Effects of donor bone marrow infusion in clinical lung transplantation.

BACKGROUND: We have demonstrated that donor cell chimerism is associated with a lower incidence of obliterative bronchiolitis (OB) in lung recipients, and that donor chimerism is augmented by the infusion of donor bone marrow (BM). We herein report the intermediate results of a trial combining the infusion of donor BM and lung transplantation. METHODS: Clinical and in vitro data of 26 lung recipients receiving concurrent infusion of donor bone marrow (3.0 to 6.0 x 10(8) cells/kg) were compared with those of 13 patients receiving lung transplant alone. RESULTS: Patient survival and freedom from acute rejection were similar between groups. Of the patients whose graft survived greater than 4 months, 5% (1 of 22) of BM and 33% (4 of 12) of control patients, developed histologic evidence of OB (p = 0.04). A higher proportion (but not statistically significant) of BM recipients (7 of 10, 70%) exhibited donor-specific hyporeactivity by mixed lymphocyte reaction assays as compared with the controls (2 of 7, 28%). CONCLUSIONS: Infusion of donor BM at the time of lung transplantation is safe, and is associated with recipients' immune modulation and a lower rate of obliterative bronchiolitis.

Adult↗

A clinical trial combining donor bone marrow infusion and heart transplantation: intermediate-term results.

BACKGROUND: Donor chimerism (the presence of donor cells of bone marrow origin) is present for years after transplantation in recipients of solid organs. In lung recipients, chimerism is associated with a lower incidence of chronic rejection. To augment donor chimerism with the aim to enhance graft acceptance and to reduce immunosuppression, we initiated a trial combining infusion of donor bone marrow with heart transplantation. Reported herein are the intermediate-term results of this ongoing trial. METHODS: Between September 1993 and August 1998, 28 patients received concurrent heart transplantation and infusion of donor bone marrow at 3.0 x 10(8) cells/kg (study group). Twenty-four contemporaneous heart recipients who did not receive bone marrow served as controls. All patients received an immunosuppressive regimen consisting of tacrolimus and steroids. RESULTS: Patient survival was similar between the study and control groups (86% and 87% at 3 years, respectively). However, the proportion of patients free from grade 3A rejection was higher in the study group (64% at 6 months) than in the control group (40%; P =.03). The prevalence of coronary artery disease was similar between the two groups (freedom from disease at 3 years was 78% in study patients and 69% in controls). Similar proportions of study (18%) and control (15%) patients exhibited in vitro evidence of donor-specific hyporesponsiveness. CONCLUSIONS: The infusion of donor bone marrow reduces the rate of acute rejection in heart recipients. Donor bone marrow may play an important role in strategies aiming to enhance the graft acceptance.

Acute Disease↗

Regional low-flow perfusion provides cerebral circulatory support during neonatal aortic arch reconstruction.

OBJECTIVE: Because of concerns regarding the effects of deep hypothermia and circulatory arrest on the neonatal brain, we have developed a technique of regional low-flow perfusion that provides cerebral circulatory support during neonatal aortic arch reconstruction. METHODS: We studied the effects of regional low-flow perfusion on cerebral oxygen saturation and blood volume as measured by near-infrared spectroscopy in 6 neonates who underwent aortic arch reconstruction and compared these effects with 6 children who underwent cardiac repair with deep hypothermia and circulatory arrest. RESULTS: All the children survived with no observed neurologic sequelae. Near-infrared spectroscopy documented significant decreases in both cerebral blood volume and oxygen saturations in children who underwent repair with deep hypothermia and circulatory arrest as compared with children with regional low-flow perfusion. Reacquisition of baseline cerebral blood volume and cerebral oxygen saturations were accomplished with a regional low-flow perfusion rate of 20 mL x kg(-1) x min(-1). CONCLUSIONS: Regional low-flow perfusion is a safe and simple bypass management technique that provides cerebral circulatory support during neonatal aortic arch reconstruction. The reduction of deep hypothermia and circulatory arrest time required may reduce the risk of cognitive and psychomotor deficits.

Aorta, Thoracic↗

In the lung aerosol cyclosporine provides a regional concentration advantage over intramuscular cyclosporine.

