Intermittent pacemaker dysfunction caused by digital mobile telephones.

OBJECTIVES: This study was designed to evaluate possible interactions between digital mobile telephones and implanted pacemakers. BACKGROUND: Electromagnetic fields may interfere with normal pacemaker function. Development of bipolar sensing leads and modern noise filtering techniques have lessened this problem. However, it remains unclear whether these features also protect from high frequency noise arising from digital cellular phones. METHODS: In 39 patients with an implanted pacemaker (14 dual-chamber [DDD], 8 atrial-synchronized ventricular-inhibited [VDD(R)] and 17 ventricular-inhibited [VVI(R)] pacemakers), four mobile phones with different levels of power output (2 and 8 W) were tested in the standby, dialing and operating mode. During continuous electrocardiographic monitoring, 672 tests were performed in each mode with the phones positioned over the pulse generator, the atrial and the ventricular electrode tip. The tests were carried out at different sensitivity settings and, where possible, in the unipolar and bipolar pacing modes as well. RESULTS: In 7 (18%) of 39 patients, a reproducible interference was induced during 26 (3.9%) of 672 tests with the operating phones in close proximity (<10 cm) to the pacemaker. In 22 dual-chamber (14 DDD, 8 VDD) pacemakers, atrial triggering occurred in 7 (2.8%) of 248 and ventricular inhibition in 5 (2.8%) of 176 tests. In 17 VVI(R) systems, pacemaker inhibition was induced in 14 (5.6%) of 248 tests. Interference was more likely to occur at higher power output of the phone and at maximal sensitivity of the pacemakers (maximal vs. nominal sensitivity, 6% vs. 1.8% positive test results, p = 0.009). When the bipolar and unipolar pacing modes were compared in the same patients, ventricular inhibition was induced only in the unipolar mode (12.5% positive test results, p = 0.0003). CONCLUSION: Digital mobile phones in close proximity to implanted pacemakers may cause intermittent pacemaker dysfunction with inappropriate ventricular tracking and potentially dangerous pacemaker inhibition.

Aged

Prolonged decrease in heart rate variability after elective hip arthroplasty.

The pattern of postoperative heart rate variability may provide insight into the response of the autonomic nervous system to anaesthesia and surgery. We have obtained spectral (fast Fourier transform) and non-spectral indices of heart rate variability from electrocardiographic recordings, sampled during continuous perioperative Holter monitoring in 15 otherwise healthy patients with an uncomplicated postoperative course, undergoing elective hip arthroplasty with either spinal or general anaesthesia. In both groups, total spectral energy (0.01-1 Hz), low-frequency spectral energy (0.01-0.15 Hz) and high-frequency spectral energy (0.15-0.40 Hz) decreased after surgery to 32% (95% confidence interval (CI) 10.5; P < 0.01), 29% (95% CI 12.5; P < 0.01) and 33% (95% CI 12.5; P < 0.01) of their preoperative values, respectively, and these indices remained suppressed for up to 5 days. Non-spectral indices decreased to a similar extent. These findings indicate a substantial and prolonged postoperative decrease in both parasympathetic and sympathetic influence on the sinus node.

Aged