Search PubMed⌕ Search

Biomedical subjects

B Van Meerbeek

Publications and source records attributed to B Van Meerbeek.

At least 19 recordsLinked to original sources

Effects of ceramic surface treatments on the bond strength of an adhesive luting agent to CAD-CAM ceramic.

OBJECTIVES: The objective of this study was to evaluate the effect of different surface treatments on the micro-tensile bond strength (microTBS) of an adhesive luting agent to CAD-CAM ceramic. The hypothesis tested was that neither of the surface treatments would produce higher bond strength of the adhesive luting agent to CAD-CAM ceramic. METHODS: Ceramic specimens of two different sizes (6 mm x 8 mm x 3 mm; 13 mm x 8 mm x 4 mm) were fabricated from ProCAD ceramic blocs (Ivoclar-Vivadent) with a low-speed diamond saw. The ceramic blocks were divided into seven groups and submitted to the following surface treatments: group 1: no treatment; group 2: etching with 37% H(3)PO(4); group 3: etching with 37% H(3)PO(4)+silane; group 4: etching with 37% H(3)PO(4)+silane+adhesive resin; group 5: etching with 4.9% HF acid; group 6: etching with 4.9% HF acid+silane; group 7: etching with HF acid+silane+adhesive resin. After surface treatment, two differently sized porcelain disks were bonded together with a composite luting agent (Variolink II, Ivoclar-Vivadent). The specimens were stored for 24h in distilled water at 37 degrees C prior to microTBS testing. One-way analysis of variance was used to test the influence of surface treatment and Scheffe multiple comparisons test determined pair-wise statistical differences (p<0.05) in microTBS between the experimental groups. RESULTS: The mean microTBSs (standard deviation) are: group 1: 12.8 (+/-4.6)MPa; group 2: 19.1 (+/-5.0)MPa; group 3: 27.4 (+/-11.1)MPa; group 4: 34.0 (+/-8.9)MPa; group 5: 37.6 (+/-8.4) MPa; group 6: 34.6 (+/-12.8)MPa; group 7: 34.5 (+/-5.1)MPa. Statistical significant differences were found between group 1 and groups 3-7, and between group 2 and groups 4-7. All specimens of groups 1-4 exhibited adhesive failures, while a combination of adhesive and mixed (adhesive and cohesive) failures was observed in the specimens of groups 5-7. CONCLUSIONS: The results show that surface treatment is important to bond to ceramic and suggests that etching is needed preferably with hydrofluoric acid than with phosphoric acid.

Acid Etching, Dental↗

Restoring cervical lesions with flexible composites.

OBJECTIVES: Flexure at the tooth cervix has been suggested to dislodge cervical restorations more rapidly. The objective of this randomized controlled clinical trial was to test the hypothesis that a higher composite flexibility better withstands tooth flexure stress. METHODS: One hundred and forty-two non-carious cervical lesions were restored with composites with contrasting stiffness. Seventy-one patients randomly received two cervical restorations placed following two out of the three experimental groups: (1) the three-step etch-and-rinse adhesive Permaquick applied with the stiff micro-hybrid composite Amelogen Hybrid (PMQ/A-Hy, Ultradent), (2) Permaquick applied with the more flexible micro-filled composite Amelogen Microfill (PMQ/A-Mi, Ultradent), or (3) the 'golden standard' three-step etch-and-rinse adhesive Optibond FL applied with the micro-hybrid composite Prodigy (O-FL/Pro, Kerr). RESULTS: The recall rate at 7 years was 80%. No statistically significant difference was found for any of the parameters evaluated neither between both adhesives, nor between both composites (McNemar, p>0.05). Eleven percent of the O-FL/Pro restorations were clinically unacceptable due to loss of retention (5.5%) and severe marginal discoloration (5.5%). In the PMQ-group, 22% of the PMQ/A-Mi restorations (8% loss of retention, 5% severe enamel margin defects, 3% severe dentin margin defects, 6% severe marginal discoloration, 3% extreme sensitivity) and 19% of the PMQ/A-Hy restorations (13% loss of retention, 3% severe enamel margin defects, 3% severe marginal discoloration) needed repair or replacement. SIGNIFICANCE: The clinical performance of the three adhesive/composite combinations was good and reliable during the 7-year clinical trial. It was concluded that the composite stiffness does not affect the clinical longevity of cervical composite restorations.

