Preparation of the oral tissues for complete denture construction.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to B R Lang.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: The aim of the study was to compare results after 1 and 3 years when single crowns supported by CerAdapt (test) ceramic abutments or CeraOne (control) titanium abutments were loaded. MATERIALS AND METHODS: The material was divided into two groups: in group A, 69 (34 test, 35 control) abutments/crowns from all involved clinics were followed for 1 year; and in group B, 20 (10 test, 10 control) abutments/crowns from one of the clinics were followed for 3 years. RESULTS: No implant failed, giving a cumulative success rate of 100% for the implants. Two CerAdapt abutments in group A fractured, giving a cumulative success rate of 93% for the CerAdapt and 100% for the CeraOne abutments after 1 year. No abutment failed in group B, giving a cumulative success rate of 100% both for the CerAdapt and the CeraOne abutments between 1 and 3 years. The CerAdapt fractures might have been due to the fact that the abutments were impaired through too-extensive preparation and/or had been exposed to a too-high bending moment. Almost no marginal bone loss was recorded, indicating a stable bone situation both at CerAdapt and CeraOne abutments on single-tooth implants. Healthy conditions, with a relatively stable level of the periimplant mucosa in relation to the abutment/crown, were recorded for soft tissues both at CerAdapt and CeraOne abutments. Both clinicians and patients rated the esthetic result as excellent for practically all cases. CONCLUSION: The results demonstrate the esthetic possibilities and the safety of single-tooth replacement when accepted treatment concepts are followed and documented components are used. The tested abutments worked well, although the fractured CerAdapt abutments indicate that ceramic abutments are more sensitive to handling procedures than the titanium abutments.
A longitudinal electromyographic study of the anterior temporal and masseter activity during habitual chewing of apple was performed on 21 subjects provided with immediate complete dentures. At the pretreatment stage, when the patients having an anterior residual dentition were chewing, the peak mean voltages showed low values (range, 48 to 58 microV). After denture placement, there was a further decrease of the temporal activity that persisted to the 6-month stage. After the dentures were relined, a significant increase in chewing force of the temporal muscles was noted at the 1-year stage. During the second year, when no corrections of the dentures were made, the temporal activity decreased below the pretreatment level. The masseter muscle chewing activity generally showed no significant changes during the 2-year observation period. The mean durations of the chewing strokes and chewing cycles were longer than values reported in dentate samples and generally displayed no significant changes during the 2-year period.
The Michigan Computer-Graphics Coordinate Measurement System (MCGCMS) was used to determine the dimensional accuracy of dentures processed by three different techniques: conventional heat compression, microwave, and visible-light activation. Standardized dentures were fabricated from casts made in an RTV silicone mold. All casts were duplicated with hydrocolloid and 42 dentures were made (ie, 14 dentures for each technique). The MCGCMS measured 22 points on two frontal planes to compare master casts to dentures. The results showed no significant difference in overall dimensional accuracy. At specific sites, however, the visible-light-activated technique produced significantly more flange distortion than did either the conventional or microwave techniques.
The Michigan Computer Graphics Coordinate Measurement System was used to measure the wear of three composite resins and an amalgam alloy control. The validity of the Latin Square experimental design for analysis in a clinical study was demonstrated, and statistically significant differences in wear were established for main effect for the materials under investigation. None of the composite resins examined approximated the amalgam alloy control in wear properties. Rank ordering of the materials with respect to wear was possible using this experimental design. Ranking of the materials for wear resistance using this research approach opens up other future research opportunities to correlate such properties as filler particle size, composition, and distribution with the data derived.
The gradual changes in the skeletal and soft-tissue profile of complete denture wearers resulting from residual ridge reduction were studied using profile cephalometric films obtained from 21 subjects during a 2-year period of denture use. The variables for each observation stage were calculated from 58 digitized reference points. During the first 6 months of denture use, a marked anterosuperior rotation of the mandible as a result of ridge resorption caused a similar profile change of the soft-tissue chin and mandibular lip. Continuing ridge reduction resulted in a marked change of mandibular position at the 2-year stage, leading to a pronounced protrusion of the chin and mandibular lip and a more outward position of the maxillary lip.
The Michigan Computer-Graphics Coordinate Measurement System was used to determine the effects of artificial denture teeth on the accuracy of acrylic resin denture bases. Two poly(methyl methacrylate) acrylic resins and two processing techniques were tested. Groups processed with denture teeth reproduced more accurate points than groups processed without denture teeth. Groups processed with a conventional heat-polymerized acrylic resin reproduced more accurate points than groups polymerized with an injection pressing type of acrylic resin.