BACKGROUND: Acute rejection remains an almost universal complication among lung transplant recipients. Refractory rejection as well as chronic systemic immunosuppression is associated with significant morbidity and mortality. Recent studies suggest that aerosol cyclosporine may address these issues by effectively preventing acute cellular rejection while maintaining low systemic drug concentrations. This study was designed to evaluate the concentrations of cyclosporine in blood and lung tissue after aerosol and intramuscular administration. METHODS: Lewis rats were divided into 4 experimental groups: Groups A (n = 33) and B (n = 30) received aerosol cyclosporine 3 and 5 mg/kg, respectively; Groups C (n = 33) and D (n = 30) received systemic cyclosporine 5 and 15 mg/kg, respectively. We used high-performance liquid chromatography to quantitate blood and lung tissue cyclosporine levels at timed intervals. We used the trapezoidal rule to approximate area under the concentration vs time curve (AUC). RESULTS: Aerosol delivery of cyclosporine resulted in higher and more rapid peak drug levels in lung tissue samples than did systemic delivery. At an equivalent 5 mg/kg dose, the cyclosporine AUC was 3 times higher with aerosol delivery than with intramuscular delivery in lung tissue (477,965 vs 157,706 ng x hour/g, respectively). The lung tissue: blood AUC ratio was highest in the aerosol groups (27.3:1 and 17.4:1) compared with the intramuscular groups (8.1:1 and 9.4:1). CONCLUSION: Local aerosol inhalation delivery of cyclosporine provides a regional advantage over systemic intramuscular therapy by providing higher peak concentrations and greater lung tissue exposure.

Administration, Inhalation↗

Continuously maintaining positive flow avoids endocardial suction of a rotary blood pump with left ventricular bypass.

This study showed the usefulness of maintaining positive pump flow to avoid endocardial suction and as an assist bypass. Three calves were implanted with centrifugal pumps. Hemodynamics and pump parameters were measured at varying pump speeds (from 1,100 to 2,300 rpm). In each test pump, speed was adjusted to create 3 hemodynamic states: both positive and negative flow (PNF), positive and zero flow (PZF), and continuously positive flow (CPF). The pump flow volume was determined during systole (Vs) and diastole (Vd). Vs in PNF was 29.6 ml and was not significantly different from Vs in PZF (p > 0.15). Vd in PNF was significantly different from Vd in PZF (p < 0.05). All bypass rates of PNF were over 30% of pulmonary flow. All PZF bypass rates were between the PNF rate and the CPF rate. These data showed that PZF satisfied the minimum requirement of assist flow and was under 100% bypass. Thus, PZF may avoid endocardial suction.

Analysis of Variance↗

A novel approach with magnetic resonance imaging used for the detection of lung allograft rejection.

OBJECTIVE: Although various techniques have been explored for the detection and quantification of allograft transplant rejection, a practical and reliable method that is noninvasive is still elusive. METHODS: For our magnetic resonance imaging experiments, we have developed a new rat model of heterotopic lung transplantation to the inguinal region. Allogeneic transplants (DA to Brown Norway) were performed with and without cyclosporine A (INN: ciclosporin) treatment, with syngeneic transplants (Brown Norway to Brown Norway) serving as controls (n = 6 per group). Magnetic resonance images were obtained with a gradient echo method before and after injection of ultra-small superparamagnetic iron oxide particles. RESULTS: At day 5, allogeneic transplants without cyclosporine A treatment showed a grade 4 rejection histologically. A significantly lower magnetic resonance signal was seen 24 hours after injection of ultra-small superparamagnetic iron oxide particles compared with the preinjection image (346 +/- 7.6 vs 839 +/- 43.4 arbitrary units; P <. 05). Syngeneic transplants showed no evidence of rejection histologically and no differences in magnetic resonance imaging signals between the images before and after injection of ultra-small superparamagnetic iron oxide particles (863 +/- 18.8 vs 880 +/- 22.5). Allotransplants treated with cyclosporine A showed a grade 2 rejection histologically. The change in magnetic resonance signals in that group was small but showed a significant decrease in signal intensity after injection (646 +/- 10.5 vs 889 +/- 23.5, P <.05). Immunohistochemistry and iron staining of the allografts indicated that ultra-small superparamagnetic iron oxide particles were taken up by the infiltrating macrophages that accumulated at the rejection site. CONCLUSIONS: We have demonstrated a novel approach for the detection of acute lung allograft rejection using magnetic resonance imaging coupled with injection of ultra-small superparamagnetic iron oxide particles. Despite its limitations, our method might be a first step toward a potential clinical application.

