Search PubMed⌕ Search

Biomedical subjects

Barbara Frank

Publications and source records attributed to Barbara Frank.

5 recordsLinked to original sources

Regulation of human retinal blood flow by endothelin-1.

There is evidence from in vitro and animal studies that endothelin is a major regulator of retinal blood flow. We set out to characterize the role of the endothelin-system in the blood flow control of the human retina. Two studies in healthy subjects were performed. The study design was randomized, placebo-controlled, double-masked, balanced, two-way crossover in protocol A and three way-way crossover in protocol B. In protocol A 18 healthy male subjects received intravenous endothelin-1 (ET-1) in a dose of 2.5 ng kg (-1)min(-1) for 30 min or placebo on two different study days and retinal vessel diameters were measured. In protocol B 12 healthy male subjects received ET-1 in stepwise increasing doses of 0, 1.25, 2.5 and 5 ng kg (-1)min(-1) (each infusion step over 20 min) in co-infusion with the specific ET(A)-receptor antagonist BQ123 (60 microg min (-1)) or placebo or BQ123 alone investigating retinal vessel diameters, retinal blood velocity and retinal blood flow. Measurements of retinal vessel size were done with the Zeiss retinal vessel analyzer. Measurements of blood velocities were done with bi-directional laser Doppler velocimetry. From these measurements retinal blood flow was calculated. In protocol A exogenous ET-1 tended to decrease retinal arterial diameter, but this effect was not significant versus placebo. No effect on retinal venous diameter was seen. In protocol B retinal venous blood velocity and retinal blood flow was significantly reduced after administration of exogenous ET-1. These effects were significantly blunted when BQ-123 was co-administered. By contrast, BQ-123 alone had no effect on retinal hemodynamic parameters. Concluding, BQ123 antagonizes the effects of exogenously administered ET-1 on retinal blood flow in healthy subjects. In addition, the results of the present study are compatible with the hypothesis that ET-1 exerts its vasoconstrictor effects in the retina mainly on the microvessels.

Adult↗

Propranolol and atropine do not alter choroidal blood flow regulation during isometric exercise in healthy humans.

Recent studies indicate that the human choroid has a considerable capacity to keep blood flow constant despite exercise-induced increases in perfusion pressure. The mechanisms underlying this vasoconstrictor response remain unclear. We hypothesized that pharmacological modulation of the autonomic nervous system may alter the choroidal pressure/flow relationship during squatting. To test this hypothesis, we performed a randomized, double-masked, placebo-controlled, three-way crossover study in 15 healthy male volunteers. Subjects received, on different study days, intravenous infusions of the beta-adrenoceptor antagonist propranolol, the muscarinic receptor antagonist atropine, or placebo. During these infusions, subjects performed squatting for 6 min. Choroidal blood flow was assessed with laser Doppler flowmetry and ocular perfusion pressure (OPP) was calculated from mean arterial pressure and intraocular pressure. As expected, propranolol reduced basal pulse rate, whereas atropine increased pulse rate, indicating that the drugs were administered at systemically effective doses. None of the drugs altered the choroidal pressure/flow relationship during isometric exercise. These data indicate that the regulatory vasoconstrictor capacity of the choroid during exercise is not affected by systemic blockade of beta-adrenoceptors or muscarinic receptors.

Adrenergic beta-Antagonists↗

Calculation of the diameter of the central retinal artery from noninvasive measurements in humans.

PURPOSE: The aim of the present study was to calculate the diameter of the central retinal artery from results as obtained with non-invasive techniques in healthy young subjects. METHODS: Twenty-four healthy male subjects participated in this study. Total retinal blood flow was calculated from combined bi-directional laser Doppler velocimetry and measurement of retinal venous diameters using the Zeiss retinal vessel analyzer. Using these techniques red blood cell velocity and vessel diameters of all visible veins entering the optic nerve head were measured and total retinal blood flow was calculated. Blood flow velocity in the central retinal artery was measured with color Doppler imaging. Form these outcome parameters the diameter of the central retinal artery was calculated for each subject individually. RESULTS: In the present study cohort the mean retinal blood flow was 38.1 +/- 9.1 microl/min and the mean flow velocity in the central retinal artery was 6.3 +/- 1.2 cm/s. From these data we calculated a mean diameter of the central retinal artery of 163 +/- 17 microm. CONCLUSIONS: Our results are in good agreement with data obtained from in vitro studies. The data of the present study also indicate that one needs to be careful to interpret velocity data from the central retinal artery in terms of retinal blood flow.

Adult↗