Search PubMed⌕ Search

Biomedical subjects

Badrinath Roysam

Publications and source records attributed to Badrinath Roysam.

21 records · Page 2Linked to original sources

The dual-bootstrap iterative closest point algorithm with application to retinal image registration.

Motivated by the problem of retinal image registration, this paper introduces and analyzes a new registration algorithm called Dual-Bootstrap Iterative Closest Point (Dual-Bootstrap ICP). The approach is to start from one or more initial, low-order estimates that are only accurate in small image regions, called bootstrap regions. In each bootstrap region, the algorithm iteratively: 1) refines the transformation estimate using constraints only from within the bootstrap region; 2) expands the bootstrap region; and 3) tests to see if a higher order transformation model can be used, stopping when the region expands to cover the overlap between images. Steps 1): and 3), the bootstrap steps, are governed by the covariance matrix of the estimated transformation. Estimation refinement [Step 2)] uses a novel robust version of the ICP algorithm. In registering retinal image pairs, Dual-Bootstrap ICP is initialized by automatically matching individual vascular landmarks, and it aligns images based on detected blood vessel centerlines. The resulting quadratic transformations are accurate to less than a pixel. On tests involving approximately 6000 image pairs, it successfully registered 99.5% of the pairs containing at least one common landmark, and 100% of the pairs containing at least one common landmark and at least 35% image overlap.

Algorithms↗

Rapid automated three-dimensional tracing of neurons from confocal image stacks.

Algorithms are presented for fully automatic three-dimensional (3-D) tracing of neurons that are imaged by fluorescence confocal microscopy. Unlike previous voxel-based skeletonization methods, the present approach works by recursively following the neuronal topology, using a set of 4 x N2 directional kernels (e.g., N = 32), guided by a generalized 3-D cylinder model. This method extends our prior work on exploratory tracing of retinal vasculature to 3-D space. Since the centerlines are of primary interest, the 3-D extension can be accomplished by four rather than six sets of kernels. Additional modifications, such as dynamic adaptation of the correlation kernels, and adaptive step size estimation, were introduced for achieving robustness to photon noise, varying contrast, and apparent discontinuity and/or hollowness of structures. The end product is a labeling of all somas present, graph-theoretic representations of all dendritic/axonal structures, and image statistics such as soma volume and centroid, soma interconnectivity, the longest branch, and lengths of all graph branches originating from a soma. This method is able to work directly with unprocessed confocal images, without expensive deconvolution or other preprocessing. It is much faster that skeletonization, typically consuming less than a minute to trace a 70-MB image on a 500-MHz computer. These properties make it attractive for large-scale automated tissue studies that require rapid on-line image analysis, such as high-throughput neurobiology/angiogenesis assays, and initiatives such as the Human Brain Project.

Algorithms↗

Algorithms for automated oximetry along the retinal vascular tree from dual-wavelength fundus images.

We present an automated method to perform accurate, rapid, and objective measurement of the blood oxygen saturation over each segment of the retinal vascular hierarchy from dual-wavelength fundus images. Its speed and automation (2 s per entire image versus 20 s per segment for manual methods) enables detailed level-by-level measurements over wider areas. An automated tracing algorithm is used to estimate vessel centerlines, thickness, directions, and locations of landmarks such as bifurcations and crossover points. The hierarchical structure of the vascular network is recovered from the trace fragments and landmarks by a novel algorithm. Optical densities (OD) are measured from vascular segments using the minimum reflected intensities inside and outside the vessel. The OD ratio (ODR=OD600/OD570) bears an inverse relationship to systemic HbO2 saturation (SO2). The sensitivity for detecting saturation change when breathing air versus pure oxygen was calculated from the measurements made on six subjects and was found to be 0.0226 ODR units, which is in good agreement with previous manual measurements by the dual-wavelength technique, indicating the validity of the automation. A fully automated system for retinal vessel oximetry would prove useful to achieve early assessments of risk for progression of disease conditions associated with oxygen utilization.

Algorithms↗