Composite Resins↗

Bonding effectiveness of adhesive luting agents to enamel and dentin.

OBJECTIVES: The bonding effectiveness of five adhesive luting agents to enamel and dentin using different application procedures was determined using a micro-tensile bond strength protocol (microTBS). METHODS: Enamel/dentin surfaces of human third molars were flattened using a high-speed diamond bur. Composite resin blocks (Paradigm, 3M ESPE) were luted using either Linkmax (LM; GC), Nexus 2 (NX; Kerr), Panavia F (PN; Kuraray), RelyX Unicem (UN; 3M ESPE) or Variolink II (VL; Ivoclar-Vivadent), strictly following manufacturers' instructions. For some luting agents, modified application procedures were also tested, resulting in four other experimental groups: Prompt L-Pop+RelyX Unicem (PLP+UN; 3M ESPE), Scotchbond Etchant+RelyX Unicem (SE+UN; 3M ESPE), Optibond Solo Plus Activator+Nexus 2 (ACT+NX; Kerr) and K-Etchant gel+Panavia-F (KE+P; Kuraray). The experimental groups were classified according to the adhesive approach in self-adhesive (UN), etch-and-rinse (ACT+NX, NX, KE+P, SE+UN and VL when bonded to enamel) and self-etch adhesive luting agents (LM, PLP+UN, PN and VL when bonded to dentin). The specimens were stored for 24h in distilled water at 37 degrees C prior to microTBS testing. The Kruskal-Wallis test was used to determine pairwise statistical differences (p<0.05) in microTBS between the experimental groups. RESULTS: When bonded to enamel, ACT+NX (15 MPa) and UN (19.6 MPa) scored significantly lower than VL (49.3 MPa), LM (49.2 MPa), PN (35.4 MPa) and SE+UN (35.2 MPa), while PLP+UN (23.5 MPa) showed a significantly lower microTBS than VL (49.3 MPa) and LM (49.2 MPa). No significant differences were noticed between VL (49.3 MPa), LM (49.2 MPa), NX (37.9 MPa), KE+PN (38.8 MPa), PN (35.4 MPa) and SE+UN (35.2 MPa). Regarding the bonding effectiveness to dentin, all luting agents bonded equally effectively (UN: 15.9 MPa; LM: 15.4 MPa; PN: 17.5 MPa; NX: 22.3 MPa), except VL (1.1 MPa), SE+UN (5.9 MPa) and ACT+NX (13.2 MPa). VL revealed an exceptionally high number of pre-testing failures, most likely due to a combined effect of not having cured the adhesive separately and an insufficiently light-cured luting agent. SIGNIFICANCE: Following a correct application procedure, the etch-and-rinse, self-etch and self-adhesive luting agents are equally effective in bonding to enamel and dentin. Several factors negatively influenced bond strength such as bonding RelyX Unicem to enamel without prior phosphoric acid etching; no separate light-curing of a light-polymerizable adhesive prior to cementation, use of a light-polymerizing adhesive converted into a dual-polymerizing adhesive, and use of a dual-cure luting agent with a low auto-polymerizable potential.

Acid Etching, Dental↗

Bactericidal effect of Nd:YAG laser irradiation on some endodontic pathogens ex vivo.

