Search PubMed⌕ Search

Biomedical subjects

B Meier

Publications and source records attributed to B Meier.

At least 91 records · Page 5Linked to original sources

Mechanical compression of coronary artery stents: potential hazard for patients undergoing cardiopulmonary resuscitation.

Mechanical compression of coronary artery stents may be associated with a fatal outcome as the result of refractory myocardial ischemia. We present the history of an 83-yr-old patient, who died owing to hemorrhagic shock 3 days after stent implantation, despite immediate cardiopulmonary resuscitation (CPR). Postmortem examination showed stent compression, probably due to mechanical deformation during CPR. This complication has been reported in two other cases in the literature, suggesting that CPR may be hazardous to patients with coronary artery stents.

Aged↗

Efficacy of Vitex agnus castus L. extract Ze 440 in patients with pre-menstrual syndrome (PMS).

In a prospective, multicentre trial the efficacy of an Vitex agnus castus L extract Ze 440 was investigated in 50 patients with pre-menstrual syndrome (PMS). The patients were treated daily with one tablet (20 mg native extract) during three menstrual cycles. 43 patients completed the study protocol which encompassed 8 menstrual cycles (2 baseline, 3 treatment and 3 post-treatment). 13/43 patients were receiving concomitant oral contraceptives. 6 patients did not complete the study for reasons not related to study medication, and one patient complained of fatigue possibly related to study medication. All evaluated patients took at least 85% of the prescribed medication. The main effect parameter was the validated Moos' menstrual distress questionnaire (MMDQ), and secondary parameters were a visual analogue scale (VAS; self-assessment) and a global impression scale (GI, self-assessment). The study population was homogenous in age (31.3+/-7.7 years) weight (58.9+/-6.9 kg) and cycle length (28.4+/-0.3 d). The diagnosis was according to DMS-III. At the end of the study, PMS-related symptoms were reduced by treatment. There was a significant score reduction (42.5%) of the MMDQ as the main effect parameter (p<0.001). Symptoms gradually returned after treatment cessation. However, a difference from baseline remained (20%; p<0.001) up to 3 cycles thereafter. 20/43 patients were considered "responders", with a reduction in MMDQ score by at least 50% relative to baseline. At baseline, the VAS score was elevated in the late luteal phase and low at the follicular phase, as expected. During treatment, VAS score decreased in the late luteal phase (47.2%; p<0.01) and remained 21.7% (p<0.001) below baseline after 3 cycles post-cessation of treatment. The low VAS score within the follicular phase remained unchanged over the whole observation period. 38 patients judged the global efficacy moderate to excellent, 5 patients indicated no global efficacy. The number of days patients sustained PMS symptoms was reduced slightly from 7.5 to 6. Resting levels of blood prolactin remained within the physiological range throughout. No differences were seen between patients on or off oral contraceptives. 20 patients reported 37 adverse events (AE). No serious AE were reported. One patint withdrew after four days of treatment due to fatigue and headache. Laboratory safety control parameters were not affected. In conclusion, patients with PMS can be treated successfully with Vitex agnus-castus extract Ze 440, as indicated by clear improvement in the main effect parameter during treatment and the gradual return after cessation of treatment. The main response to treatment seems related to symptomatic relief rather than to the duration of the syndrome.

Adult↗

Bisanthraquinone glycosides of Hypericum perforatum with binding inhibition to CRH-1 receptors.

Four new bisanthraquinone glycosides, S-(+)-skyrin-6-O-beta-glucopyranoside (1), R-(-)-skyrin-6-O-beta-glucopyranoside (2), S-(+)-skyrin-6-O-beta-xylopyranoside (3) and S-(+)-skyrin-6-O-beta-alpha-arabinofuranoside (4), have been isolated from an ethanol-water (1:1, v/v) dry extract of the aerial parts of Hypericum perforatum L. The structures were elucidated by spectroscopic methods, mainly NMR and mass spectrometry. Circular dichroism was used to determine their axial stereochemistry revealing 1 and 2 to be atropisomers. 1 and 2 inhibited [125I]sauvagine binding to corticotropin releasing hormone (CRH-1) receptors.

