Search PubMed⌕ Search

Biomedical subjects

B Maraviglia

Publications and source records attributed to B Maraviglia.

At least 37 records · Page 2Linked to original sources

Use of low-frequency electrical impedance measurements to determine phospholipid content in amniotic fluid.

In this report we propose a new method for an in vitro test of the foetal lung maturity based on the measurement of the electrical conductivity of the overall amniotic fluid obtained from transabdominal amniocentesis, since this quantity can be linked to a first approximation in a very simple way to the phospholipid content. We have carried out measurements of 85 different samples of amniotic fluid as a function of gestation weeks and we have observed a pronounced change of the electrical conductivity that reflects the increase in the phospholipid concentration occurring at the end of normal pregnancies. The method could be further developed to obtain similar information on in vivo experiments by means of bioelectric impedance tomography, taking advantage of the frequency dependence of the tissue electrical impedance.

Amniocentesis↗

In vivo 31P spectroscopy study of treated and untreated recovery of rat partial brain ischemia.

Quantitative 31P NMR was used to follow the time variation of the hypometabolic response to hypoxic partial ischemia in an animal model. The purpose of the study was to establish the value of this repeated spectroscopy operating by means of a surface coil. It aimed at determining whether a therapeutic intervention could influence the transient changes occurring during the insult or early recovery. A pharmacological substance was thus used during a reversible forebrain ischemia, induced by a combination of vascular occlusion and mild hypoxia in two groups of rats. As an available and convenient example, L-carnitine was chosen. Statistical analysis of the experimental results revealed a significant difference of the Pi and PCr levels between treated and untreated animals.

Adenosine Triphosphate↗

Alteration of the passive electrical properties of lymphocyte membranes induced by GM1 and GM3 glycolipids.

The electrical conductivity of normal human lymphocyte suspensions has been measured in the frequency range from 10 kHz to 100 MHz, where a well-pronounced conductivity dispersion occurs, caused by the surface polarization at the interface between the cell membrane and the extracellular solution. We have investigated the alteration of the passive electrical properties of the cytoplasmatic cell membrane induced by two different gangliosides (GM1 and GM3) inserted, at various concentrations, into the outer leaflet of membrane double layer. The alterations observed in the dielectric parameters (the membrane conductivity and the membrane permittivity) derived on the basis of a 'double-shell' model, result in an overall increase of the ion permeation across the membrane and an enhanced polarizability of its hydrophilic region for both gangliosides investigated. The relevance of these alterations is discussed.

Cell Membrane↗

Spin-lattice relaxation in murine tumors after in vivo treatment with interferon alpha/beta or tumor necrosis factor alpha.

1H NMR spin-lattice relaxation times (T1) were measured in vitro and in vivo in Friend leukemia cell tumors during subcutaneous tumor growth in syngeneic mice and after in vivo administration of either purified murine interferon alpha/beta (IFN) or recombinant tumor necrosis factor alpha (TNF). Untreated tumors exhibited monoexponential T1 relaxation independently of tumor age at least until Day 16 after implantation. Histological examinations showed that under these conditions tumors were highly homogeneous and substantially free of necrotic areas. Peritumoral administrations of either IFN or TNF did not significantly alter the tumor relaxation properties at early stages of inhibition of tumor growth. The longitudinal relaxation decay became instead clearly biexponential at later stages (more than 7 days of IFN treatment or 2 days after TNF administration). While the T1 relaxation behavior could be unequivocally correlated with the presence of necrotic areas in these tumors, it could not be considered as an early marker of the altered growth capability, induced by administration of either IFN or TNF.

Animals↗

Lee-Goldburg solid-state imaging.

A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science.

Magnetic Resonance Spectroscopy↗

Partial cerebral ischemia assessed by "in vivo" 31P NMR spectroscopy in rats.

31P NMR spectroscopy was used to assess the cerebral ischemia status in rats by measuring the relative levels of phosphate metabolites. Partial cerebral ischemia was induced in 49 rats by reversible occlusion of the carotid arteries. Rats were intubated and mechanically ventilated on a hypoxic gas mixture. Physiological parameters such as temperature and arterial pressure were strictly controlled during the experiments. 31P spectra were acquired at 7 T during basal observation, for 15-20 min after the induction of ischemia, and for 1 hr after reperfusion. Depletion and increase in PCr and Pi levels, respectively, were already observable in the collected spectra within few minutes after the onset of ischemia. No appreciable changes were found in the ATP levels.

Animals↗

Immiscible fluids permeability by T1 imaging.

Soil pollution by hydrocarbon compounds is an important part of the more general pollution problem. Some analogies with research problems encountered in studies of oil reservoirs in rocks suggested to us the opportunity to study the pollution dynamics by imaging the spatial distribution of the pollutant in a wet soil model by an NMR imaging technique. Some preliminary results using T1-weighted imaging are reported here.

Magnetic Resonance Spectroscopy↗

Study of proton spin-lattice relaxation variation induced by paramagnetic antibodies.

A murine anti-human melanoma monoclonal antibody fragment was labeled with gadolinium and its proton relaxation efficiency compared to controls at frequencies ranging from 2 to 300 MHz. Relaxation time variations were about 30-40% in 10-15 microM solutions. The labeled fragment showed proton relaxation enhancement relative to free gadolinium, while preserving its immunoreactivity. A tentative labeling of a melanoma pellet by means of the fragment, just at the borderline of a minimum expected T1 variation, gave no detectable difference.

Animals↗

Maximum entropy and 2DFT NMR images.

A comparison between contrast and signal-to-noise ratio (SNR), as obtained by both maximum entropy (ME) and 2DFT reconstruction, is reported for NMR images. Our results show that in the ME elaboration the contrast and SNR are generally increased with respect to the 2DFT elaboration. The magnitude of such an increase depends on the ME statistical parameter and also, quite strongly, on the values of contrast and SNR of the 2DFT image.

Magnetic Resonance Imaging↗

Biological tissue simulation and standard testing material for MRI.

The polyacrylamide gel is proposed here as a phantom material for NMR imaging. This substance has electrical and NMR relaxation characteristics very similar to those of biological tissues. The thermal and time stabilities also make this material a convenient standard for MRI.

Acrylic Resins↗

Modified crossed-ellipse radiofrequency coil for MRI.

New coil geometries obtained by computer simulations from the crossed-ellipse rf coil are reported. These geometries with elliptical transverse section improve the signal-to-noise ratio with respect to the classic ellipse and saddle coils. The increase of signal-to-noise ratio is mainly due to the reduction of coil losses and to the better B1 efficiency and distribution.

Abdomen↗

Human erythrocyte membranes are fluid down to -5 degrees C.

This first observation of the deuterium nuclear magnetic resonance (2H-NMR) spectrum of phospholipid molecules incorporated into intact human erythrocyte ghosts shows that the liquid crystalline phase is stable down to a temperature of -5 degrees C. The quality of the 3H-NMR spectra indicate that it is now possible to carry out clinical studies of erythrocyte membranes using the techniques employed in this study.

Erythrocyte Membrane↗

Role of 3D imaging in small scale NMR tomography.

Some advantages of using 3D techniques in small scale NMR imaging are suggested. In particular the 3D methods are likely to be useful in slow dynamical processes occurring in vivo. Three-dimensional images obtained with our first home built prototype are also reported.

Animals↗