AIM: To define the role of neodymium:yttrium-aluminum-garnet (Nd:YAG) lasers in root canal disinfection along with a minimally invasive treatment concept. METHODOLOGY: The hypothesis was tested ex vivo that Nd:YAG laser irradiation has a bactericidal effect on endodontic pathogens inoculated in root canals. Resultant colony-forming unit counts were associated with observations of bacterial cell structural changes using conventional scanning electron microscopy (CSEM) and environmental scanning electron microscopy (ESEM) on inoculated dentine surfaces, following indirect and direct Nd:YAG laser irradiation, respectively. RESULTS: The Nd:YAG laser irradiation (1.5 W, 15 Hz, four times for 5 s) of Enterococcus faecalis inoculated canals resulted in a significant reduction (P < 0.05, Wilcoxon signed rank test) of the bacterial load, meaning a 99.7% kill, but no sterilization. The CSEM procedure verified that the extent of radiation damage was in line with the total amount of laser energy applied. After 2 h of incubation and three cycles of indirect laser treatment (i.e. through a 1-mm-thick dentine disc), no morphologically intact bacteria of Actinomyces naeslundii or Streptococcus anginosus were discernible. However, when micro-colonies of S. anginosus and specially biofilms of E. faecalis were present after 2 days, the in situ experiment using ESEM and direct laser treatment showed that bacterial eradication was reduced in deep layers. CONCLUSIONS: The Nd:YAG laser irradiation is not an alternative but a possible supplement to existing protocols for canal disinfection as the properties of laser light may allow a bactericidal effect beyond 1 mm of dentine. Endodontic pathogens that grow as biofilms, however, are difficult to eradicate even upon direct laser exposure.

Actinomyces↗

Development of a self-etch adhesive for resin-modified glass ionomers.

The favorable self-adhesiveness of resin-modified glass ionomers (RMGIs) might be even further improved if the time-consuming and technically sensitive etch-and-rinse pre-treatment step with polyalkenoic acids could be avoided. We undertook this study to assess the effectiveness of an experimental self-etch adhesive for RMGIs that does not need to be rinsed off. Ultrastructural analysis and micro-tensile bond strength testing to enamel and dentin of a RMGI restorative material and a RMGI adhesive were performed after 4 different surface pre-treatments: no conditioning; 25% polyalkenoic acid; an experimental self-etch adhesive; and 37.5% phosphoric acid followed by the experimental self-etch adhesive. The use of an experimental self-etch adhesive increased the bond strength of RMGIs, especially after an additional conditioning step. Interfacial analysis showed the formation of a thin hydroxyapatite-containing hybrid layer. The self-etch technique enhances the user-friendliness of RMGIs and lowers their technique-sensitivity, while maintaining desirable characteristics of the conventional etch-and-rinse approach with polyalkenoic acids.

Acid Etching, Dental↗

Chemical interaction of phosphoric acid ester with hydroxyapatite.

Among functional monomers used in contemporary dental adhesives, 10-methacryloyloxydecyl dihydrogen phosphate (MDP) has been found to interact chemically with hydroxyapatite (HAp) most intensively and stably. This effect was thought to be the basis of the superior bonding effectiveness of MDP-based self-etch adhesives to enamel/dentin. To elucidate fully the chemical interaction and reactivity of MDP with HAp, we used (31)P CP-MAS NMR spectroscopy and powder x-ray diffraction. In an aqueous ethanol solution, Ca ions were leached from HAp to form, at short term, a MDP-calcium salt (CaMHP(2)) layered structure on the HAp surface. When MDP was allowed to interact for longer time (< 24 hrs), CaHPO(4).2H(2)O precipitated on top of this MDP-calcium salt layered structure. In conclusion, the intense chemical interaction of MDP with HAp must be ascribed to superficial dissolution of HAp induced by the MDP adsorption and subsequent deposition of MDP-calcium salt with a solubility lower than that of CaHPO(4).2H(2)O.

Adsorption↗

Extension of a one-step self-etch adhesive into a multi-step adhesive.

