Search PubMed⌕ Search

Biomedical subjects

Baohong Liu

Publications and source records attributed to Baohong Liu.

24 records · Page 2Linked to original sources

Covalently coupling the antibody on an amine-self-assembled gold surface to probe hyaluronan-binding protein with capacitance measurement.

Hyaluronan-binding proteins (HABPs), the important structural components of extracellular matrices, served important structural and regulatory functions during development and in maintaining adult tissue homestats. A sensitive, specific and rapid-responsing immunosensor to probe hyaluronan-binding cartilage protein was presented in this work. The novel immunosensor supplied a label-free detection method for HABP, which was based on measuring the capacitance change in-between the unlabeled HABP (antigen) and rabbit-anti-HABP (Ra-HABP, antibody). The HABP immunosensor was prepared by covalently coupling Ra-HABP on an amine-self-assembled gold surface with glutaraldehyde. The capacitance change corresponding to the concentration of HABP, the target antigen, was evaluated by an electrochemical approach called potentiostatic-step in microseconds. The immunosensor showed a specific response to HABP in the range 10-1000 ng/ml. The presented work supplied a promising clinical screening method.

Adsorption↗

TiO2 sol-gel derived amperometric biosensor for H2O2 on the electropolymerized phenazine methosulfate modified electrode.

A novel hydrogen peroxide biosensor was developed based on the immobilization of horseradish peroxidase (HRP) in a TiO(2) sol-gel matrix on an electropolymerized phenazine methosulfate (PMS) modified electrode surface. Such membranes are of interest due to their high surface area, biological compatibility, and ease of fabrication. HRP entrapped in the TiO(2) matix was stable and retained its activity to a large extent. Cyclic voltammetry and amperometric measurements were employed to demonstrate the feasibility of electron transfer between immobilized HRP and the glassy carbon electrode via electropolymerized PMS. The influence of various experimental parameters such as operating potential, pH, temperature, and stability was investigated for optimum analytical performance. The biosensor provided a wide linear calibration range from 4.0x10(-6) M to 1.0x10(-3) M, with a detection limit of 8.0x10(-7) M at a signal-to-noise ratio of 3. The sensor retained 80% of its original activity after two months of operation.

Biosensing Techniques↗

A BOD biosensor based on a microorganism immobilized on an Al2O3 sol-gel matrix.

A novel BOD biosensor has been fabricated from a microbial membrane on an oxygen electrode; a porous inorganic Al2O3 sol-gel matrix was used to immobilize the yeast. Use of the sensor is convenient and rapid compared with the official BOD5 method. The gelation time required to form the microorganism membrane was less than 15 min. There was linear relationship between the response (sensor current) and BOD values ranging from 10-50 mg x L(-1). The lifetime of the BOD biosensor was more than 30 days at ambient temperature.

Aluminum Oxide↗

Differentiating the orientations of photosynthetic reaction centers on Au electrodes linked by different bifunctional reagents.

The photosynthetic reaction center (RC) composite film was fabricated by self-assembled monolayers (SAMs) on the Au electrode with two different bifunctional reagents, 4-aminothiophenol (ATP) and 2-mercaptoethylamine (MEA), respectively. The square wave voltametry (SWV), bulk electrolysis and photocurrent test were employed for characterizing the composite film. The dramatic different electrochemical characteristics were observed for the two types of films, which strongly suggested an orientational difference for RC arising from the structural difference between the two bifunctional reagents. For RC-MEA film, three redox peaks which implying electron transfer (ET) between the primary donor (P) and the bacteriopheophytin (Bphe) were observed. While for RC-ATP film, two redox peaks implying ET between the nonheme iron and the primary quinone (Q(A)) were observed. The ET behavior driven by electric field also supported the result that the RC could be linked to the electrode at different sites. The site-specific immobilization approach reported here supplies a method to differentiate the protein orientation.

Aniline Compounds↗

Titania and alumina sol-gel-derived microfluidics enzymatic-reactors for peptide mapping: design, characterization, and performance.

The design and characterization of titania-based and alumina-based Poly(dimethylsiloxane) (PDMS) microfluidics enzymatic-reactors along with their analytical features in coupling with MALDI-TOF and ESI-MS were reported. Microfluidics with microchannel and stainless steel tubing (SST) were fabricated using PDMS casting and O(2)-plasma techniques, and were used for the preparation of an enzymatic-reactor. Plasma oxidation for the PDMS microfluidic system enabled the channel wall of the microfluidics to present a layer of silanol (SiOH) groups. These SiOH groups act as anchors onto the microchannel wall linked covalently with the hydroxyl groups of trypsin-encapsulated sol matrix. As a result, the trypsin-encapsulated gel matrix was anchored onto the wall of the microchannel, and the leakage of gel matrix from the microchannel was effectively prevented. A feature of the microfluidic enzymatic-reactors is the feasibility of performing on-line protein analysis by attached SST electrode and replaceable tip. The success of trypsin encapsulation was investigated by AFM imaging, assay of enzymatic activity, CE detection, and MALDI-TOF and ESI-MS analysis. The lab-made devices provide an excellent extent of digestion even at a fast flow rate of 7.0 microL/min, which affords the very short residence time of ca. 2 s. With the present device, the digestion time was significantly shortened compared to conventional tryptic reaction schemes. In addition, the encapsulated trypsin exhibits increased stability even after continuous use. These features are required for high-throughput protein identification.

Aluminum Oxide↗

Strategy for allosteric analysis based on protein-patterned stationary phase in microfluidic chip.

An effective method is presented for the on-chip analysis of chiral interactions with a successful depression of nonspecific adsorption. The alumina gel-derived protein network on poly(methyl methacrylate) (PMMA) microchannel was explored to form a protein-stationary phase and then used to carry out electrophoresis for fast enantioseparation coupled with electrochemical detection. On the basis of the chemical modification of a synthesized copolymer containing silane-functionalized scaffold, alumina sol-gel could react readily with the silane groups and form steady microstructure on the chip surface achieving the encapsulation of functional biomolecules. Compared with the native PMMA microchannels, the modified surfaces exhibited much better wettability, more stable and enhanced electroosmotic mobility, and less nonspecific adsorption. The water contact angle and EOF of alumina-gel-derived PMMA substrate were 22 degrees and 4.3 x 10(-4) cm(2) V(-1) s(-1), compared to those of 73 degrees and 1.9 x 10(-4) cm(2) V(-1) s(-1) from the untreated one, respectively. Bovine serum albumin, acting as a target protein, could be stably and homogeneously immobilized in the modified PMMA microchannel to fabricate a protein-stationary phase. Under a mild condition, D- and L-tryptophan were efficiently separated with a resolution of 1.57. The as-prepared microchip can perform chiral separations within short time, indicating that the general protocol has the potential to provide a platform for high throughput screening of enantiomer candidates such as those biochemical drugs with protein targets and the research of receptor interactions.

Adsorption↗