Analysis of Variance↗

Evaluation of R-Mix FreshCells in shell vials for detection of respiratory viruses.

The performance of a mixture of mink lung and A549 cell lines in shell vials (MSVs) for the detection of respiratory viruses in 159 specimens was evaluated. MSVs, conventional culture, and direct immunofluorescence assay identified 96, 85, and 67% of the influenza A virus-positive specimens, respectively. MSVs provided both a high degree of sensitivity and rapid turnaround times for the detection of influenza A virus.

Animals↗

Standardized ejection fraction as a parameter of overall ventricular pump function.

To evaluate the pump function of the ventricle, a parameter which (i) incorporates systolic and diastolic function and (ii) separates the heart from preload and afterload is needed. This study utilized ejection fraction (EF), calculated from the end-systolic (ES) and end-diastolic (ED) pressure-volume relationship (PVR) using an arbitrary set of loading conditions. Ten isolated canine hearts with a balloon placed inside the left ventricle were used to determine the ESPVR and EDPVR. An end-diastolic volume (EDV) at a pressure of 15 mmHg and an end-systolic volume (ESV) at 70 mmHg were obtained from the EDPVR and ESPVR, respectively. EF was calculated as (EDV-ESV)/EDV. With low-dose (8 microg/min) and high-dose (40 microg/min) dobutamine infusion, the EF increased from 0.25+/-0.16 to 0.33+/-0.13 and 0.57+/-0.08 (p<0.01), respectively, in conjunction with increases in end-systolic elastance from 3.11+/-0.83 to 3.48+/-1.08 and 5.38+/-1.91 mmHg/ml (p<0.01). It was thus concluded that because the estimation of EF separates the heart from preload and afterload, this method may facilitate comparing overall pump function of hearts beating under different loading conditions.

Animals↗

Survival of HIV-1 in syringes.

We performed a study to determine the duration of survival of HIV-1 in syringes typically used by injectors of illicit drugs (IDUs). We describe the effectiveness of a microculture assay in detecting viable virus in volumes of blood typical of those commonly found inside used syringes. Using this assay and modeling the worse-case situation for syringe sharing, we have recovered viable, proliferating HIV-1 from syringes that have been maintained at room temperature for periods in excess of 4 weeks. The percentage of syringes with viable virus varied with the volume of residual blood and the titer of HIV-1 in the blood. These experiments provide a scientific basis for needle exchange schemes, harm reduction, and other interventions among IDUs that support the nonsharing and removal of used syringes from circulation.

Acquired Immunodeficiency Syndrome↗

Effect of ischemic time on survival in clinical lung transplantation.

BACKGROUND: While there is convincing evidence that prolonged ischemic times correlate with reduced long-term survival in heart transplantation, the effect of ischemic time on outcome in clinical lung transplantation remains controversial. To assess the effect of ischemic time on outcomes in lung transplantation, we reviewed our experience. METHODS: The study was performed by retrospective chart review. RESULTS: First-time lung transplantation was performed on 392 patients between 1988 and 1998. All grafts were flushed with cold crystalloid preservation solution and stored on ice. Ischemic time data were available for 352 of 392 (90%) patients. Ischemic times were grouped as follows: 0 to 4 hours (n = 91), 4 to 6 hours (n = 201), more than 6 hours (n = 60). Ischemic time did not correlate with survival: 3-year actuarial survival = 56% (0 to 4 hours), 58% (4 to 6 hours), 68% (> 6 hours), p = 0.58. There was no significant difference in the incidence of biopsy-proven diffuse alveolar damage in the first 30 days after transplantation (31%, 32%, 38%), episodes of acute rejection in the first 100 days after transplantation (1.9, 1.8, 1.7), duration of intubation (median 3, 4, 3 days), or incidence of obliterative bronchiolitis (23%, 28%, 26%) between the three groups (0 to 4 hours, 4 to 6 hours, > 6 hours, respectively). A diagnosis of diffuse alveolar damage was associated with a significantly worse outcome (1-year survival = 82% versus 54%, p < 0.0001). CONCLUSIONS: In contrast to heart transplantation, pulmonary allograft ischemic time up to 9 hours does not appear to have a significant impact on early graft function or survival. The presence of diffuse alveolar damage on biopsy early after transplantation does not correlate with prolonged ischemic time, but is associated with substantially reduced posttransplantation survival.