UNLABELLED: One-step self-etch adhesives are undoubtedly the most user-friendly adhesives, but have been associated with lower bonding effectiveness as compared to two-step and three-step adhesives. Conversion of a one-step self-etch system into a two-step self-etch adhesive by adding a bonding step, or into a three-step etch&rinse adhesive by adding a beforehand etching step and a bonding step might be tempting in order to improve bond strength. OBJECTIVES: The objective of this study was to investigate whether adding application steps influences the bond strength of a one-step self-etch adhesive. METHODS: In this study, the bonding effectiveness of two experimental one-step self-etch adhesives and three different commercial adhesives to enamel and dentin was determined using a micro-tensile bond-strength protocol. This procedure was repeated for the experimental adhesives transformed into two-step self-etch and three-step etch&rinse adhesives. In addition, their interaction with tooth tissue was investigated using TEM and Feg-SEM. RESULTS: Transforming a one-step into a two-step self-etch adhesive did improve the bond strength to enamel and dentin, though not significantly. By adding a preceding etching step, the bond strength to enamel was significantly improved, but that to dentin was decreased considerably. The latter must be attributed to hampered resin infiltration of the one-step self-etch adhesive within the relatively deeply exposed collagen fibril network. SIGNIFICANCE: Additional application of a hydrophobic bonding agent slightly improved bonding effectiveness. Adding a preceding etching step is beneficial for enamel but should be avoided for dentin as this will decrease bond strengths, and may even jeopardize the bonding durability.

Acetone↗

Bond strength of a mild self-etch adhesive with and without prior acid-etching.

UNLABELLED: The self-etch approach provides dentists with a generation of user-friendly and less technique-sensitive adhesives. Nevertheless, some concern has been raised regarding their bonding effectiveness to enamel, in particular when so-called 'mild' self-etch adhesives are employed. OBJECTIVES: The purpose of this study was to test the hypothesis that the two-step self-etch adhesive Clearfil SE Bond (C-SE; Kuraray, Osaka, Japan) bonds equally effective to enamel/dentin either with or without prior etching with phosphoric acid. METHODS: Bur-cut enamel/dentin surfaces prepared from human molars were partially split in two halves by cutting a shallow groove. One half was first etched with 40% phosphoric acid (K-etchant), while protecting the other half by holding a razor blade in the groove. Next, C-SE was applied strictly following the manufacturer's instructions, after which the surface was built up using Z100 (3M Espe). After 24-h water storage, micro-specimens were prepared with the interface circularly constricted using a Micro-Specimen Former, prior to micro-tensile bond strength (MPa) measurement. In addition, interfaces of C-SE with enamel/dentin prepared with and without beforehand acid etching were examined by Feg-SEM and TEM. RESULTS: Beforehand etching significantly increased the bonding effectiveness of C-SE to enamel. A clearly more micro-retentive surface was revealed by TEM and Feg-SEM when enamel was etched. Phosphoric-acid etching prior to C-SE application on dentin significantly decreased the muTBS to dentin. TEM provided indications of a low-quality hybrid layer after beforehand phosphoric-acid etching. CONCLUSION: Using C-SE, additional etching with phosphoric acid to improve bonding effectiveness should be limited to enamel.

Acid Etching, Dental↗

Micro-rotary fatigue of tooth-biomaterial interfaces.

The bonding effectiveness of restorative materials to tooth tissue is typically measured statically. Clinically tooth/composite bonds are however subjected to cyclic sub-critical loads. Therefore, in vitro fatigue testing of dental adhesives should predict better the in vivo performance of adhesives. The objective of this study was to determine the fatigue resistance of two representative adhesives, a self-etch and an etch&rinse adhesive, bonded to enamel and dentin. Therefore, tooth/composite interfaces were cyclically loaded using a miniaturized version of a rotating beam fatigue testing device. Subsequently, the load at which 50% of the specimens fail after 10(5) cycles, was determined as the median micro-rotary fatigue resistance (microRFR). For both adhesives, the microRFR was about 30-40% lower than the corresponding micro-tensile bond strength (microTBS) to both enamel and dentin. Analysis of the fracture surfaces by Feg-SEM revealed typical fatigue fracture patterns. It is concluded that resin/tooth interfaces are vulnerable to progressive damage by sub-critical loads, with the 3-step etch&rinse adhesive being more resistant to fatigue than the 2-step self-etch adhesive.

