Search PubMed⌕ Search

Biomedical subjects

B Zwissler

Publications and source records attributed to B Zwissler.

At least 55 records · Page 3Linked to original sources

Biochemical and cellular composition of alveolar epithelial lining fluid in anesthetized healthy lambs.

Pulmonary toxicity of inhaled materials is often evaluated by (repetitive) assessment of the composition of bronchoalveolar lavage (BAL) fluid or of epithelial lining fluid (ELF) in sheep and lambs. Knowledge of the typical constituents of these fluids obtained from healthy animals is essential for identification of pathologic changes. Few studies have dealt with normal constituents of BAL fluid or ELF in sheep and lamb. The comparability of these studies, however, is limited for reasons concerning the choice of model and BAL technique. The biochemical and cellular composition of alveolar ELF obtained by a standardized BAL procedure was examined in 15 pento-barbital anesthetized 4 months old Merino lambs unexposed to inhaled substances. ELF volume was calculated by using the urea dilution method. We found 20.3 x 10(5) leucocytes per ml ELF, 87.5% of which were alveolar macrophages. Basophils and neutrophils were practically absent while 5% of the counted cells were lymphocytes. 76% of recovered cells were viable. The ELF contained 7 mg/ml total protein; enzyme activities of LDH and AP were 1692 U/l and 145 U/l, respectively.

Anesthesia, Inhalation↗

[Anesthesia procedures--postoperative effects].

The perioperative morbidity and mortality is mainly influenced by the type and duration of surgery as well as the patient's preoperative state of health. Anesthesia per se, however, may also result in severe perioperative (patho) physiological changes, which may be both desired (e.g. analgesia, vasodilation in vascular surgery) or detrimental (e.g. hypothermia, ventilatory depression) and which may differ depending on the anesthetic technique used (e.g. general anesthesia vs. regional anesthesia). Yet, all anaesthetic techniques have in common, that their effects are not limited to the duration of the surgical intervention, but may expand far into the postoperative period. Therefore, many trials have been performed in the past aiming to compare the impact of different anesthetic techniques on the incidence of postoperative techniques, no significant advantage of one or the other technique has been identified up to now with respect to postoperative mortality or severe morbidity. This finding may be due to at least three factors. 1) Many side-effects related to anesthesia--due to close postoperative monitoring--are detected and treated early in the postoperative phase (e.g. in the recovery room), thereby preventing serious complications.2) Postoperative mortality related exclusively to anesthesia probably is so low, that huge patient numbers would be required to demonstrate any significant differences between different techniques. 3) Besides the factor 'anesthesia', many other factors contribute to the anesthesia related morbidity and mortality (e.g. the factor 'anesthetist') which are hardly quantified. The fact that clear advantages for a single technique have not yet been demonstrated must not, however, result in anesthetic 'nihilism'. Rather there may be good reasons in the individual patient (e.g. lack of a recovery room), to prefer a certain anesthetic technique or drug over another, in order to lower the individual risk of anesthesia. Whether the use of a certain technique-e.g. spinal or epidural anesthesia-may contribute to a reduction of specific postoperative surgical complications (e.g. rate of reocclusion subsequent to peripheral vascular surgery) is presently under investigation.

Anesthesia↗

[Small-volume resuscitation for hypovolemic shock. Concept, experimental and clinical results].