Adolescent↗

Transmyocardial laser revascularization in the patient with unmanageable unstable angina.

BACKGROUND: Transmyocardial laser revascularization (TMR) provides relief for patients with chronic angina, nonamenable to direct coronary revascularization. Unmanageable, unstable angina (UUA) defines a subset of patients with refractory angina who are at high risk for myocardial infarction and death. Patients were classified in the UUA group when they had been admitted to the critical care unit with unstable angina for 7 days with three failed attempts at weaning them off intravenous antianginal medications. METHODS: Seventy-six treated patients were analyzed to determine if TMR is a viable option for patients with unmanageable unstable angina. These patients were compared with 91 routine protocol patients (protocol group [PG]) undergoing TMR for chronic angina not amenable to standard revascularization. The procedure was performed through a left thoracotomy without cardiopulmonary bypass. These patients were followed for 12 months after the TMR procedure. Both unmanageable and chronic angina patients had a high incidence of at least one prior surgical revascularization (87% and 91%, respectively). RESULTS: Perioperative mortality (< or = 30 days post-TMR) was higher in the UUAG versus PG (16% vs 3%, p = 0.005). Late mortality, up to 1 year of follow-up, was similar (13% vs 11%, UUAG vs PG; p = 0.83). A majority of the adverse events in the UUAG occurred within the first 3 months post-TMR, and patients surviving this interval did well, with reduced angina of at least two classes occurring in 69%, 82%, and 82% of patients at 3, 6, and 12 months, respectively. The percent improvement in angina class from baseline was statistically significant at 3, 6, and 12 months. A comparable improvement in angina was found in the protocol group of patients. CONCLUSIONS: TMR carried a significantly higher risk in unmanageable, unstable angina than in patients with chronic angina. In the later follow-up intervals, however, both groups demonstrated similar and persistent improvement in their angina up to 12 months after the procedure. TMR may be considered in the therapy of patients with unmanageable, unstable angina who otherwise have no recourse to effective therapy in the control of their disabling angina.

Adult↗

Alternative approach to multivessel coronary disease with integrated coronary revascularization.

OBJECTIVE: Integrated coronary revascularization combines minimally invasive coronary artery bypass grafting (MICABG) with left internal thoracic artery-left anterior descending artery grafting and percutaneous coronary intervention. We hypothesized that integrated coronary revascularization could result in successful revascularization in suitable patients with multivessel coronary artery disease. METHODS: Between September 1996 and January 1998, 31 consecutive patients underwent integrated coronary revascularization. Twenty-two were male; mean age was 69 years (46-86 years) and 42% were older than 75 years. Eight patients (26%) had a Parsonnet score greater than 20%. Left ventricular ejection fraction was 46.3% +/- 12%; 6 patients (19%) had a left ventricular ejection fraction less than 35%. RESULTS: The anastomosis time for MICABG with the internal thoracic artery was 14.6 +/- 5.2 minutes and the operating time was 105 +/- 20 minutes; 28 patients (90%) were extubated in the operating room. The internal thoracic artery anastomosis was patent in all 31 patients (100%). Percutaneous coronary intervention was performed before MICABG in 2 patients (7%), on the same day of MICABG in 16 patients (52%), on postoperative day 1 in 3 patients (9%), and on postoperative days 2 to 4 in 10 patients (32%). Postprocedure length of stay in the hospital was 2.7 +/- 1.0 days and 13 patients (42%) were discharged home on postoperative day 1 or 2. Three patients (9.6%) required repeat target vessel revascularization in the distribution of the previous percutaneous coronary intervention. All patients are alive without angina at a follow-up of 10.8 +/- 3.8 months. CONCLUSION: Our early results demonstrate that integrated coronary revascularization can be performed safely and effectively. Long-term results will be available from a prospective randomized trial now underway to compare integrated coronary revascularization with coronary artery bypass grafting for multivessel coronary artery disease.

Aged↗

Early post-transplant medical compliance and mental health predict physical morbidity and mortality one to three years after heart transplantation.