Acetylation↗

Results of transvenous occlusion of secundum atrial septal defects with the fourth generation buttoned device: comparison with first, second and third generation devices. International Buttoned Device Trial Group.

OBJECTIVES: The purpose of this study was to assess safety and effectiveness of the fourth generation buttoned device in dosing atrial septal defects (ASDs) and to test the hypothesis that introduction of double button reduces unbuttoning rate without reducing effectiveness. BACKGROUND: Because of the high unbuttoning rate (7.2%) with first, second and third generation buttoned devices, the device was modified (fourth generation) so that there were two radiopaque spring buttons 4 mm apart on the button loop attached to the occluder. METHODS: During a four-year period ending in September 1997, 423 patients, ages 1.5 to 80 years (median 16 years), underwent closure of ASD at 40 medical centers around the world. RESULTS: The ASD size varied between 5 and 30 mm (median 17 mm). The device size varied between 25 and 60 mm. Unbuttoning occurred in 4 (0.9%) of 423 patients. Effective occlusion, defined as no (n = 343) or trivial (n = 34) residual shunt on echo-Doppler studies performed within 24 h of the procedure, was demonstrated in 377 patients (90%). Thus, the unbuttoning rate (0.9 vs. 7.2%) decreased (p<0.01) while effective occlusion rate (90 vs. 92%) remained unchanged (p>0.1) with this device, compared with earlier generation devices. During follow-up from one month to five years (23+/-15 months), 21 (5%) of 417 patients required surgical (n = 12) or transcatheter (n = 9) reintervention, mostly to treat significant residual shunt. In the remaining patients there was gradual reduction and disappearance of the residual shunt. No wire integrity problems were observed. CONCLUSIONS: These data suggest that the fourth generation buttoned device is as effective as earlier generation devices, but without significant unbuttoning. Follow-up results remained good, with a reintervention-free rate of 89% at five years.

Adolescent↗

Pharmacological activities of Vitex agnus-castus extracts in vitro.

The pharmacological effects of ethanolic Vitex agnus-castus fruit-extracts (especially Ze 440) and various extract fractions of different polarities were evaluated both by radioligand binding studies and by superfusion experiments. A relative potent binding inhibition was observed for dopamine D2 and opioid (micro and kappa subtype) receptors with IC50 values of the native extract between 20 and 70 mg/mL. Binding, neither to the histamine H1, benzodiazepine and OFQ receptor, nor to the binding-site of the serotonin (5-HT) transporter, was significantly inhibited. The lipophilic fractions contained the diterpenes rotun-difuran and 6beta,7beta-diacetoxy-13-hydroxy-labda-8,14-dien . They exhibited inhibitory actions on dopamine D2 receptor binding. While binding inhibition to mu and kappa opioid receptors was most pronounced in lipophilic fractions, binding to delta opioid receptors was inhibited mainly by a aqueous fraction. Standardised Ze 440 extracts of different batches were of constant pharmacological quality according to their potential to inhibit the binding to D2 receptors. In superfusion experiments, the aqueous fraction of a methanolic extract inhibited the release of acetylcholine in a concentration-dependent manner. In addition, the potent D2 receptor antagonist spiperone antagonised the effect of the extract suggesting a dopaminergic action mediated by D2 receptor activation. Our results indicate a dopaminergic effect of Vitex agnus-castus extracts and suggest additional pharmacological actions via opioid receptors.

Animals↗

Quantitatively assessed coronary collateral circulation and restenosis following percutaneous revascularization.

