Search PubMed⌕ Search

Biomedical subjects

B Tighe

Publications and source records attributed to B Tighe.

15 recordsLinked to original sources

Chaos-induced pulse trains in the ionization of hydrogen.

We predict that a hydrogen atom in parallel electric and magnetic fields, excited by a short laser pulse to an energy above the classical saddle, ionizes via a train of electron pulses. These pulses are a consequence of classical chaos induced by the magnetic field. We connect the structure of this pulse train (e.g., pulse size and spacing) to fractal structure in the classical dynamics. This structure displays a weak self-similarity, which we call "epistrophic self-similarity." We demonstrate how this self-similarity is reflected in the pulse train.

Journal Article↗

Geometry and topology of escape. I. Epistrophes.

We consider a dynamical system given by an area-preserving map on a two-dimensional phase plane and consider a one-dimensional line of initial conditions within this plane. We record the number of iterates it takes a trajectory to escape from a bounded region of the plane as a function along the line of initial conditions, forming an "escape-time plot." For a chaotic system, this plot is in general not a smooth function, but rather has many singularities at which the escape time is infinite; these singularities form a complicated fractal set. In this article we prove the existence of regular repeated sequences, called "epistrophes," which occur at all levels of resolution within the escape-time plot. (The word "epistrophe" comes from rhetoric and means "a repeated ending following a variable beginning.") The epistrophes give the escape-time plot a certain self-similarity, called "epistrophic" self-similarity, which need not imply either strict or asymptotic self-similarity.

Fractals↗

The ex vivo wettability of soft contact lenses.

PURPOSE: To investigate the ex vivo wettability of Etafilcon A contact lenses over an eight hour period of wear and observe the influence of surfactant pre-treatment. METHODS: Etafilcon A hydrogel lenses, comprising poly[2-hydroxyethyl methacrylate-co-methacrylic acid] and 58% water, were soaked for 12 hours in either 0.9% saline (control) or a 1% aqueous solution of poloxamine 1107 (treated). The advancing and receding contact angles were subsequently determined ex vivo after various periods of wear in six adapted contact lens wearers using a single-blind, randomised protocol. Contact angles were measured with a dynamic contact angle tensiometer, using the Wilhelmy plate technique. Patient comfort scores were recorded and the static surface tensions of the probe fluids assessed. RESULTS: Control lenses exhibited no change in wetting angles over time, indicating a lack of surface modification by components within the tear film. Treated lenses exhibited a significantly reduced advancing angle (p < 0.001) and hysteresis angle (p < 0.001) when compared with control lenses. In addition, treated lenses were consistently rated as being more comfortable than control lenses (p = 0.04). CONCLUSIONS: This study has shown clearly that new Etafilcon A lenses do not exhibit significant changes in wettability during the initial four hour wearing period. Pre-treatment of such lenses with a polymeric surfactant results in wetting of the lenses due to the adsorption of surfactant. The surfactant is retained by the lens for at least eight hours of wear, resulting in significant improvements in subjective comfort, especially over the first 30 minutes of wear.

Adolescent↗

An in vivo comparison of the kinetics of protein and lipid deposition on group II and group IV frequent-replacement contact lenses.

PURPOSE: To investigate the degree and rate of deposition of protein and lipid on FDA group II and group IV contact lens materials over a period of up to 28 days of wear. METHODS: Twenty-two subjects wore a group IV lens (Acuvue) and a group II lens (Soflens 66) in a randomized, cross-over study. The lenses were randomly worn for periods between 1 and 28 days and then collected for laboratory-based deposition analysis. RESULTS: The group II lenses revealed an increased degree of lipoidal spoilage (p < 0.0001) and the group IV lenses exhibited increased protein spoilage (p < 0.0001). Surface protein for both materials reached a maximum after 1 day and did not increase over the 4-week wearing period (p = NS). Total protein for group IV lenses reached a maximum between 1 and 7 days and then reached a plateau, with no further increase occurring (p = NS), whereas total protein accumulation on the group II lens continued to increase across all time periods (p < 0.05). Lipid deposition on the group IV lens was maximal after 1 day and increased no further (p = NS), whereas lipid deposition on the group II material monotonously increased and progressively built-up over the 4 weeks of wear (p < 0.0001). CONCLUSIONS: The kinetics of contact lens deposition is mediated by the chemical structure of the contact lens material under consideration. Protein deposition occurs rapidly with group IV materials before reaching a maximum, whereas N-vinyl pyrrolidone-containing group II materials progressively accumulate protein and lipid deposits, with no plateau occurring.

Adult↗

Influence of contact lens material surface characteristics and replacement frequency on protein and lipid deposition.

