Stent coating with titanium-nitride-oxide for reduction of neointimal hyperplasia.

BACKGROUND: Coronary stents prevent constrictive arterial remodeling but stimulate neointimal hyperplasia. Stainless steel induces a metallic foreign body reaction, which is absent for titanium. The hypothesis of the present study was that titanium renders the stent surface biologically inert, with reduced platelet and fibrinogen binding. METHODS AND RESULTS: Twelve pigs were instrumented with a stainless steel and 2 titanium-nitride-oxide-coated stents (TiNOX 1, ceramic; TiNOX 2, metallic). Animals were restudied after 6 weeks. Histological specimens of stented segments were analyzed by digital morphometry. Platelet adhesion and fibrinogen binding studies were performed in the perfusion chamber. Under in vitro conditions, TiNOX 1 showed reduced platelet adhesion (65+/-3%) compared with TiNOX 2 (72+/-5%; P<0.05) and stainless steel (71+/-4%; P<0.05). Platelet adhesion 48 hours after incubation with human plasma, however, was not different between TiNOX 1 (17+/-3%) and 2 (15+/-3%) but was significantly higher with stainless steel (23+/-2%; P<0.05). Fibrinogen binding was significantly reduced with TiNOX 2 (54+/-3%) compared with TiNOX 1 (82+/-4%, P<0.05) or stainless steel (100%, P<0.05). Histomorphometry revealed a significantly larger neointimal area in stainless steel (2.61+/-1.12 mm(2)) than in TiNOX 1-coated (1.47+/-0.84 mm(2), P<0.02) or TiNOX 2-coated (1.39+/-0.93 mm(2), P<0.02) stents. The reductions were 44% and 47%, respectively. CONCLUSIONS: TiNOX coating significantly reduces neointimal hyperplasia in stainless steel stents. The antiproliferative effect was similar for both TiNOX coatings, suggesting that the electrochemical properties are more important for attenuation of neointimal proliferation than the observed differences in platelet adhesion and fibrinogen binding.

Alloys↗

Uterine electrical activity as predictor of preterm birth in women with preterm contractions.

OBJECTIVE: To estimate the risk of preterm birth in women admitted to the tertiary maternity hospital for preterm contractions by measuring electrical uterine activity. STUDY DESIGN: The study included 47 patients with contractions between the 25th and 35th week of gestation and additional risk factors for preterm delivery. Uterine electrical activity was recorded using bipolar electrodes placed on the abdominal surface. A logistic model with the electromyographic and obstetric data was built, preterm delivery before 37th week of gestation being the outcome measure. RESULTS: Seventeen patients (36%) delivered before term. Logistic regression model suggested only the intensity of electrical uterine activity and woman's body weight to be significant predictors of preterm delivery, with high values related to preterm birth. They predict preterm delivery with the sensitivity of 47% and specificity of 90%. CONCLUSION: We propose uterine EMG as a simple, non-invasive means to estimate the risk of preterm birth in a high-risk population with multiple risk factors present.

Electromyography↗

Optimization of venous return tubing diameter for cardiopulmonary bypass.

OBJECTIVE: To determine the optimal venous tubing diameter for adult cardiopulmonary bypass (CPB) to improve gravity drainage and to reduce priming volume. METHODS: (A) Maximum bovine blood flow rates by gravity drainage were assessed in vitro for four different tubing diameters (1/2, 3/8, 5/16,1/4 inch) with three different lengths and various pre- and afterloads. Based on the results of (A) and multiple regression analyses, we developed equations to predict tubing sizes as a function of target flows. (C) The equations obtained in (B) were validated by ex vivo bovine experiments. (D) The clinically required maximal flows were determined retrospectively by reviewing 119 perfusion records at Zurich University. (E) Based on our model (B), the clinical patient and hardware requirements, the optimal venous tubing diameter was calculated. (F) The optimized venous tubing was evaluated in a prospective clinical trial involving 312 patients in Hangzhou. RESULTS: For a mean body surface area of 1.83+/-0.2 m(2), the maximal perfusion flow rate (D) achieved with 1/2-inch (=1.27 cm(2)) venous tubing was 4.62+/-0.57 l/min (range: 2.50-6.24 l/min). Our validated model (B,C) predicted 1.0 cm(2) as optimal cross-sectional area for the venous line. New tubing packs developed accordingly were used routinely thereafter. The maximal flow rate was 4.93+/-0.58 l/min (range: 3.9-7.0) in patients with a mean body surface area of 1.62+/-0.21 m(2). CONCLUSION: The new venous tubing with 1.0-cm(2) cross-sectional area improves the drainage in the vast majority of adult patients undergoing CPB and reduces the priming volume (-27 ml/m). Reduced hemodilution can prevent homologous transfusions if a predefined transfusion trigger level is not reached.

