Agreement and repeatability of infrared pupillometry and the comparison method.

OBJECTIVE: To evaluate the accuracy and repeatability of the widely used comparison method of measuring pupil size. DESIGN: Cross-sectional study. PARTICIPANTS: Fourteen eyes of seven healthy myopic subjects were examined. INTERVENTION: Two examiners made two repeated measures of pupil diameters of 14 eyes using Rosenbaum card comparison pupillometry and infrared pupillometry. Subjects fixated on a distant visual acuity chart, and pupils were measured under three luminance conditions. The agreement and inter-rater repeatability of both methods were determined. MAIN OUTCOME MEASURES: Outcomes were pupil diameters, limits of agreement, and coefficient of repeatability of two examiners. RESULTS: The mean difference between the two techniques ranged from 0.3 to 0.5 mm. The limits of agreement within two standard deviations ranged from 2.4 to 2.8 mm. Coefficient of repeatability ranged from 0.6 to 1.4 mm for infrared pupillometry and 1.0 to 1.2 mm for Rosenbaum pupillometry. Inter-rater repeatability of Rosenbaum pupillometry was consistently pupil diameter biased. Pupil diameters measured with the Rosenbaum method were consistently larger than diameters measured with the infrared technique for both examiners under all luminance conditions. CONCLUSIONS: Results indicate that although the mean difference in techniques was small, the range of the agreement between the Rosenbaum and the infrared techniques was large. The Rosenbaum method consistently overestimated pupil diameters and was subject to inter-rater repeatability bias. Rosenbaum pupillometry may not be appropriate when accurate pupil measurements are required. The results have implications for many clinical trials in ophthalmology, including those evaluating refractive surgery that use Rosenbaum comparison pupillometry.

Adult

Comparison of contrast sensitivity in different soft contact lenses and spectacles.

PURPOSE: To compare the visual performance of soft contact lenses and spectacles. METHODS: Twenty eyes of ten patients were examined. Each patient was fit with Acuvue, Cibasoft, and Biomedics contact lenses in random order. LogMar visual acuity and contrast sensitivity using the VectorVision CSV-1000 were measured. RESULTS: There was no significant difference in visual acuity between any contact lenses (P=.15). Contrast sensitivity at 12 cycles/degree was significantly lower for the Cibasoft lens compared to spectacles (P=.04). There was no significant difference between spectacles and contact lenses for remaining spatial frequencies (P=.07-.35). CONCLUSIONS: Visual acuity appears to be an insensitive method for evaluating soft contact lenses. The lathe-cut manufacturing process may be responsible for reduced visual function compared to cast-molded lenses. Further study in this area is needed.

Adult

The missing muscle syndrome in blowout fractures: an indication for urgent surgery.

The purpose to this study was to determine whether early surgical repair is indicated for a severely entrapped inferior rectus muscle following orbital blowout fracture. We report two patients with small blowout fractures, severe entrapment of the inferior rectus muscle, and an absence of the inferior rectus muscle in multiple contiguous coronal computed tomography cuts. At surgery, we released the severely entrapped inferior rectus muscles with resolution of diplopia. We concluded that patients with the "missing muscle syndrome" require urgent surgical intervention and that clinician review of radiologic studies is always prudent.

Adolescent

Difficulties with hydroxyapatite orbital implants in two patients with dysfunctional levator/superior rectus muscle complex.

Hydroxyapatite orbital implants are recognized for their excellent results in anophthalmos. Few complications are reported in the literature. We implanted hydroxyapatite spheres in two patients with acquired anophthalmos and denervated or nonfunctional levator palpebrae superioris and superior rectus muscles. In both patients, the implant rotated anteriorly, obliterating the superior fornix and causing proptosis. Prosthetic fitting was impeded, necessitating surgical revision in both patients. A hydroxyapatite implant may rotate and migrate anteriorly in the presence of a nonfunctional superior rectus muscle, distorting the conjunctival fornices and causing proptosis. This complication calls into question whether muscle-attached orbital implants should be used in patients with significant rectus muscle weakness.

Adolescent