The concept of small-volume resuscitation, the rapid infusion of a small volume (4 ml/kg BW) of hyperosmolar 7.2-7.5% saline solution for the initial therapy of severe hypovolemia and shock was advocated more than a decade ago. Numerous publications have established that hyperosmolar saline solution can restore arterial blood pressure, cardiac index and oxygen delivery as well as organ perfusion to pre-shock values. Most prehospital studies failed to yield conclusive results with respect to a reduction in overall mortality. A meta-analysis of preclinical studies from North and South America, however, has indicated an increase in survival rate by 5.1% following small-volume resuscitation when compared to standard of care. Moreover, small-volume resuscitation appears to be of specific impact in patients suffering from head injuries with increased ICP and in severest trauma requiring immediate surgical intervention. Results from clinical trials in Austria, Germany and France have demonstrated positive effects of hyperosmolar saline solutions when used for fluid loading or fluid substitution in cardiac bypass and in aortic aneurysm surgery, respectively. A less positive perioperative fluid balance, a better hemodynamic stability and improved pulmonary function were reported. In septic patients oxygen consumption could significantly be augmented. The most important mechanism of action of small-volume resuscitation is the mobilisation of endogenous fluid primarily from oedematous endothelial cells, by which the rectification of shock-narrowed capillaries and the restoration of nutritional blood, flow is efficiently promoted. Moreover, after ischemia reperfusion a reduction in sticking and rolling leukocytes have been found following hyperosmolar saline infusion. Both may be of paramount importance in the long-term preservation of organ function following hypovolemic shock. An increased myocardial contractility in addition to the fluid loading effects of hyperosmolar saline solutions has been suggested as a mechanism of action. This, however, could not be confirmed by pre-load independent measures of myocardial contractility. Some concerns have been raised regarding the use of hyperosmolar saline solutions in patients with a reduced cardiac reserve. A slower speed of infusion and adequate monitoring is recommended for high risk patients. Recently, hyperosmolar saline solutions in combination with artificial oxygen carriers have been proposed to increase tissue oxygen delivery through enhanced O2 content. This interesting perspective, however, requires further studies to confirm the potential indications for such solutions. Many hyperosmolar saline colloid solutions have been investigated in the past years, from which 7.2-7.5% sodium chloride in combination with either 6-10% dextran 60/70 or 6-10% hydroxyethyl starch 200,000 appear to yield the best benefit-risk ratio. This has led to the registration of the solutions in South America, Austria, The Czech Republic, and is soon awaited for North America.

Dextrans↗

Effect of hypertonic saline/dextran on post-stenotic myocardial perfusion, metabolism, and function during resuscitation from hemorrhagic shock in anesthetized pigs.

Resuscitation using small volumes of hypertonic saline solutions normalizes cardiac output without fully restoring arterial pressure. This study compared the efficacy of either 7.2% saline/10% dextran 60 (HSDex) or the identical sodium load of normal saline (NS) to improve regional myocardial blood flow (MBF), contractile function, and oxygen metabolism in the presence of a critical coronary stenosis. Fourteen anesthetized, open-chest pigs (25 +/- 3.6 kg) were instrumented to assess left anterior descending coronary artery (LAD) flow, post-stenotic oxygen, and lactate metabolism, regional myocardial segment shortening (SS, sonomicrometry), and MBF (radioactive microspheres). After implementation of a critical LAD-stenosis, shock was induced by hemorrhage (mean arterial pressure (MAP) 45-50 mmHg for 75 min). Resuscitation was started by infusion (2 min) of either HSDex (n = 7,10% of blood loss) or NS (n = 7, 80% of blood loss); 30 min later 6% dextran 60 (10% of blood loss) was administered in both groups. The LAD-stenosis did not affect myocardial metabolism, SS, or MBF at rest. After hemorrhage, MBF remained unchanged from baseline in non-stenotic but decreased by 53% in post-stenotic myocardium (p < .05). The endo-epicardial flow ratio fell below 1.0 in both areas. SS decreased by 10-15% only in post-stenotic myocardium (p < .05). Resuscitation with both HSDex and NS restored cardiac index (CI) but not MAP. MBF increased above baseline values with either solution in non-stenotic while it remained at shock levels in post-stenotic myocardium, where ischemia persisted as evidenced by lactate production and depressed SS. Neither in non-stenotic nor in post-stenotic myocardium was the epi-endocardial flow ratio normalized upon resuscitation with HSDex or NS. We conclude that in the presence of a flow-limiting coronary stenosis, initial fluid resuscitation with both HSDex and the identical sodium load of NS failed to restore perfusion pressure, redistributed MBF in favor of normally perfused myocardium, and did not reverse ischemia in post-stenotic myocardium.