AIMS: A high degree of collateral supply to a vascular area where a percutaneous transluminal coronary angioplasty (PTCA) has been performed represents a haemodynamic force competing with the antegrade flow through the dilated lesion. Therefore, our purpose was to determine whether patients with restenosis following PTCA have a higher collateral flow to the recipient vessel than patients without restenosis. METHODS AND RESULTS: In 200 consecutive PTCA patients, an intracoronary pressure-derived collateral flow index (CFI) was determined quantitatively during balloon occlusion, using simultaneous measurements of the mean aortic pressure (P(ao)) and of the intracoronary pressure distal to the occluded stenosis (P(occl)), as well as the estimated central venous pressure (CVP=5 mmHg): CFI=(P(occl)-CVP)/(P(ao)-CVP). Sixty-four patients had an angiographic follow-up examination after at least 2 months, and were subdivided into patients with restenosis (>50% diameter stenosis, n=34) and patients without restenosis (n=30). Patients with restenosis had a significantly higher collateral flow index at the initial coronary angiography than patients without restenosis (0.26 +/- 0.14 vs 0.12 +/- 0.09; P<0.0001). CONCLUSIONS: Patients with restenosis after PTCA show a more extended collateral supply to this recipient area than patients without restenosis. Well developed collaterals to a revascularized region are a risk factor for restenosis of the treated lesion.

Adult↗

Total occlusion trial with angioplasty by using laser guidewire. The TOTAL trial.

AIMS: A randomized trial was performed to assess the safety and efficacy of a laser guidewire, in the treatment of chronic coronary occlusions. METHODS AND RESULTS: In 18 European centres, 303 patients with a chronic coronary occlusion were randomized to treatment with either the laser guidewire (n=144) or conventional guidewires (mechanical guidewire, n=159). The primary end-point of the study was treatment success, defined as reaching the true lumen distal to the occlusion by the allocated wire within 30 min of fluoroscopic time: laser guidewire vs mechanical guidewire; 52.8% (n=76) vs 47.2% (n=75), P=0.33. Serious adverse events following the initial guidewire attempt were 0% (laser guidewire) and 0.6% (mechanical guidewire), respectively. Angioplasty (performed following successful guidewire crossing) was successful in 179 patients (91%, laser guidewire n=79, mechanical guidewire n=100), followed by stent implantation in 149 (79%). At the 6-month angiographic follow-up, the difference in binary restenosis rate (laser guidewire vs mechanical guidewire; 45.5% vs 38.3 %, P=0.72) or reocclusion rate (25.8% vs 16.1%, P=0.15) did not reach statistical significance. At 1, 6 and 12 months, angina and event-free survival were 69%, 35% and 24% (laser guidewire) vs 74%, 40% and 31% (mechanical guidewire). CONCLUSION: Although laser guidewire technology was safe, the increase in crossing success did not reach statistical significance.

Aged↗

Quantitative high performance liquid chromatographic analysis of diterpenoids in agni-casti fructus.

Pharmacological data have indicated that part of the dopaminergic activity of Vitex agnus-castus is attributed to the labdan diterpenoids found in the fruits. Therefore an analytical method for the standardization of rotundifuran (1), vitexilactone (2) and 6 beta,7 beta-diacetoxy-13-hydroxy-labda-8,14-diene (3) was developed. Because of the time-consuming and expensive isolation of the diterpenoids, p-cymene was chosen as an internal standard. The concentration of rotundifuran in different extracts and trade samples of the drug varies between 0.04 and 0.30% in the drug and between 1.04 and 2.23% in the extract. The concentration of vitexilactone was generally lower between 0.016 and 0.167% for the drug and between 0.34 and 1.01% for the extract. The determined concentration of 6 beta,7 beta-diacetoxy-13-hydroxy-labda-8,14-diene in the drug was in the range of 0.02 and 0.10% and in the extract in the range of 0.18 and 0.80%. Determination of the factors of correction of p-cymene gave 5.63 for rotundifuran, 2.73 for vitexilactone and 3.74 for 6 beta,7 beta-diacetoxy-13-hydroxy-labda-8,14-diene.

Chromatography, High Pressure Liquid↗

Surgical management of complications after transcatheter closure of an atrial septal defect or patent foramen ovale.

