Search PubMed⌕ Search

Biomedical subjects

B Owall

Publications and source records attributed to B Owall.

77 records · Page 5Linked to original sources

The effect of different polishing techniques on the surface roughness of acrylic resin materials.

This study evaluated three methods of surface polishing on acrylic denture base materials. Specimens of three commercial heat-cured acrylic resin materials were finished using burs, sandpaper discs and rubber wheels, and polished with polishing soap, paste, or by application of a UV-light-activated resin sealant. The resulting surface roughness was examined by scanning electron microscopy as well as measured by means of a stylus profile Perthometer. Surface roughness was reduced by polishing. Polishing paste and UV-light-activated resin sealant were more, and equally, effective in reducing surface roughness compared to polishing soap. Polishing paste or UV-light-activated resin sealant may be used to create a smoother surface on acrylic dentures.

Acrylic Resins↗

Precision attachment retained removable partial dentures: 1. Technical long-term study.

Patients provided with 53 distal extension-base removable partial dentures retained using rigid intracoronal slide attachments were followed up to 25 years. The initial treatment consisted of fixed partial dentures involving all remaining teeth in the treated arches and removable partial dentures having a cast cobalt-chromium framework. The removable dentures showed few complications and little need for relining. The failures primarily involved the fixed partial dentures. Seven arches required complete dentures as a result of technical complications in five patients. Cement failures, root fractures, and fractures of the fixed prostheses were most problematic. The survival rate was about 65% up to 15 years, and a survival time of 50% was extrapolated to 20 years.

Adult↗

Precision attachment-retained removable partial dentures: Part 2. Long-term study of ball attachments.

Patients provided with 24 ball attachment-retained removable partial dentures were followed up to 23.5 years. The prosthetic treatment included fixed partial dentures in 8 arches, and combinations of crowns and splint bars in 16 arches. All ball attachment matrices were supplied with vertical occlusal stops in contact with the patrices. A nonresilient hinged coupling was established between fixed partial dentures and removable partial dentures. Seventeen arches had only two or three remaining teeth. A total of 66 abutments for fixed partial dentures were included, 30 of which were root canal treated and supplied with posts. No technical failures (loss of retention/cement failure, root or tooth fracture, metal framework fracture) with the fixed partial dentures were recorded. With the removable partial dentures, additional retention with clasps was introduced in 2 of the dentures (in addition to 8 originally), 2 had to be remade after fractures, and 4 dentures were relined.

Adult↗