Animals↗

Aerosol production and aerosol droplet size distribution during mechanical ventilation (IPPV) with a new ultrasonic nebulizer.

Administration of drugs via the airway is increasingly practiced in ICU- and surgical patients. For this purpose, aerosols may be produced by either jet nebulization or ultrasonic droplet generation. In mechanically ventilated patients, aerosol delivery is often insufficient. The influence of the ventilatory pattern on nebulizer efficacy is poorly understood. In the present in vitro study we determined the efficacy of a new ultrasonic nebulizer in delivering aerosolized epoprostenol using defined ventilator settings. We determined aerosol delivery rates, the aerosol droplet size distribution and the impact of the connection tubing on drug delivery, applying adult and infant ventilation patterns. Aerosol production rates ranged from 0.28 to 0.57 ml per minute. Using an adult ventilator setting volume controlled ventilation (CMV) led to a higher aerosol production rate than pressure controlled ventilation (PCV) at identical tidal volumes and mean airway pressures (0.57 ml/min,CMV vs 0.39 ml/min, PCV). With an infant ventilator setting, nebulizer rates were lower than those found for the adult ventilator setting, but did not differ substantially between CMV and PCV mode (0.29 ml/min, CMV vs 0.28 ml/min, PCV). Aerosol delivery rates distal to the endotracheal tube changed according to aerosol production rates (adult mode: 0.18 ml/min, CMV vs 0.10 ml/min, PCV; infant mode: 0.03 ml/min, both CMV and PCV). In the infant ventilation mode, a higher percentage of the aerosol was trapped in the catheter mount as compared to the adult ventilation mode. Mass median droplet diameters for each of the four ventilator settings were almost identical (4.63 to 5.09 micron) and smaller than indicated in the product specifications (8 micron). Delivery rates and sizes of droplets delivered by the new ultrasonic nebulizer SUN 345(R) agree well with previously reported data from comparable settings using diverse nebulizer devices.

Adult↗

Eight hours' inhalation of prostacyclin (PGI2) in healthy lambs: effects on tracheal, bronchial, and alveolar morphology.

OBJECTIVE: To study potential toxic effects of long-term (8 h) inhaled prostacyclin (PGI2) on respiratory tract tissues. DESIGN: In a prospective, randomized order, either PGI2 (n =7) or normal saline (n = 7) was aerosolized during a time period of 8 h in healthy lambs. SETTING: Institute for Surgical Research of the Ludwig-Maximilians University of Munich. ANIMALS: 14 health, anesthetized, ventilated lambs. INTERVENTIONS: All animals were endotracheally intubated followed by tracheotomy. PGI2 solution or normal saline was administered with a jet nebulizer (delivery rate 4-10 ml/h; mass median diameter of aerosol particles 3.1 microns). MEASUREMENTS AND RESULTS: Histomorphological changes after 8-h inhalation of PGI2 solution were compared to those after 8-h inhalation of normal saline. Tracheal and bronchoalveolar tissues were examined by light and electron microscopy in order to assess tissue damage induced by inhaled PGI2. Pathological changes were ranked by a blinded observer following a graduation system ranging from "absence of pathological changes" to "maximal pathological changes". Abnormalities were restricted to the trachea (focal flattening of the epithelium, loss of cilia, slight inflammatory cell infiltration) and alveolar tissue (focal alveolar septal thickening with slight inflammatory cell infiltration), but no statistically significant differences between the PGI2 and control groups were encountered. CONCLUSION: Our findings indicate the absence of PGI2 aerosol-related respiratory tissue damage after 8-h inhalation of PGI2.

Aerosols↗

Inhalation of prostacyclin (PGI2) for 8 hours does not produce signs of acute pulmonary toxicity in healthy lambs.

