Search PubMed⌕ Search

Biomedical subjects

B Williamson

Publications and source records attributed to B Williamson.

At least 55 records · Page 3Linked to original sources

Medial temporal lobe heterotopia as a cause of increased hippocampal and amygdaloid MRI volumes.

Magnetic resonance imaging (MRI)-based volumetric measurements of the hippocampus and amygdala are useful in detecting hippocampal and amygdaloid sclerosis in patients with temporal lobe epilepsy. In these pathological entities, volumetric MRI analysis shows the epileptogenic structures to be atrophic when compared to the normal, nonepileptogenic side. Described are 2 patients with increased hippocampal and amygdaloid volumes on the side of seizure onset due to medial temporal lobe heteroto pias. Care must be taken in the interpretation of volumetric MRI data to make certain that asymmetries in hippocampal and amygdaloid measurements are due to atrophy and sclerosis of the abnormal side and not to increased tissue such as heterotopic gray matter.

Adult↗

Atrial electrogram characteristics in patients with and without atrioventricular nodal reentrant tachycardia.

BACKGROUND: Multicomponent atrial electrograms and "slow pathway potentials" are helpful in identifying target sites for radiofrequency catheter ablation of the slow pathway in patients with atrioventricular (AV) nodal reentrant tachycardia. The purpose of this study was to compare the atrial electrograms recorded at various locations in the right atrium in patients with and without AV nodal reentrant tachycardia to assess the specificity of multicomponent atrial electrograms and possible slow pathway potentials both for the posteroseptal right atrium and for patients with AV nodal reentrant tachycardia. METHODS AND RESULTS: In 25 patients with AV nodal reentrant tachycardia and 23 control patients without AV nodal reentrant tachycardia or dual AV nodal physiology, atrial electrograms with an AV ratio of < or = 1:2 were recorded at the posteroseptal right atrium near the coronary sinus ostium and in the right atrium near the posterior, lateral, and anterior aspects of the tricuspid annulus. Attempts were made to identify broad, multicomponent, and double atrial electrograms. There were no significant differences between the patients with and without AV nodal reentrant tachycardia in the mean number of deflections in the atrial electrograms or in the mean duration of the atrial electrograms recorded at any of the atrial sites. In all patients, the number of atrial electrogram deflections and the atrial electrogram duration were significantly greater at the posteroseptal position than at the other three atrial sites. The prevalence of potentials with the appearance of slow pathway potentials in the posterior septum was similar in patients with and without AV nodal reentrant tachycardia (68% and 70%, respectively). The prevalence of these potentials was 6% to 25% at the other three atrial sites (P < .005 compared with the posterior septum). CONCLUSIONS: The atrial electrogram characteristics that have been found to be useful in identifying effective posteroseptal slow pathway ablation sites in patients with AV nodal reentrant tachycardia are equally prevalent in patients without AV nodal reentrant tachycardia or dual AV nodal physiology. Atrial electrograms in the posteroseptal area are broader and contain more deflections than at other areas in the right atrium, possibly because of conduction properties of the posterior transitional zone that are independent of the presence of AV nodal reentrant tachycardia.

Adult↗

Analysis of sevoflurane degradation products in vapor phase samples.

Sevoflurane degradation products were measured by GC-flame ionization detection in vapor phase samples using manual and automated injection methods. Sample handling techniques allowed the transfer and storage of samples for up to 72 h. Compound A, fluoromethyl 2,2-difluoro-1-(trifluoromethyl)vinyl ether, was the major vapor phase degradation product formed in simulated clinical conditions. Recoveries of 4-32 ppm (v/v) compound A concentrations using the manual method were in the range of 88-117% (n = 12, mean = 102%, R.S.D. = 9%).

Anesthetics↗

Effect of accessory pathway location on the efficiency of heating during radiofrequency catheter ablation.