OBJECTIVE: During recent years, transcatheter closure has become an alternative to operations for the treatment of atrial septal defects and patent foramen ovale. However, this procedure may be unsuccessful or complicated and requires surgical treatment. METHODS: We retrospectively analyzed the outcomes of patients who needed surgical treatment after failed or complicated transcatheter closure of an atrial septal defect or a patent foramen ovale. RESULTS: Between April 1994 and March 1999, 124 patients were treated with transcatheter closure of an atrial septal defect or a patent foramen ovale at our institution. We report the results of 10 (8%) patients of this series who required operations after transcatheter closure attempts. In 8 of these 10 patients a significant shunt caused by malposition or dislocation of the device persisted, leading to surgical closure of the defect. In 2 patients injury of the femoral artery at the puncture site required surgical repair. In one patient the device had to be removed surgically from the iliac vein after retraction. One patient died of left ventricular perforation after dislocation of the device and several surgical attempts to close the left ventricular rupture. All other patients recovered well. CONCLUSION: An operation was required after transcatheter closure of an atrial septal defect or a patent foramen ovale in 8% of patients. After device complications, the atrial septal defect and the patent foramen ovale can still successfully be closed surgically with good results and low morbidity. However, serious complications like cardiac perforation may have a fatal outcome. Residual shunt, dislocation, or vascular complications are the most frequent problems that require surgical interventions.

Adolescent↗

Low reliability of perceptual priming: consequences for the interpretation of functional dissociations between explicit and implicit memory.

In this study, three experiments are presented that investigate the reliability of memory measures. In Experiment 1, the well-known dissociation between explicit (recall, recognition) and implicit memory (picture clarification) as a function of age in a sample of 335 persons aged between 65 and 95 was replicated. Test-retest reliability was significantly lower in implicit than in explicit measures. In Experiment 2, parallel-test reliabilities in a student sample confirmed the finding of Experiment 1. In Experiment 3, the reliability of cued recall and word stem completion was investigated. There were significant priming effects and a dissociation between explicit and implicit memory as a function of levels of processing. However, the reliability of implicit memory measures was again substantially lower than in explicit tests in all test conditions. As a consequence, differential reliabilities of direct and indirect memory tests should be considered as a possible determinant of dissociations between explicit and implicit memory as a function of experimental or quasi-experimental manipulations.

Adult↗

Tetrahydrobiopterin improves endothelial function in patients with coronary artery disease.

Tetrahydrobiopterin (BH4) is an essential cofactor for nitric oxide synthase (NOS) and a scavenger of oxygen-derived free radicals. Decreased availability of BH4 leads, under in vitro conditions, to reduced nitric oxide (NO) production and increased superoxide formation. We studied the effect of exogenous BH4 on endothelial function of angiographically normal vessel segments in patients with coronary artery disease. Nineteen patients with coronary artery disease underwent quantitative coronary angiography with simultaneous coronary flow velocity measurements (Cardiometrics FloWire). Data were obtained in angiographically normal segments of the left coronary artery at baseline, after intracoronary (i.c.) administration of acetylcholine (Ach; 10(-4) M), after infusion of BH4 (10(-2) M), and after co-infusion of ACh and BH4. At the end of the study, 300 microg nitroglycerin (NTG) i.c. was administered to obtain maximal vasodilation. At each step, flow velocity was determined before and after 18 microg adenosine i.c. to assess coronary flow velocity reserve. In 15 patients, ACh induced coronary vasoconstriction of -18 +/- 3% (endothelial dysfunction; p < 0.0001 vs. baseline), and in four patients, vasodilation of +39 +/- 20%. In the 15 patients with endothelial dysfunction, BH4 alone did not influence vessel area but prevented vasoconstriction to ACh (+2 +/- 3%, NS, vs. baseline). Correspondingly, calculated volume flow showed the highest value after co-infusion of ACh and BH4. Coronary flow velocity reserve was comparable during the various infusion steps. BH4 prevents ACh-induced vasoconstriction of angiographically normal vessels in patients with coronary artery disease. Thus substitution of this cofactor of NOS may represent a new approach for the treatment of endothelial dysfunction.