OBJECTIVE: To study the potential side effects and toxicity of inhaling prostacyclin (PGI2) aerosol for 8 h. DESIGN: In a prospective, randomized study 14 healthy lambs received either PGI2 (n = 7) or 0.9% NaCl (n = 7) as an aerosol for 8 h. SETTING: Institute for Surgical Research of the Ludwig-Maximilians-University of Munich. INTERVENTIONS: All animals were studied under general anesthesia in a prone position. They were first intubated endotracheally and later tracheotomized. PGI2 solution (median dose 28 ng/kg per min) or 0.9% NaCl was administered with a jet nebulizer (delivery rate 4-10 ml/h; mass median diameter of aerosol particles 3.1 microns). Bronchoalveolar lavage was performed before and after the inhalation period to collect epithelial lining fluid of alveoli. MEASUREMENTS AND RESULTS: Hemodynamic and respiratory parameters, systemic resorption (plasma levels of 6-keto-prostaglandin-F 1 alpha), in vitro bleeding time, collagen-induced platelet aggregation and global biochemical and cellular composition of the epithelial lining fluid were examined in order to assess the side effects and signs of acute pulmonary toxicity induced by inhaled PGI2. No statistically significant differences were found between the PGI2 and the control groups for any of the parameters examined. CONCLUSION: Inhalation of PGI2 (28 ng/kg per min) over a period of 8 h in healthy lambs does not produce major side effects or acute pulmonary toxicity.

Acute Disease↗

Hypovolemic shock and cardiac contractility: assessment by end-systolic pressure-volume relations.

The end-systolic pressure-volume relation (ESPVR) is accepted as a load-independent measure of cardiac contractility. Potential curvilinearity of the ESPVR, dependency on coronary perfusion pressure (CPP) and sensitivity to the type of loading intervention might limit its use in hemorrhagic shock. This study compared ESPVRs obtained by caval and aortic occlusion under physiological loading conditions at baseline with those obtained during hemorrhagic shock (mean arterial pressure 45 mmHg). The left ventricular (LV) pressure (tip manometer) and volume (conductance catheter) were measured in ten anesthetized pigs. ESPVRs were fitted to linear and quadratic models. Within end-systolic pressure (Pes) ranges obtained under baseline conditions, ESPVR displayed only minimal curvilinearity (second-order coefficient a < 0.007) and could be accurately described by a linear model. However, nonlinearity of ESPVRs obtained over wider load ranges is suggested by negative volume axis intercepts of the linear model. Steeper ESPVR with aortic than with caval occlusion (2.28 +/- 0.22 vs 3.41 +/- 0.51 mmHg/ml, ns) could not be proven owing to the large interindividual variance of ESPVR slopes with both loading interventions. During shock the Pes range obtained by caval occlusion decreased to very low levels (from 49 +/- 2 to 34 +/- 1 mmHg), ESPVR did not adequately fit either of the two models (mean R < 0.66), and critical reduction of CPP induced negative ESPVR slope in four of ten experiments. In contrast, aortic occlusion at shock resulted in linear ESPVR (R = 0.927 +/- 0.029), Pes ranges (92 +/- 3 to 58 +/- 4 mmHg) comparable to the ones obtained by caval occlusion at control (113 +/- 5 to 73 +/- 6 mmHg), and steeper ESPVR than at control (3.41 +/- 0.51 to 7.38 +/- 1.0 mmHg/ml, P < 0.05). Interpretation of the increased ESPVR slope obtained with aortic occlusion as due to increased contractility in shock is, however, complicated by different Pes ranges. It is concluded that within Pes ranges obtained with caval or aortic occlusion in situ the ESPVR can be adequately fitted to a linear model. For assessment of the inotropic response to shock the ESPVR is of limited value because (1) caval occlusion is not suitable to generate ESPVR during shock, and (2) Pes ranges obtained with identical loading interventions differ greatly between baseline and shock and, therefore, apparent ESPVR changes are influenced by the potential nonlinearity of the ESPVR. Combining caval occlusion at baseline with aortic occlusion at shock would result in comparable Pes ranges. Interpretation of results is, however, complicated by diverging effects of the different loading interventions on the shape and slope of the ESPVR.