BACKGROUND: Poor medical compliance has been held responsible for a large proportion of deaths occurring subsequent to initial postoperative recovery. However, beyond clinical reports, there has been little empirical examination of this issue, or of the extent to which major psychiatric disorder and failure to adjust to the transplant predict long-term physical morbidity and mortality. We prospectively examined whether a full range of compliance behaviors and psychiatric outcomes during the first year post-transplant predicted subsequent mortality and physical morbidity through 3 years post-transplant. METHODS: A total of 145 heart recipients who had received detailed compliance and mental health assessments during the first year post-transplant were followed up at 3 years post-transplant. Interview data and corroborative information from family members were used to determine compliance in multiple domains, psychiatric diagnoses, and psychiatric symptomatology during the first year post-surgery. Medical record reviews were performed to abstract data on acute graft rejection episodes, incident cardiac allograft disease (CAD) and mortality from 1 to 3 years post-transplant. RESULTS: After controlling for known transplant-related predictors of outcome, multivariate analyses yielded the following significant (p < 0.05) results: (a) risk of acute graft rejection was 4.17 times greater among recipients who were not compliant with medications; (b) risk of incident CAD was elevated by persistent depression (Odds Ratio, OR = 4.67), persistent anger-hostility (OR = 8.00), medication noncompliance (OR = 6.91), and obesity (OR = 9.92); and (c) risk of mortality was increased if recipients met criteria for Post-Traumatic Stress Disorder related to the transplant (OR = 13.74). CONCLUSIONS: The findings, plus data we have previously reported that showed which patients are most likely to have compliance and psychiatric problems early post-transplant, suggest that interventions focused on maximizing patients' psychosocial status in these areas may further improve long-term physical health outcomes in this population.

Adult↗

Optimal dosing of intravenous tacrolimus following pediatric heart transplantation.

BACKGROUND: Early experience with intravenous tacrolimus at high doses (0.1-0.15 mg/kg/day) was associated with frequent clinical toxicity. The optimal dosing regimen after pediatric heart transplantation is unknown. METHODS: We retrospectively reviewed data on the last 45 pediatric heart transplant recipients to document the time required to achieve therapeutic blood levels and the safety of 2 differing intravenous dosing regimens (tacrolimus 0.03 & 0.05 mg/kg/day as continuous i.v. infusion). Target plasma levels were (1.2-1.7 ng/ml) with levels >2.0 ng/ ml considered toxic, and target whole blood levels were 15-20 ng/ml with levels >25 ng/ml considered toxic. RESULTS: Mean age at transplantation was 7.5 +/- 5.6 years (0.1-18), and 14 were infants. Intravenous tacrolimus was commenced at a mean of 7 +/- 3 hours (range 2-16) after arrival in the ICU. Eight patients were excluded from analysis because of protocol modifications. Of the remaining 37 pts, 9 received initial infusion at 0.03 mg/kg/day; 3 (33%) achieved 'therapeutic' levels within 48 hours and 1 patient had a toxic level (27 ng/ml) at 36 hours. Twenty-eight patients received 0.05 mg/kg/day; 18 (64%) achieved therapeutic levels within 48 hours and 9 (32%) developed toxic levels. Patients with toxic whole blood levels had higher tacrolimus levels on first blood assay compared to those who did not develop toxicity (16.4 +/- 3.4 vs 9.3 +/- 3.9, p < .0001; level >10 ng/ml on first assay in 7/7 toxic patients vs 7/19 without toxicity, p = .004). Patients receiving the higher dose regimen had fewer episodes of moderate or severe rejection (> or =Grade 3A) at first biopsy than those receiving the lower dose infusion (32% vs 75%; p = .046). No patient required renal dialysis. CONCLUSIONS: Dosing below 0.05 mg/kg/day may result in clinically important delay in achieving therapeutic levels. Toxicity may be reduced by frequent monitoring of levels for the first 48 hours after transplantation especially when the initial level is >10 ng/ml.

Adolescent↗

Native heart complications after heterotopic heart transplantation: insight into the potential risk of left ventricular assist device.