Acetylcholine↗

Systemic, pulmonary, and renal hemodynamic effects of endothelin ET(A/B)-receptor blockade in patients with maintained left ventricular function.

Endothelin-1 (ET-1) regulates vascular tone in congestive heart failure and modulates renal function. Its role in patients with normal left ventricular (LV) function and its renal effects are unclear. Cardiac and renal hemodynamics were studied in 24 patients with normal LV function and coronary arteries after single-dose, double-blind, randomized administration of TAK-044 (25, 50, or 100 mg, i.v.), an ET(A/B)-receptor antagonist, or placebo. Hemodynamics were monitored using Swan-Ganz and arterial catheters, and ET levels were measured. Renal function was assessed by clearance techniques. In the absence of a dose-response relation, TAK-044 patients were analyzed as a single group. Most hemodynamic effects occurred during the first 4 h. TAK-044 reduced mean arterial (-9.3 mm Hg, p < 0.001), pulmonary (-1.8 mm Hg, p = 0.01), and pulmonary capillary wedge pressure (-1.6 mm Hg, p < 0.001) between 30 min and 4 h. Mean reduction in systemic vascular resistance was 279 dyne/s/cm2 (p < 0.001), whereas heart rate increased 6.1 beats/min (p < 0.001) and cardiac index by 0.37 L/m2 (p = 0.01). Stroke volume index, right atrial pressure, and pulmonary vascular resistance did not change. TAK-044 increased renal plasma flow in proportion to the increase in cardiac output (+119 ml/min, 4 h after TAK-044; p < 0.05) and ET-1 levels (2.5-fold; p < 0.05). No serious side effects were noted. In patients with normal cardiac function, ET-receptor blockade causes vasodilation and reduces systemic but not pulmonary vascular resistance and increases cardiac index and renal plasma flow.

Aged↗

Angiographic documented coronary arterial spasm in absence of critical coronary artery stenoses in a patient with variant angina episodes during exercise and dobutamine stress echocardiography.

Dobutamine stress echocardiography is widely performed as a useful diagnostic tool in patients with known or suspected coronary artery disease. Dobutamine induced myocardial ischaemia is frequently associated with ST segment depression. ST segment elevation is uncommon and is almost always associated with prior myocardial infarction or transient total coronary occlusion. Dobutamine induced ST segment elevation in absence of significant coronary artery disease is a rare condition and is supposed to be a consequence of severe coronary artery spasm. The case of a 58 year old man with variant angina episodes at rest, during exercise test, and dobutamine stress echocardiography is reported, in whom coronary spasm without significant coronary artery stenoses was documented angiographically.

Angina Pectoris, Variant↗

A prospective randomized trial comparing stenting to internal mammary artery grafting for proximal, isolated de novo left anterior coronary artery stenosis: the SIMA trial. Stenting vs Internal Mammary Artery.

OBJECTIVE: To compare coronary artery bypass grafting (CABG) with percutaneous transluminal coronary angioplasty (PTCA) in patients with proximal, isolated de novo left anterior descending coronary artery disease and left ventricular ejection fraction of 45%. PATIENTS AND METHODS: In the multicenter Stenting vs Internal Mammary Artery (SIMA) study, patients were randomly assigned to PTCA and stent implantation or to CABG (using the internal mammary artery). The primary clinical composite end point was event-free survival, including death, myocardial infarction, and the need for additional revascularization. Secondary end points were functional class, antianginal treatment, and quality of life. Analyses were by intention to treat. RESULTS: Of 123 patients who accepted randomization, 59 underwent CABG, and 62 were treated with stent implantation (2 patients were excluded because of protocol violation). At a mean +/- SD follow-up of 2.4+/-0.9 years, a primary end point had occurred in 19 patients (31%) in the stent group and in 4 (7%) in the CABG group (P<.001). This significant difference in clinical outcome is due to a higher incidence of additional revascularization in the stent group, the incidence of death and myocardial infarction being similar (7% vs 7%, respectively; P=.90). The functional class, need for antianginal drug, and quality-of-life assessment showed no significant differences. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective treatments to relieve symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Both are associated with a low and comparable incidence of death and myocardial infarction. However, similar to PTCA alone, a percutaneous approach using elective stent placement remains hampered by a higher need for repeated intervention because of restenosis.