Animals↗

Determination of regional pulmonary blood flow with systemically injected nonentrapped microspheres.

Radioactive microspheres (MS) injected into the systemic circulation shunt to the venous side of the circulation and are trapped in the lung vasculature. We hypothesized that regional pulmonary perfusion could be determined by using systemically injected shunted MS. In seven anesthetized mechanically ventilated foxhounds, regional pulmonary perfusion was measured at baseline and during experimental acute respiratory distress syndrome with MS injected into both the right and left atrium (protocol 1). Methodological error of the MS technique was assessed by simultaneous injection of two different batches of MS into the right atrium (protocol 2). Measurement of perfusion during baseline and during experimental acute respiratory distress syndrome with shunted MS had a mean bias of 0.8 and 5.6% and mean precision of 19.2 and 34.7% (r = 0.94 and r = 0.95), respectively, compared with data from nonshunted MS. Simultaneous perfusion measurements displayed bias of -2.7 and 6% and precision of 8.2 and 5.3% (r = 0.98 and r = 0.99), respectively. Systemic shunt should be high for this method to prevent bronchial circulation from imposing significant error. We conclude that systemically injected MS can be used for simultaneous measurement of regional systemic and regional pulmonary perfusion, provided that MS that shunted in the first pass are measured in lung tissue.

Animals↗

Inhaled prostacyclin (PGI2) versus inhaled nitric oxide in adult respiratory distress syndrome.

Inhalation of nitric oxide (NO) and prostacyclin (PGI2) may induce selective pulmonary vasodilation and-by improving ventilation-perfusion ratio in ventilated areas of the lung-increase Pao2 in patients with acute lung injury. To assess the therapeutic efficacy of both compounds, dose-response curves were established in patients with adult respiratory distress syndrome (ARDS). Patients received both PGI2 (doses of 1, 10, and 25 ng/kg/min) and NO (concentrations of 1, 4, and 8 ppm). Cardiorespiratory parameters were assessed at control, at each drug concentration, and after withdrawal of NO and PGI2. PGI2 resulted in a significant, dose-dependent and selective reduction of pulmonary artery pressure (PAP) from 35.1 +/- 6.3 mm Hg at control to 33.1 +/- 4.8 (1 ng/kg/min), 31.3 +/- 4.8 mm Hg (10 ng/kg/min) and 29.6 +/- 4.5 mm Hg (25 ng/kg/min), respectively. Inhaled NO reduced PAP from 34.5 +/- 5.6 to 32.1 +/- 5.9 mm Hg at 4 ppm, and to 31.8 +/- 6.1 mm Hg at 8 ppm, respectively, with no effect at 1 ppm. Pao2/Flo2 ratio increased from 105 +/- 37 to 125 +/- 56 mm Hg (range of increase: 0 to 57 mm Hg) at PGI2 10 ng/kg/min and to 131 +/- 63 mm Hg (range: -5 to 89 mm Hg) at 25 ng/kg/min with no effect at 1 ng/kg/min. NO improved Pao2 (e.g., from 116 +/- 47 to 167 +/- 86 mm Hg at 8 ppm) and reduced intrapulmonary shunt at all doses tested. We conclude that both inhaled PGI2 and NO may induce selective pulmonary vasodilation and increase Pao2 in severe ARDS.

APACHE↗

Inhaled sodium nitroprusside. Non-selective reduction of thromboxane analogue-induced pulmonary vasoconstriction in healthy sheep.