Adhesiveness↗

Fatigue behavior of packable composites.

The aim of this study was to investigate the flexural fatigue behavior of 11 packable composites. Of each material 30 rectangular samples (1.2 x 5 x 35 mm) for flexural fatigue test were prepared. The clamped fracture strength and flexural fatigue limit (FFL) of each material were determined using a custom-made fatigue machine, after storage of the samples for one month in water at 37 degrees C. All data were analyzed using one-way ANOVA and Bonferroni/Dunn's test for multiple comparisons (p<0.05). Regression analysis was used to evaluate the relationship between elastic modulus (Abe et al., 2001), clamped fracture strength or FFL and inorganic filler fraction (vol%). The fracture strengths of all but two materials were in between those of the compact-filled densified composites and the microfine ones. The FFL of the packable composites tested were significantly lower than those of the compact-filled densified composites. Three of the tested materials showed even significantly lower FFL than did the microfine composites. There were statistically significant relationships between both the elastic modulus and the volumetric filler fraction (R(2)=0.974, p=1.990 x 10(-7)). The great diversity in packable composites makes clinical assessment necessary with regard to a justified use in posterior teeth.

Composite Resins↗

Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials.

OBJECTIVES: The purpose of this paper was to review current literature on the clinical effectiveness of contemporary adhesives when used to restore cervical non-carious class-V lesions. Restoration retention in function of time was recorded in order to find out if adhesives with a simplified application procedure are as clinically effective as conventional three-step adhesives. DATA SOURCES: Literature published from January 1998 up to May 2004 was reviewed for university-centred clinical trials that tested the clinical effectiveness of adhesives in non-carious class-V lesions. Restoration-retention rates per adhesive reported in peer-reviewed papers as well as IADR-AADR abstracts and ConsEuro abstracts were included and depicted as a function of time in graphs for each of the five adhesive classes (three- and two-step etch-and-rinse adhesives, two- and one-step self-etch adhesives, and glass-ionomers). The guidelines for dentin and enamel adhesive materials advanced by the American Dental Association were used as a reference. Per class, the annual failure rate (%) was calculated. Kruskal-Wallis analysis and Dwass-Steel-Chritchlow-Fligner pairwise comparisons were used to determine statistical differences between the annual failure percentages of the five adhesive categories. RESULTS: Comparison of retention of class-V adhesive restorations as a measure to determine clinical bonding effectiveness of adhesives revealed that glass-ionomers most effectively and durably bond to tooth tissue. Three-step etch-and-rinse adhesives and two-step self-etch adhesives showed a clinically reliable and predictably good clinical performance. The clinical effectiveness of two-step etch-and-rinse adhesives was less favourable, while an inefficient clinical performance was noted for the one-step self-etch adhesives. SIGNIFICANCE: Although there is a tendency towards adhesives with simplified application procedures, simplification so far appears to induce loss of effectiveness. Clinical performance can be correlated with, and predicted by, appropriate types of laboratory study.

Adhesives↗

Microscopic observation of bacteria: review highlighting the use of environmental SEM.

Throughout the years, various methods have been adopted to investigate bacteria involved in root canal infection and apical periodontitis. This paper reviews the most commonly used microscopic techniques and discusses their possibilities, limitations and sample preparation. In particular, a recently developed variant of scanning electron microscope (SEM), referred to as environmental SEM (ESEM), is highlighted due to its potential impact across the diverse field of biomaterials research. The performance of this ESEM technique for bacterial observation of endodontic pathogens was illustrated by a practical approach. The paper concludes with a discussion on the possible use of ESEM for testing endodontic treatment modalities under environmental conditions in situ.