During radiofrequency catheter ablation of accessory pathways there is a poor correlation between applied power and temperature at target sites for catheter ablation. This study was designed to examine the relation between power and temperature during radiofrequency catheter ablation in patients with accessory pathways and to identify the factors that affect the efficiency of heating, defined as the ratio of applied power and temperature. Twenty-nine patients underwent radiofrequency catheter ablation of an accessory pathway. Among 257 energy applications, 108 were applied for ablation of a right-sided accessory pathway, 105 for a left-sided accessory pathway, and 44 for a posteroseptal accessory pathway. During each application of radiofrequency energy, temperature was continually monitored by use of an ablation catheter with a thermistor embedded in the tip of the distal electrode. During some applications of energy, fluctuations in temperature were observed. The average power, impedance, temperature, and efficiency of heating for all applications of radiofrequency energy was 37 +/- 11 W, 100 +/- 9 ohms, 53 +/- 9 degrees C, and 1.7 +/- 0.8 degrees C/W (range 0.9 degrees to 6.6 degrees C/W), respectively. The efficiency of heating varied by location (p < 0.0001), with the greatest efficiency of heating for posteroseptal energy applications (2.3 +/- 1.2 degrees C/W, which were significantly greater than for left-sided (1.8 +/- 0.8 degrees C/W; p < 0.01) or right-sided (1.2 +/- 0.4 degrees C/W; p < 0.0001) applications. Phasic fluctuation in temperature was observed during 127 (49%) energy applications, and the efficiency of heating was 1.5 +/- 0.7 degrees C/W.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The end of an era.

Explore the source record for details and available documents.

Chromosome Mapping↗

My guardian angel.

Explore the source record for details and available documents.

Diabetes Mellitus, Type 1↗

Randomized comparison of anatomic and electrogram mapping approaches to ablation of the slow pathway of atrioventricular node reentrant tachycardia.

OBJECTIVES: The purpose of this study was to prospectively compare in random fashion an anatomic and an electrogram mapping approach for ablation of the slow pathway of atrioventricular (AV) node reentrant tachycardia. BACKGROUND: Ablation of the slow pathway in patients with AV node reentrant tachycardia can be performed by using either an anatomic or an electrogram mapping approach to identify target sites for ablation. These two approaches have never been compared prospectively. METHODS: Fifty consecutive patients with typical AV node reentrant tachycardia were randomly assigned to undergo either an anatomic or an electrogram mapping approach for ablation of the slow AV node pathway. In 25 patients randomly assigned to the anatomic approach, sequential radiofrequency energy applications were delivered along the tricuspid annulus from the level of the coronary sinus ostium to the His bundle position. In 25 patients assigned to the electrogram mapping approach, target sites along the posteromedial tricuspid annulus near the coronary sinus ostium were sought where there was a multicomponent atrial electrogram or evidence of a possible slow pathway potential. If the initial approach was ineffective after 12 radiofrequency energy applications, the alternative approach was then used. RESULTS: The anatomic approach was effective in 21 (84%) of 25 patients, and the electrogram mapping approach was effective in all 25 patients (100%) randomly assigned to this technique (p = 0.1). The four patients with an ineffective anatomic approach had a successful outcome with the electrogram mapping approach. On the basis of intention to treat analysis, there were no significant differences between the electrogram mapping approach and the anatomic approach with respect to the time required for ablation (28 +/- 21 and 31 +/- 31 min, respectively, mean +/- SD, p = 0.7) duration of fluoroscopic exposure (27 +/- 20 and 27 +/- 18 min, respectively, p = 0.9) or mean number of radiofrequency applications delivered (6.3 +/- 3.9 vs. 7.2 +/- 8.0, p = 0.6). With both the anatomic and electrogram mapping approaches, the atrial electrogram duration and number of peaks in the atrial electrogram were significantly greater at successful target sites than at unsuccessful target sites. CONCLUSIONS: The anatomic and electrogram mapping approaches for ablation of the slow AV nodal pathway are comparable in efficacy and duration. If the anatomic approach is initially attempted and fails, the electrogram mapping approach may be successful at sites outside the areas targeted in the anatomic approach. With both the anatomic and electrogram mapping approaches, there are significant differences in the atrial electrogram configuration between successful and unsuccessful target sites.

Cardiac Pacing, Artificial↗

Effect of pacing site on the atrial electrogram at target sites for slow pathway ablation in patients with atrioventricular nodal reentrant tachycardia.