Both inhaled nitric oxide (NO) and inhaled prostacyclin have been shown to selectively decrease pulmonary hypertension of various origin. The aim of the present study was to assess the potential of the NO donor sodium nitroprusside (SNP) to elicit selective pulmonary vasodilation. SNP spontaneously liberates nitric oxide in the presence of reducing substances like cysteine or glutathione, ubiquitous in many different tissues. Inhaled as an aerosol in 3 healthy lambs presenting pulmonary hypertension induced by infusion of a thromboxane analogue, low concentrations of SNP (0.02-0.6 mg/ml) revealed no effect at all. In contrast, high concentrations of SNP (1.0-20.0 mg/ml) lowered pulmonary artery pressure in conjunction with systemic arterial hypotension, suggesting systemic resorption of SNP with subsequent release of its nitroso-group. Selective pulmonary vasodilation was never observed. In conclusion, the present results do not support a selective effect of inhaled SNP in the pulmonary circulation.

Administration, Inhalation↗

Evaluation of right ventricular function by assessment of cardiac efficiency: influence of induction of anaesthesia in coronary artery bypass grafting patients.

Considering the heart as a physical pump cardiac efficiency is calculated from the ratio of cardiac work performed to the maximum level of energy of the heart. The aim of the study was to compare cardiac efficiency with cardiac output and right ventricular ejection fraction. Nine patients scheduled for coronary artery bypass grafting were investigated. A femoral arterial and a right ventricular ejection fraction pulmonary artery catheter were placed in the awake state. Anaesthesia was induced with eltanolone and fentanyl. Cardiac output, pulmonary artery and central venous pressures, and right ventricular ejection fraction were measured in the awake state (baseline), 2 min after induction of anaesthesia and 1 and 5 min after intubation. Cardiac efficiency was calculated by dividing the stroke work by the maximum energy of the heart as calculated from the pressure volume diagram. An analysis of variance was carried out for cardiac efficiency, cardiac output and right ventricular ejection fraction. Cardiac efficiency was significantly (p < 0.05) reduced 1 min after intubation from 28 +/- 11 to 14 +/- 5%. In contrast the right ventricular ejection fraction (from 48 +/- 10 to 35 +/- 13%) and cardiac output (from 6.5 +/- 1.5 to 5.3 +/- 1.2 L/min) did not change significantly during the induction of anaesthesia. Cardiac efficiency was found to be a more sensitive parameter to describe changes in the right ventricular function than the ejection fraction and cardiac output during induction of anaesthesia with eltanolone and fentanyl which was used as a model to vary cardiac performance and afterload.

Aged↗

Effects of inhaled prostacyclin as compared with inhaled nitric oxide in a canine model of pulmonary microembolism and oleic acid edema.

OBJECTIVE: Recently, it has been shown that the inhalation of nitric oxide (NO) and of prostacyclin (PGI2) elicits selective pulmonary vasodilation in a canine model of pulmonary hypertension induced by hypoxic pulmonary vasoconstriction. The present study was designed to investigate whether inhaled NO or PGI2-aerosol, respectively, is also effective in decreasing pulmonary artery pressure in a canine model of acute pulmonary microembolism and oleic acid edema. DESIGN: Prospective, randomized, cross-over design. SETTING: University animal research laboratory. PARTICIPANTS: Eight anesthetized, mechanically ventilated dogs (28 +/- 1 kg). INTERVENTIONS: Acute pulmonary microembolization (PME) was induced using glass microbeads (mean diameter: 100 microns) and 0.01 mL/kg of oleic acid. Subsequently, inhaled PGI2 (concentration: 10 micrograms/mL) or NO (50 ppm), respectively, was randomly administered for 15 minutes each and then withdrawn. MEASUREMENTS AND MAIN RESULTS: Central hemodynamics (heart rate [HR], cardiac output [CO], stroke volume [SV], mean arterial pressure [MAP], systemic vascular resistance [SVR], mean pulmonary artery pressure [PAP], pulmonary vascular resistance [PVR]) and gas exchange (PaO2/FIO2 ratio, intrapulmonary shunt [Qs/Qt], alveolar-arterial oxygen difference, [AaDO2]) were assessed. Measurements were performed at control, after PME, and during administration of PGI2 and NO, respectively. PME induced a significant increase (p < 0.001) of MAP (+9%), PAP (+68%), and PVR (+163%), whereas HR, CO, and SV remained unchanged and lung function deteriorated. Inhalation of NO slightly decreased PAP (-10%; p < 0.05) and PVR (-26%; p < 0.01) and improved AaDO2 and PaO2/FIO2. In contrast, inhalation of PGI2 had no consistent effect on pulmonary vascular tone or gas exchange. CONCLUSION: The data demonstrate that inhaled NO may elicit selective pulmonary vasodilation and improve gas exchange in a canine model of pulmonary microembolism and respiratory insufficiency. However, the degree of these effects was relatively small. The aerosolization of PGI2 under conditions of positive-pressure ventilation did not exert a significant vasodilatory effect on pulmonary vessels and did not improve pulmonary gas exchange in this model.