Bacteria↗

A critical review of the durability of adhesion to tooth tissue: methods and results.

The immediate bonding effectiveness of contemporary adhesives is quite favorable, regardless of the approach used. In the long term, the bonding effectiveness of some adhesives drops dramatically, whereas the bond strengths of other adhesives are more stable. This review examines the fundamental processes that cause the adhesion of biomaterials to enamel and dentin to degrade with time. Non-carious class V clinical trials remain the ultimate test method for the assessment of bonding effectiveness, but in addition to being high-cost, they are time- and labor-consuming, and they provide little information on the true cause of clinical failure. Therefore, several laboratory protocols were developed to predict bond durability. This paper critically appraises methodologies that focus on chemical degradation patterns of hydrolysis and elution of interface components, as well as mechanically oriented test set-ups, such as fatigue and fracture toughness measurements. A correlation of in vitro and in vivo data revealed that, currently, the most validated method to assess adhesion durability involves aging of micro-specimens of biomaterials bonded to either enamel or dentin. After about 3 months, all classes of adhesives exhibited mechanical and morphological evidence of degradation that resembles in vivo aging effects. A comparison of contemporary adhesives revealed that the three-step etch-and-rinse adhesives remain the 'gold standard' in terms of durability. Any kind of simplification in the clinical application procedure results in loss of bonding effectiveness. Only the two-step self-etch adhesives approach the gold standard and do have some additional clinical benefits.

Adhesives↗

Monomer-solvent phase separation in one-step self-etch adhesives.

One-step adhesives bond less effectively to enamel/dentin than do their multi-step versions. To investigate whether this might be due to phase separation between adhesive ingredients, we characterized the interaction of 5 experimental and 3 commercial self-etch adhesives with dentin using transmission electron microscopy. All adhesives were examined for homogeneity by light microscopy. Bonding effectiveness to dentin was determined with the use of a micro-tensile bond-strength protocol. The lower bond strength of the one-step adhesives was associated with light-microscopic observation of multiple droplets that disappeared slowly. Interfacial analysis confirmed the entrapment of droplets within the adhesive layer. The prompt disappearance of droplets upon application of a small amount of HEMA (2-hydroxyethyl methacrylate) or a HEMA-containing bonding agent, as well as the absence of droplets at the interface of all HEMA-containing adhesives, strongly suggests that the adhesive monomers separate from water upon evaporation of ethanol/acetone. Upon polymerization, the droplets become entrapped within the adhesive, potentially jeopardizing bond durability. This can be avoided by strong air-drying of the adhesive, thereby removing interfacial water and thus improving bonding effectiveness.

Acid Etching, Dental↗

Hydrolytic stability of self-etch adhesives bonded to dentin.

Functional monomers chemically interact with hydroxyapatite that remains within submicron hybrid layers produced by mild self-etch adhesives. The functional monomer 10-MDP interacts most intensively with hydroxyapatite, and its calcium salt appeared most hydrolytically stable, as compared with 4-MET and phenyl-P. We investigated the hypothesis that additional chemical interaction of self-etch adhesives improves bond stability. The micro-tensile bond strength (muTBS) of the 10-MDP-based adhesive did not decrease significantly after 100,000 cycles, but did after 50,000 and 30,000 cycles, respectively, for the 4-MET-based and the phenyl-P-based adhesives. Likewise, the interfacial ultrastructure was unchanged after 100,000 thermocycles for the 10-MDP-based adhesive, while that of both the 4-MET- and phenyl-P-based adhesives contained voids and less-defined collagen. The findings of this study support the concept that long-term durability of adhesive-dentin bonds depends on the chemical bonding potential of the functional monomer.

Acid Etching, Dental↗

In vitro effect of nanoleakage expression on resin-dentin bond strengths analyzed by microtensile bond test, SEM/EDX and TEM.