Adult↗

Transesophageal echocardiography to evaluate success of transcatheter closure of large secundum atrial septal defects in adults using the buttoned device.

OBJECTIVES: To determine the success rate of transcatheter closure of secundum atrial septal defects (ASDs) in adults and to characterize anatomical structures predisposing to unsatisfactory results. PATIENTS AND METHODS: Preinterventional and follow-up transesophageal echocardiography of 17 consecutive patients treated with a Sideris buttoned device was reviewed. Residual jet size of 5 mm or smaller was considered an adequate result; jet size larger than 5 mm was inadequate. Maximal ASD diameter, ASD area, and anterior, posterior, superior, and inferior septal rims were measured. RESULTS: The 7 patients with adequate results (41%) had smaller defects before implantation of a buttoned device (mean +/- SD maximal ASD diameter, 12 +/- 4 vs 19 +/- 5 mm; P<.005). Total rim length (mean +/- SD) was longer in patients with an adequate result (71 +/- 8 vs 46 +/- 11 mm; P<.001). The ASD size and length of the superior septal rim were independent predictors for an adequate result. Only 3 patients, all with ASD diameter less than 13 mm, had completely closed defects. All patients with ASD diameter greater than 20 mm had inadequate results and an unsatisfactory device position. The defect size (mean +/- SD) was similarly reduced in patients with adequate and inadequate results (9 +/- 3 vs 8 +/- 4 mm). CONCLUSION: Adults with a small ASD are more likely to have an adequate result after treatment with the buttoned device. A sufficiently large superior septal rim is particularly important for an adequate result. Most patients with a large ASD have inadequate results, although their ASD size is reduced by a similar absolute area as in patients with an adequate result.

Adolescent↗

Physiologically assessed coronary collateral flow and intracoronary growth factor concentrations in patients with 1- to 3-vessel coronary artery disease.

BACKGROUND: The purpose of this study was to test the hypothesis that there is a relation between collateral flow and intracoronary concentrations of basic fibroblast growth factor (bFGF) and vascular endothelial growth factor (VEGF) and that the combined concentrations of both growth factors and the extent of coronary artery disease (CAD) play a role as covariables in such an association. METHODS AND RESULTS: In 76 patients undergoing balloon angioplasty, a collateral flow index (CFI, no units) was determined with sensor-tipped guidewires. Simultaneously, serum concentrations of bFGF and VEGF, obtained at the aortic root from the ostium of the collateralized coronary artery (n = 76) and from the distal position of the occluded coronary artery (n = 34), were determined. There was a direct correlation between CFI and distal VEGF (r = 0.33, P = 0.05) but not bFGF concentrations. Focusing on the proximal sampling site, there was a direct correlation between CFI and both bFGF (r = 0.29, P = 0.01) and VEGF concentrations (r = 0.44, P < 0.0001). The sum of the concentrations of both growth factors was directly associated with CFI irrespective of the proximal (r = 0.51, P < 0.0001) or distal sampling site (r = 0.34, P = 0.048). There was a trend toward higher proximal VEGF concentrations in patients with higher numbers of coronary stenotic lesions (r = 0.25, P = 0.03). CONCLUSIONS: In patients with CAD, there is an association between a directly measured index of collateral flow and intracoronary concentrations of bFGF and VEGF. This direct relation is dependent on the site of blood sampling within the coronary artery tree. The association is closest when the combined bFGF and VEGF concentrations are taken into account. In the case of VEGF, it is influenced by the degree of coronary atherosclerosis.

Arteriosclerosis↗