Administration, Inhalation↗

Effects of inhaled prostacyclin as compared with inhaled nitric oxide on right ventricular performance in hypoxic pulmonary vasoconstriction.

OBJECTIVE: Recently, inhalation of prostacyclin (PGI2) has been shown to cause selective pulmonary vasodilation. However, the effects of inhaled PGI2 on right ventricular (RV) performance are still unknown and therefore were compared with those of inhaled nitric oxide (NO). DESIGN: Reported measurements design. SETTING: Animal research laboratory. ANIMALS: Six anesthetized, ventilated dogs (28 +/- 2 kg). INTERVENTIONS: Pulmonary hypertension was induced by decreasing FIO2 to 0.09-0.11 ('hypoxic pulmonary vasoconstriction', HPV). Subsequently, a single dose of either NO (50 ppm) or PGI2-aerosol (0.9 +/- 0.3 ng/kg/min) was randomly added to the inspired gas. MEASUREMENTS AND MAIN RESULTS: Measurements were performed before induction of HPV and 10 minutes after application and withdrawal of each drug. Central hemodynamics, global RV function, and local RV function (n = 5, sonomicrometry) were assessed. HPV resulted in an increase of pulmonary artery pressure (PAP), pulmonary vascular resistance (PVR), RV stroke work, right coronary artery flow, maximal rate of RV pressure increase (RV dP/dtmax), and maximal velocity of shortening of contractile elements (Vmax). In contrast, RV ejection fraction, RV end-diastolic volume, RV end-diastolic fiber length, and systolic fiber shortening were unchanged. Both PGI2-aerosol and NO attenuated the HPV-induced increase in PAP and PVR without affecting arterial pressure. NO, but not PGI2, resulted in an increase of RV ejection fraction from 42 to 46% (p < 0.05). Right coronary flow dropped from 29 to 21 mL/min during PGI2 (p < 0.05). RV stroke work, RV dP/dtmax, and Vmax decreased subsequent to both NO and PGI2, whereas local RV function was not affected. CONCLUSIONS: In pulmonary hypertension induced by HPV, PGI2-aerosol and inhaled NO reduced RV afterload and, hence, RV oxygen demand, with only minor changes of stroke volume and cardiac output, indicating an improvement of overall efficiency of RV contraction. RV ejection fraction increased on NO, but not with PGI2. This might be explained by the fact that the reduction of pulmonary vascular resistance during PGI2 amounted to only 65% of the effect of NO. In summary, both inhaled NO and PGI2-aerosol showed beneficial effects on RV performance and may prove helpful in the treatment of acute pulmonary hypertension.

Administration, Inhalation↗

Hypertonic saline dextran does not increase cardiac contractile function during small volume resuscitation from hemorrhagic shock in anesthetized pigs.

