheaths. Images were acquired in the sagittal plane and were reconstructed in three orthogonal planes; transverse, sagittal and coronal. Fluid volumes were calculated from the volume data set using the manual planimetric method. RESULTS: Fluid in tendon sheaths was most common about the peroneals, and unlike prior MRI results, was less common around the flexors. In the flexors, fluid was most common around the flexor hallucis longus tendon, less common around posterior tibial tendon, and rare around fleksor digitorum longus tendon. In the extensors, fluid was less common but, when present, of greater volume, especially around the extensor hallucis longus tendon. Fluid was most common around the anterior tibial tendon and rare around the extensor digitorum longus tendon. Sparse fluid was seen in the majority of retrocalcaneal bursae. Fluid in the anterior ankle recess was quite common. Visualization of fluid in the posterior ankle recess was infrequent. CONCLUSION: Three-dimensional ultrasound permits measurement of fluid volume in the normal ankle/hindfoot; normative data are provided.

Adult↗

Hepatic tumor detection: MR imaging and conventional US versus pulse-inversion harmonic US of NC100100 during its reticuloendothelial system-specific phase.

PURPOSE: To compare conventional ultrasonography (US) and magnetic resonance (MR) imaging with contrast agent-enhanced US for detection of VX-2 liver tumors in rabbits. MATERIALS AND METHODS: Conventional gray-scale liver US was performed in 65 rabbits, 38 of which had VX-2 hepatic tumor implants. Twenty minutes after contrast agent injection, gray-scale pulse-inversion harmonic US images of the liver-specific phase were obtained. Following sacrifice of the animals, T1- and T2-weighted MR imaging was performed at 4-mm intervals. Pathologic analysis was performed as the reference standard. The capability of each imaging modality to correctly depict tumor presence or absence and the number of tumors was compared. RESULTS: Conventional US correctly depicted the presence or absence of tumors in 54 rabbits, for an accuracy of 83%, sensitivity of 71%, and specificity of 100%. With contrast-enhanced US, accuracy increased to 92% (60 correct cases); sensitivity, to 87%; and specificity, to 100%. MR imaging facilitated 56 correct diagnoses, for an accuracy of 86%, sensitivity of 82%, and specificity of 93%. There was a marginally significant difference between US with and US without contrast agent (P =.07) but not between MR imaging and contrast-enhanced US (P > or = .34). When the numbers of correctly detected tumors were compared, contrast-enhanced US performed significantly better than MR imaging (P =.02) and conventional US (P =.04). CONCLUSION: There was no significant difference between contrast-enhanced US and MR imaging in the detection of hepatic tumors, whereas contrast-enhanced US had the highest accuracy (92%) of the three modalities studied.

Animals↗

Contrast-enhanced two- and three-dimensional sonography for evaluation of intra-abdominal hemorrhage.

OBJECTIVE: To determine whether a contrast agent enhances sonographic detection of bleeding sites in the abdomen and whether contrast-enhanced three-dimensional sonography provides additional information compared with contrast-enhanced two-dimensional sonography. METHODS: Bleeding sites were created within the livers (n = 3), spleens (n = 5), and kidneys (n = 3) of 3 dogs. A sonographic contrast agent with vascular and parenchymal enhancement capabilities was administered intravenously at a dose of 0.02 mL/kg. Before and after each contrast agent injection, the bleeding sites were imaged with two- and three-dimensional sonography in gray scale harmonic imaging and color flow modes. Sonographic findings were compared with gross pathologic findings. RESULTS: Noncontrast-enhanced sonography was not able to show the specific location of the active bleeding in any of the organs evaluated. The contrast agent enhanced the sonographic detection of blood flow in normal vessels and extravasated blood from damaged vessels or organs in all cases. Intrasplenic and intrahepatic hematomas were better identified on delayed imaging sequences because there was marked enhancement of the normal parenchyma, whereas the hematomas remained unenhanced. Reconstructed three-dimensional sonography showed spatial relationships of the bleeding sites and surrounding structures. Gross pathologic findings were consistent with the contrast-enhanced sonographic results. CONCLUSIONS: Contrast-enhanced sonography improves the detection and evaluation of abdominal bleeding sites. Contrast-enhanced three-dimensional sonography appears to provide additional information when compared with two-dimensional sonography.

Animals↗

Endoluminal sonography of the genitourinary and gastrointestinal tracts.

OBJECTIVE: Endoluminal sonography with high-frequency catheter-based transducers is a technique well suited to imaging structures beyond the lumen of the hollow viscus. The purpose of this article was to review some aspects of endoluminal sonography, including instrumentation, clinical applications in the gastrointestinal and genitourinary tracts, and its three-dimensional reconstruction. METHODS: The development of 6F to 10F catheter-based ultrasonic probes has made this technique available for use within a variety of lumina. Endoluminal sonography with frequencies of 9 to 20 MHz has been used for evaluation of a wide range of abnormalities in both the genitourinary and gastrointestinal tracts. RESULTS: Uses in the gastrointestinal tract include quantification of esophageal varices, distinguishing between various submucosal lesions, and measuring the degree of fibrosis in scleroderma. In the genitourinary system, endoluminal sonography has been used to guide collagen injection, to diagnose urethral diverticula and upper tract neoplasms, to locate crossing vessels and septa for guiding endopyelotomy, and to identify submucosal calculi. CONCLUSIONS: High-resolution endoluminal sonography is a new sonographic approach for evaluation of the genitourinary and gastrointestinal tracts. This should lead to the expansion of the diagnostic capabilities of sonography, providing important information for decision making relative to patient care and minimally invasive interventional procedures. Reconstructed three-dimensional endoluminal sonography has the potential to become a valuable tool in both the research and clinical areas.

Digestive System↗

Contrast-enhanced transrectal ultrasonography of a novel canine prostate cancer model.

OBJECTIVE: This study evaluated the utility of a new animal model for prostate cancer imaging using a new ultrasonographic contrast agent (Sonazoid [NC100100]; Amersham Health, Oslo, Norway), for prostate cancer detection. METHODS: Twenty-four dogs had a canine transmissible venereal sarcoma cell line injected (50 million cells/mL) directly into the prostate, producing a neoplasm in 15 to 40 days. Transrectal ultrasonography was performed in power Doppler mode on 8 dogs (phase I) and in gray scale phase inversion harmonic imaging mode on 16 animals (including control animals without tumors; phase II). Evaluations were repeated after intravenous injections of the contrast agent (dose, 0.00625-0.20 microL/kg). Histopathologic examination was performed after each study. For the phase II experiments, sensitivity, specificity, and accuracy were calculated. RESULTS: The contrast agent improved visualization of the prostate cancer vascularity and delineation of tumor size and shape in both power Doppler and phase inversion harmonic imaging modes. Canine transmissible venereal sarcoma tumors ranging from 3 x 5 to 40 x 50 mm were detected. The accuracy for detecting the number of prostate tumors increased (in phase II) from 67% to 87% with the addition of the contrast agent. Histopathologic examination confirmed the ultrasonographic findings and revealed typical canine transmissible venereal sarcoma cells infiltrating the prostate with moderate neovascularity. CONCLUSIONS: The novel canine tumor model was useful for evaluating ultrasonographic prostate imaging techniques. Improved detection of prostate tumors in dogs was possible with gray scale phase inversion harmonic imaging of the contrast agent. The accuracy of lesion detection increased from 67% to 87%.

Animals↗