BACKGROUND: In heterotopic heart transplantation, the donor heart is connected parallel to the recipient's diseased heart. Recipients continue to have risks, such as arrhythmia, thromboembolism, valvular heart disease, and ischemic heart disease which can develop in the native heart. It may serve as a clinical model to study long-term pathophysiologic processes in the native heart of patients with a left ventricular assist device. METHOD: We analyzed the prevalence of long-term complications related to the native heart in the heterotopic heart transplant and attempted to gain insight into the potential risk to a native heart after receiving a left ventricular assist device. RESULTS: Between December 1984 and December 1994, 16 patients (13 men, 3 women, ranging in age from 37 to 60 years) underwent heterotopic heart transplant at the University of Pittsburgh. The 1- and 5-year survival rate after the transplant was 81% and 44%, respectively. Actuarial freedom from complications related to the native heart after 1 year and 4 years was ventricular arrhythmia: 85%, 75%; ischemic disease: 85%, 64%; valvular disease: 100%, 88%; and thromboembolism: 85%, 58%. Of these complications, thromboembolism was not considered in determining actuarial freedom from complications because thromboembolism should be regarded as a device-related complication rather than as a native-heart-related complication for left ventricular assist device recipients. Consequently, actuarial freedom from all complications excluding thromboembolism was 70% after 1 year and 50% after 4 years. In addition, the hazard function curve remains constant up to 80 months after the operation without significant differences among the yearly ratios. CONCLUSIONS: This analysis suggests that cautious observation of the native heart's long-term performance is necessary for the left ventricular assist device recipient.

Adult↗

Rotary blood pump flow spontaneously increases during exercise under constant pump speed: results of a chronic study.

Many types of rotary blood pumps and pump control methods have recently been developed with the goal of clinical use. From experiments, we know that pump flow spontaneously increases during exercise without changing pump control parameters. The purpose of this study was to determine the hemodynamics associated with the long-term observation of calves implanted with centrifugal blood pumps (EVAHEART, Sun Medical Technology Research Corporation, Nagano, Japan). Two healthy female Jersey calves were implanted with devices in the left thoracic cavity. A total of 22 treadmill exercise tests were performed after the 50th postoperative day. During exercise, the following parameters were compared with conditions at rest: heart rate, blood pressure, central venous oxygen saturation (SvO2), pump speed, and pump flow. The pump flow in a cardiac cycle was analyzed by separating the systole and diastole. Compared to the base data, statistically significant differences were found in the following interrelated parameters: the heart rate (66.8 +/- 5.2 vs. 106 +/- 9.7 bpm), mean pump flow (4.8 +/- 0.2 vs. 7.0 +/- 0.3 L/min), and volume of pump flow in diastole (26.0 +/- 1.8 vs. 13.5 +/- 2.5 ml). During exercise, the volume of pump flow in systole was 3 times larger than that measured in diastole. Blood pressure, SvO2, and pump speed did not change significantly from rest to exercise. These results suggested that the mean pump flow depends on the systolic pump flow. Therefore, the increase in the mean pump flow during exercise under constant pump speed was caused by an increase in the heart rate.

Animals↗

Abciximab and excessive bleeding in patients undergoing emergency cardiac operations.

BACKGROUND: Abciximab (ReoPro; Eli Lilly and Co, Indianapolis, IN) is a monoclonal antibody that binds to the platelet glycoprotein IIb/IIIa receptor and produces powerful inhibition of platelet function. Clinical trials of abciximab in patients undergoing coronary angioplasty have demonstrated a reduction in thrombotic complications and have encouraged the widespread use of this agent. We have observed a substantial incidence of excessive bleeding among patients who receive abciximab and subsequently require emergency cardiac operations. METHODS: The records of 11 consecutive patients who required emergency cardiac operations after administration of abciximab and failed angioplasty or stent placement were reviewed. RESULTS: The interval from the cessation of abciximab administration to operation was critical in determining the degree of coagulopathy after cardiopulmonary bypass. The median values for postoperative chest drainage (1,300 versus 400 mL; p < 0.01), packed red blood cells transfused (6 versus 0 U; p = 0.02), platelets transfused (20 versus 0 packs; p = 0.02), and maximum activated clotting time (800 versus 528 seconds; p = 0.01) all were significantly greater in the early group (cardiac operation < 12 hours after abciximab administration; n = 6) compared with the late (cardiac operation >12 hours after abciximab administration; n = 5) group. CONCLUSIONS: This report suggests that the antiplatelet agent abciximab is associated with substantial bleeding when it is administered within 12 hours of operation.

Abciximab↗