Small volumes of hypertonic saline dextran (10% of shed blood volume [SBV] restore cardiac output (CO) and increase arterial pressure in hemorrhagic shock. Besides rapid expansion of plasma volume, a positive inotropic effect has been proposed as an additional mechanism for the immediate onset of the cardiovascular response. This study compares the effects of 7.2% saline/10% dextran 60 (HSDex, n = 8) and normal saline (NS; n = 6) on central hemodynamics and cardiac contractility assessed by end-systolic elastance (Ees; conductance technique) and segmental preload recruitable stroke work (sPRSW; sonomicrometry). In anesthetized open chest pigs (28 +/- 1 kg, mean +/- SEM) shock was induced by blood withdrawal (40% of blood volume) to maintain mean arterial pressure (MAP) at 45 mm Hg for 75 min. Resuscitation was started by bolus infusion (2 min) of either HSDex (10% of SBV) or the identical sodium load of NS (80% of SBV); 30 min later both groups received 6% dextran (10% of SBV). Hemorrhagic shock reduced CO (-45%) and left ventricular end-diastolic volume (Ved; -70%) while Ees increased (NS:2.2 +/- 0.4 to 7.5 +/- 1.8 mm Hg/mL, P < 0.05; HSDex: 1.9 +/- 0.2 to 9.1 +/- 2.6 mm Hg/mL, P = 0.085). Within 5 min after infusion of either solution CO returned to baseline values and MAP (NS +55%, HSDex +64%) and Ved (+100%) increased. Neither HSDex nor NS increased Ees above shock levels (NS, 8.7 +/- 4.9 mm Hg/mL; HSDex, 7.3 +/- 2.6 mm Hg/mL) and no group differences occurred in other measurements of contractility (dP/dt40,sPRSW). Plasma osmolality increased to 328 +/- 3 mOsmol/kg with HSDex.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Prostacyclin aerosol and inhaled nitric oxide fail to reverse pulmonary vasoconstriction induced by thromboxane analogue in dogs.

Inhalation of either prostacyclin (PGI2) as an aerosol or nitric oxide (NO) has been shown to elicit selective pulmonary vasodilation during hypoxic pulmonary vasoconstriction in dogs. Hypoxia may produce cardiovascular changes confounding interpretation of drug effects. Therefore, we investigated the effects of PGI2-aerosol and inhaled NO (50 p.p.m.) on pulmonary pressure-flow relationships (P/Q plots) during thromboxane analogue (U46619) induced pulmonary vasoconstriction. In eight anaesthetized dogs infusion of U46619 (0.33 +/- 0.18 micrograms kg-1 min-1) increased the slope (3.5 +/- 1.1 to 8.4 +/- 1.7 mmHg L-1 min-1, P < 0.001) and the intercept (4.4 +/- 2.3 to 10.2 +/- 4.6 mmHg, P < 0.01) of P/Q plots indicating pulmonary vasoconstriction. Inhalation of both aerosolized PGI2 solution (10 micrograms mL-1) and NO (50 p.p.m.) reduced neither the slope nor the intercept of the P/Q plots. Increasing the concentration of the aerosolized PGI2 solution to 50 micrograms mL-1 (n = 3) did not enhance the effect on pulmonary circulation but systemic vascular resistance fell by 23%. Oxygenation and intrapulmonary shunt remained unchanged during both PGI2-aerosol and inhaled NO. The failure of PGI2-aerosol to induce pulmonary vasodilation indicates that during aerosolization PGI2-concentrations at receptor sites on pulmonary vessels were insufficient to surmount U46619 induced vasoconstriction; this notion is supported by unchanged arterial plasma concentrations of the PGI2 degradation product 6-keto-PGF1 alpha. Considering that NO inhaled at comparable concentrations in sheep reversed U46619 induced pulmonary vasoconstriction, species differences may account for the failure of both PGI2-aerosol and NO to dilate pulmonary vessels in dogs.

15-Hydroxy-11 alpha,9 alpha-(epoxymethano)prosta-5↗