Adult↗

Contribution of cervical smooth muscle activity to the duration of latent and active phases of labour.

OBJECTIVE: To identify the effect of cervical muscle activity as an additional factor influencing the duration of the latent and active phase of labour. DESIGN: Prospective observational study. SETTING: The Ljubljana Maternity Hospital. PARTICIPANTS: Fifty healthy nulliparous women requiring induction of labour having relatively unripe cervices. METHODS: At the onset of labour an open-ended catheter was inserted to measure intrauterine pressure during the latent and active phase of labour. Electromyographic activity of the cervix was registered by two bipolar spiral needle electrodes placed in the transverse direction on the proximal part of the cervix in the vagina. The mean intensity of distinctive peaks in an electromyographic spectrogram were calculated in the time/frequency domain. Multiple linear regression was used to find factors affecting the duration of the latent and active phase of labour. MAIN OUTCOME MEASURES: Duration of the latent and active phase of labour. RESULTS: Eleven independent variables explained 64% of the variance of the latent phase duration, the most important being the effacement and consistency of the cervix, and intensity of electromyographic signals. For the duration of the active phase the same variables explained 36% of the variance; the most important variables were mean duration of uterine contractions, mean maximum intensity of uterine contractions and the newborn's head circumference. CONCLUSIONS: The cervical smooth muscle activity, expressed as an electromyographic signal, contributes to the duration of the latent phase but not to the duration of the active phase. However, frequent cervical contractions are not associated with a longer latent phase.

Birth Weight↗

Affinity pump system: a new peristaltic blood pump for cardiopulmonary bypass.

An in vitro study has been carried out to assess the pump performance of a new peristaltic, extracorporeal displacement pump (Affinity) for cardiopulmonary bypass. The pump system consists of a pump rotor (0-110 rpm), a pump chamber, a venous reservoir with a 5/8" connecting tube and the Affinity console. The polyurethane chamber is connected to the venous reservoir by a 5/8" tube and fills passively due to the hydrostatic pressure exhibited by the fluid height in the venous reservoir. The implementation of an occlusive segment in the pump chamber, which collapses in low filling states, should prevent significant negative pressures. An in vitro circuit was filled with bovine blood (37 degrees C, hematocrit 35%) and the pump flow was measured by an ultrasonic transit time flow probe with respect to pre-load, diameter and length of attached tubing in the venous line, pump speed (rpm) and size of the connecting tube (3/8" and 5/8"). At 108 rpm and a preload equal to 10 mmHg, the flow was 8.6 +/- 0.42 l/min for an afterload of 80 mmHg. The reduction of the inlet connector to 3/8" diminished the pump flow significantly to 5.2 +/- 0.31 l/min (p < 0.0001). The pump flow decreased linearly with respect to the length of the attached tube in the venous line and for a 2 m long 5/8" silicon tube, the rpm-optimized flow was still 6.0 +/- 0.28 l/min at a preload of 10 mmHg. In case of low filling state or too high rpm, the occlusive segment collapsed and no cavitation bubbles could be detected. Our in vitro measurements yield a nomogram for rpm-optimized blood flow with respect to the pre-load in the venous reservoir. The delivered 5/8"connecting tube facilitates optimum filling of the pump chamber for high blood flow, but limits the use of venous reservoirs to Affinity products. The pump yields a high blood flow even when long tubing in the venous line is used. This makes the pump a candidate for a ventricular assist device. In hypovolemia or high rpm, the occlusive segment collapses and no negative pressure is generated at the inflow site of the pump chamber.

Animals↗

Flow measurements through aortocoronary and intraluminal coronary shunts.