The aim of the study was to quantify the influence of both contact lens material and replacement frequency on protein and lipid deposition. The following hypotheses were tested: (1) both protein and lipid interaction with contact lenses are material-dependent, and (2) the key factors are the material ionicity for the protein deposition and the material chemical composition for the lipid deposition. Three high water content contact lens materials were tested: netrafilcon A (FDA group II, Gentle Touch), etafilcon A (FDA group IV, Acuvue), and vifilcon A (FDA group IV, Focus). Contact lens spoilation was analyzed using ultraviolet spectroscopy and fluorescence spectrophotometry. The results showed that (1) significantly more proteins were deposited on the ionic materials than on the nonionic materials, and that among the ionic materials, the higher the ionicity, the higher the level of protein deposition; (2) there were significantly more surface proteins on the ionic materials after 3 months than after 1 month of wear, but no difference over time was demonstrated for the nonionic materials; and (3) significantly more lipids were deposited onto the surface of vifilcon A than etafilcon A or netrafilcon A, and the presence of vinylpyrrolidone in the vifilcon A formulation was thought to be the cause of increased deposition. The protein and lipid interactions with contact lenses were found to be material- and time-dependent. Protein attraction was found to be related to the material ionicity. The presence of vinylpyrrolidone was a key factor in the attraction of lipids.

Contact Lenses, Hydrophilic↗

Lipid and protein deposition of N-vinyl pyrrolidone-containing group II and group IV frequent replacement contact lenses.

PURPOSE: The purpose of this study was to investigate the degree of protein and lipid deposition that occurs on N-vinyl-2-pyrrolidone (NVP) containing group II (non-ionic, high water content) and NVP containing group IV (ionic, high water content) frequent replacement hydrogel contact lens materials. METHODS: Twenty subjects were fitted with Group II (Vasurfilcon A) and Group IV (Vifilcon A) contact lenses, which were replaced monthly. The lenses were worn as a contralateral pair for 3 consecutive monthly periods. At the end of each monthly period, the lenses were collected for analysis of protein and lipid deposits. Protein deposition (following extraction) was examined by transmission UV and lipoidal deposition was examined using fluorescence spectrophotofluorimetry. RESULTS: There was a significant difference in the lipid and protein deposition profiles between the two materials. The Group II lens deposited approximately 2x more lipid (38 versus 73 fluorescence units; P < 0.0001) and the Group IV lens deposited approximately 17x more protein (488 micrograms versus 28 micrograms; P < 0.0001). Whilst the mean results across months were not significantly different for either protein or lipid (P = NS), the results revealed significant inter- and intra-subject variation. CONCLUSIONS: Protein deposition was predominantly controlled by the ionic charge of the lens materials, whereas the lipid deposition was predominantly determined by the NVP content. This study demonstrates that inter-subject variation and material characteristics significantly influence the deposition profile of hydrogel contact lens materials.

Adolescent↗

Spoilation and clinical performance of monthly vs. three monthly Group II disposable contact lenses.

Twelve subjects were fitted with a high water content, nonionic contact lens (Pilkington Barnes-Hind "Precision UV"), which was either replaced every month for 3 months or worn for 3 consecutive months before replacement occurred. Visual quality, high and low contrast acuity, and comfort were unaltered with either replacement schedule, but overall satisfaction was significantly greater with the shorter replacement schedule (p = 0.04). Front surface wettability revealed a large amount of intersubject variability and was reduced at the 3-month visit with the longer replacement period lenses (p = 0.003). Visible deposits also increased with longer replacement times (p < 0.05). Laboratory-based analytical results showed that both gross lipid and gross extractable protein significantly increased in the 3-month lenses compared with the 1-month lenses, with 44% less lipid accumulation and 60% less protein deposition occurring with the shorter replacement time. The results support the replacement of high water content lenses on a monthly basis.

Adult↗

Early deposition trends on group I (Polymacon and Tetrafilcon A) and group III (Bufilcon A) materials.

One of the problems with hydrophilic contact lenses is that they are susceptible to spoilage. This study investigated the degree of spoilage associate with lenses of various surface changes during the early stages of wear and the effect of surfactant cleaning of lenses at this stage. Ten patients wore a control HEMA lens on one eye and either an ionic (Bufilcon A) or non-ionic (Tetrafilcon A) lens on the other for one week and used a peroxide system for disinfection. The lenses were then replaced with identical lenses, which were also worn for 1 week, with surfactant cleaning added to the care regimen. The lenses then were examined by fluorescence spectroscopy in order that the extent of lipid and protein deposition could be assessed. The results indicate that protein accumulation is highly material dependent, whereas lipid deposition is primarily patient dependent. Also the term "ionic" does not necessarily indicate equally enhanced deposition in all lenses so termed. Surfactant cleaning appears to be of little benefit in reducing deposits during the early stages of wear, its benefit in the long-term being of much greater significance.

Adult↗

Start now.

Explore the source record for details and available documents.

Interprofessional Relations↗