Atrial electrograms recorded from target sites during radiofrequency catheter ablation of the slow atrioventricular (AV) nodal pathway are often fractionated and may be associated with a late, high frequency component (the slow pathway potential). The purpose of the current study was to assess the effects of slow pathway ablation on the morphology of the atrial electrogram and to determine whether target site electrograms display direction dependent changes in morphology during atrial pacing maneuvers. Twenty-six patients with typical AV nodal reentry had electrograms recorded from target sites before and after successful ablation of the slow AV nodal pathway and during pacing from the high right atrium and distal coronary sinus at cycle lengths of 500 and 300 msec. There was no significant change in the duration or degree of fractionation of the atrial electrogram as the result of slow pathway ablation. In contrast, the duration and degree of fractionation were less when pacing from the coronary sinus compared with sinus rhythms or right atrial pacing. Pacing rate did not affect electrogram morphology. These data suggest that the morphology of the slow pathway target site electrogram is dependent on the direction of atrial activation and that the "slow pathway potential" does not represent activation of an anatomically discrete pathway.

Adult↗

Pretreatment with corticosteroids to prevent adverse reactions to nonionic contrast media.

OBJECTIVE: The purpose of this study was to determine whether patients receiving a two-dose corticosteroid regimen before IV injection of nonionic contrast medium gain protection against adverse reactions to contrast material. SUBJECTS AND METHODS: A randomized, blinded study involving three institutions was initiated in 1988. Patients were divided into two groups. One group received a 32-mg oral dose of methylprednisolone administered 6-24 hr before and again 2 hr before injection of contrast material. The other group received placebo tablets administered in the same time periods. During a 3-year period, 1155 patients and control subjects successfully completed the protocol. Demographic characteristics, including histories of previous reactions and histories of asthma or allergy, did not differ in the two groups. All signs and symptoms that appeared after injection of contrast material were carefully recorded and graded according to an earlier scheme [1]. Patients, control subjects, and all attending personnel were blinded regarding the premedication. RESULTS: Corticosteroid pretreatment conferred protection for overall reactions (1.7% vs 4.9%, p = .005) and grade I (mild) reactions (0.2% vs 1.9%, p = .004). Subjects receiving corticosteroids also had fewer grade II (moderate) (p = .63) and grade III (severe) (p = .11) reactions, but the total numbers involved were small, and the differences were not significant. CONCLUSION: A rigidly controlled study of the potential protective effects of a two-dose oral corticosteroid regimen preceding IV injection of nonionic contrast medium indicates that corticosteroid pretreatment confers significant protection, at least for overall reactions and grade I reactions.

Administration, Oral↗

A randomized comparison of the right- and left-sided approaches to ablation of the atrioventricular junction.

Radiofrequency ablation of the atrioventricular (AV) junction may be performed using either a right- or left-sided approach. This study prospectively compared the left-sided approach with persistent attempts from the right side in patients in whom initial radiofrequency applications on the right side were unsuccessful. Twenty-one of 54 patients did not have complete AV block induced after 3 right-sided radiofrequency applications. These 21 patients were randomly assigned to undergo either the left-sided approach (n = 10) or to undergo additional attempts from the right side (n = 11). The right-sided approach was performed by positioning the ablation catheter to record the largest possible atrial and His bundle electrograms. The left-sided approach was performed by positioning the ablation catheter along the left ventricular septum, where a His bundle potential was recorded. If either approach was not successful after an additional 17 radiofrequency applications, the alternative approach was then used. The AV junction was successfully ablated in all 10 patients randomized to the left-sided approach, but in only 6 of 11 patients randomized to persistent right-sided attempts (p < 0.05). The 5 patients in whom the AV junction was not successfully ablated using the right-sided approach underwent the left-sided approach and had a successful outcome after a mean of 1.2 +/- 0.4 radiofrequency applications. The left-sided approach required significantly fewer radiofrequency applications after randomization than the right-sided approach (3 +/- 3.4 vs 11 +/- 7.6, p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Prospective, randomized comparison of conventional and high dose loading regimens of amiodarone in the treatment of ventricular tachycardia.