This study evaluated the effect of multiple consecutive adhesive resin coatings of adhesive bonded to human dentin on nanoleakage and resin-dentin bond strength. Resin bonded dentin specimens were prepared using a total-etch adhesive (One-Step Plus) applied as multiple consecutive coating, or using two self-etch adhesive systems (iBond or Fluoro Bond). For the total-etch adhesive, resin application and air evaporation were performed 1, 2, 3, or 4 times. The self-etch adhesives were applied according to manufacturers' instructions. Resin-dentin bonded beams were prepared and immersed in water (control) or ammoniacal silver nitrate. After storage, microtensile bond strengths were measured. The fractured surfaces were examined by scanning and transmission electron microscopy (SEM and TEM), and energy-dispersive X-ray spectrometry (EDX). No significant differences in bond strength were found between water and silver nitrate storage groups. Several types of silver depositions (spotted, reticular, or water trees) were found in adhesive joints. The bond strengths of the single coated specimens of the total-etch adhesive were significantly lower than those receiving 2-4 coatings. Single coats produced more nanoleakage than multiple coats. However, no correlation was found between the bond strengths and nanoleakage between the different adhesives (total-etch adhesive with different conditions or self-etch adhesives).

Acid Etching, Dental↗

Comparative study on adhesive performance of functional monomers.

Mild self-etch adhesives demineralize dentin only partially, leaving hydroxyapatite around collagen within a submicron hybrid layer. We hypothesized that this residual hydroxyapatite may serve as a receptor for chemical interaction with the functional monomer and, subsequently, contribute to adhesive performance in addition to micro-mechanical hybridization. We therefore chemically characterized the adhesive interaction of 3 functional monomers with synthetic hydroxyapatite, using x-ray photoelectron spectroscopy and atomic absorption spectrophotometry. We further characterized their interaction with dentin ultra-morphologically, using transmission electron microscopy. The monomer 10-methacryloxydecyl dihydrogen phosphate (10-MDP) readily adhered to hydroxyapatite. This bond appeared very stable, as confirmed by the low dissolution rate of its calcium salt in water. The bonding potential of 4-methacryloxyethyl trimellitic acid (4-MET) was substantially lower. The monomer 2-methacryloxyethyl phenyl hydrogen phosphate (phenyl-P) and its bond to hydroxyapatite did not appear to be hydrolytically stable. Besides self-etching dentin, specific functional monomers have additional chemical bonding efficacy that is expected to contribute to their adhesive potential to tooth tissue.

Adhesiveness↗

Bonding efficacy of polyalkenoic acids to hydroxyapatite, enamel and dentin.

Previously, we introduced a methodology to determine the chemical bonding potential of polyalkenoic acids to mineralized tissues through quantification of the degree of ionic bond formation between the carboxyl groups of a polyalkenoic acid with calcium of hydroxyapatite. In a continuation of that study, we now investigated in how far the chemical bonding potential to synthetic hydroxyapatite is influenced by the molecular structure of the polyalkenoic acid and if this also may affect the self-adhesiveness to enamel and dentin. X-ray photoelectron spectroscopy and inductively coupled plasma atomic emission spectrometry were used to quantitatively analyze the chemical bonding efficacy of a polyalkenoic acid consisting of acrylic acid units (PAA) to synthetic hydroxyapatite (HAp) in comparison to the chemical bonding potential of the previously investigated synthesized polyalkenoic acid (s-PA) co-polymer consisting of 90w/w% acrylic and 10w/w% maleic acid units. In addition, the analysis was carried out for enamel and dentin samples. PAA revealed a significantly lower bonding effectiveness with only half of its carboxyl groups bonded to HAp versus about two-third of the carboxyl groups of s-PA. The difference in bonding potential was confirmed by the considerably lower adhesiveness of PAA to enamel and dentin as compared to that of s-PA The present findings indicate that the molecular structure of the polyalkenoic acid significantly influences the chemical bonding efficacy to Hap-based substrates.

Acrylic Resins↗