OBJECTIVES: The purpose of this prospective randomized study was to compare the electrophysiologic effects of conventional and high dose loading regimens of amiodarone in patients with sustained ventricular tachycardia. BACKGROUND: Uncontrolled studies in which patients have been treated with an oral loading dose of 2 to 4 g/day of amiodarone have suggested that, compared with a conventional loading dose, this dosing regimen results in more rapid control of spontaneous ventricular tachycardia and ventricular tachycardia induced by programmed stimulation. METHODS: Patients in whom sustained monomorphic ventricular tachycardia was inducible by programmed stimulation and who were refractory to class I antiarrhythmic medications were randomly assigned to receive either a conventional (n = 15) or a high (n = 17) loading dose of amiodarone. The conventional dose consisted of 600 mg twice a day for 10 days. The high dose regimen consisted of 50 mg/kg body weight per day on days 1 to 3, 30 mg/kg per day on days 4 and 5 and 600 mg twice a day on days 6 to 10. An electrophysiologic test was performed in the baseline state and after 3 and 10 days of therapy. An adequate response to amiodarone was defined as the inability to induce ventricular tachycardia or the ability to induce only relatively slow (cycle length > or = 350 ms) hemodynamically stable ventricular tachycardia. RESULTS: After 3 days of therapy, 2 of 14 patients who received the conventional loading dose and 6 of 15 patients who received the high dose loading regimen had an adequate response to amiodarone (p = 0.08). After 10 days of therapy, four patients in each group had an adequate response to amiodarone (p = NS). Three patients who received the high dose and one patient who received the conventional dose of amiodarone had an adequate response after 3 days of therapy but not after 10 days of therapy. There were significant increases in the sinus cycle length, atrioventricular block cycle length, ventricular effective refractory period and ventricular tachycardia cycle length after 3 and 10 days of therapy compared with baseline values regardless of the dosing regimen. The extent of the effects of amiodarone on these variables after 3 and 10 days of therapy was similar with both dosing regimens. CONCLUSIONS: The therapeutic and electrophysiologic effects of conventional and high dose loading regimens of amiodarone do not differ significantly after 3 or 10 days of therapy. High oral loading doses of amiodarone do not offer any significant clinical advantage over a conventional loading dose of amiodarone for controlling ventricular tachycardia induced by programmed stimulation.

Aged↗

Gene therapy begins.

Explore the source record for details and available documents.

Clinical Trials as Topic↗

Recognition and catheter ablation of subepicardial accessory pathways.

OBJECTIVES: The purpose of this study was to characterize left-sided accessory pathways that traverse the atrioventricular (AV) groove subepicardially and to describe results of radiofrequency catheter ablation within the coronary sinus in the patients studied. BACKGROUND: Radiofrequency catheter ablation has proved to be a safe and effective method for treatment of accessory pathways; however, subepicardial accessory pathways may account for some of the failures encountered during endocardial ablation. METHODS: The study group comprised 51 consecutive patients with a left-sided accessory pathway who were undergoing radio-frequency catheter ablation. Initially, the ablation catheter was introduced into a femoral artery and positioned on the ventricular aspect of the mitral annulus. If this endocardial approach was unsuccessful, the ablation catheter was introduced into the coronary sinus and energy applied at sites with shorter activation times than those recorded from the endocardium. RESULTS: Five (10%) of 51 patients with a left-sided accessory pathway could not have accessory pathway conduction interrupted with a median of 18 endocardial radiofrequency energy applications. Accessory pathway potentials were less frequent during endocardial mapping in these 5 patients than in the 46 patients whose accessory pathway was successfully ablated from the endocardial surface. All five of these patients later had successful ablation using one or two applications of radiofrequency energy from within the coronary sinus. Effective target site electrograms in the coronary sinus were characterized by an accessory pathway potential that was larger than the corresponding atrial or ventricular electrogram. There were no complications or recurrences after ablation within the coronary sinus. CONCLUSIONS: Some left-sided accessory pathways may be difficult to ablate from the endocardial surface because they traverse the AV groove subepicardially. The absence of an accessory pathway potential during endocardial mapping in combination with a relatively large accessory pathway potential within the coronary sinus may be a useful marker of a subepicardial pathway. In this select group of patients, radiofrequency catheter ablation from within the coronary sinus appears to enhance efficacy.

Action Potentials↗