AIMS: Temporary insertion of shunts during coronary artery bypass grafting (CABG) on the beating heart may provide the minimal flow required for adequate myocardial protection (40 to 60 ml/min). We investigated the flow as a function of the pressure head over three aortocoronary shunts and one intraluminal coronary shunt. METHODS: The aortocoronary shunts (VS-01590 with bulb size 2, 3 and 4 mm) and the intraluminal shunt (IVS-4030, bulb size 4 mm) were perfused with 47% glycerin solution at 37 degrees C. The preload was raised in 5 mmHg steps from 35 to 80 mmHg. The afterload was set at 12 mmHg. A regression analysis of the flow on the pressure head was performed. RESULTS: For maximal preload the flow through the aortocoronary shunts was 15.9 +/- 1.3, 46.2 +/- 2.2 and 75.4 +/- 3.3 ml/min, for the intraluminal shunt it was 76.1 +/- 3.4 ml/min. To provide a flow of 40 ml/min a preload of 70, 50 and 45 mmHg was necessary for the 3 mm and 4 mm aortocoronary shunt and the intraluminal shunt respectively. For the aortocoronary and the intraluminal shunts the beta-coefficients were 0.27, 0.66, 1.13 and 1.02 ml/(min*mmHg) respectively with all p < 0.0001. CONCLUSIONS: For adequate pressure head the 3 mm and 4 mm aortocoronary shunt and the intraluminal shunt provide myocardial protection. In case of severe proximal coronary stenosis the intraluminal shunt will not guarantee myocardial protection and main benefit reduces to working in a bloodless field. The insertion of shunts is a cheap and simple method to optimize CABG on the beating heart.

Arteriovenous Shunt, Surgical↗

Electromyographic activity of the uterus above the placental implantation site.

The aim of this study was to evaluate the electromyographic (EMG) activity of the uterus concerning the placental implantation site. In a clinical trial, 55 pregnant women in the last trimester of pregnancy were enrolled. They were divided into two major groups: 25 women had placental implantation site on the anterior and 30 women on the posterior uterine wall. With regard to the presence/nonpresence of contractions, each group was further divided into two subgroups. Uterine EMG activity was recorded by electrodes placed on the abdominal wall. All signals were transferred through a series of amplifiers. Amplified and filtered EMG signals were digitized and written on a hard disk, simultaneously with the signals of external tocodynamometry. From the 30-min EMG recording, we calculated the average root mean square (RMS) and the average median frequency (MF) of the signal. A significant difference of the abdominal EMG activity concerning the placental implantation site was found only in pregnant women with contractions. The RMS was significantly lower in the placental implantation site on the anterior uterine wall, whereas the MF was significantly higher. It can be concluded that the placental implantation site influences the uterine EMG activity registered through the abdominal wall, especially when registered above the placental implantation site.

Electromyography↗

Optimized performance of the Abiomed BVS 5000: adjustment of the pump height based on Doppler control of the flow pattern.

The Abiomed BVS 5000 is an automatic volume-driven paracorporeal pulsatile assist device providing left, right or biventricular support. The paracorporeal position allows optical adjustment of filling volumes of the device, which determines the output of the system. A procedure to adjust for maximal stable flow has not yet been established. In vitro measurements have been performed to assess the flow and pressure characteristics of the Abiomed BVS 5000 by raising the preload in 5 mmHg steps before running the system. Doppler probes were placed at the inflow and outflow lines of the pump. After setting the afterload at 80 mmHg the assist device was started. Two measurements were performed to find optimal flow (based on Doppler control and optical adjustment). (1) By Doppler control a stable flow pattern was found at a preload of 25 mmHg with a mean atrial pressure of 5 mmHg and a mean flow of 5.3 +/- 0.7 l/min (mean +/- standard deviation) at the inflow and outflow sites (the console flow was 4.8 +/- 0.4 l/min with a frequency of 61.8 +/- 2.0 l/min). (2) Optical adjustment of the pump height gave rise to a preload of 35 mmHg where we recorded a maximal atrial pressure of 107 +/- 5.8 mmHg, a maximal retrograde flow of -4.3 +/- 1.2 l/min at the inflow and -1.2 +/- 0.4 l/min at the outflow site. The mean flow at the inflow and outflow sites was 5.1 +/- 0.5 l/min (the console flow was 4.6 +/- 0.3 l/min with a frequency of 59.6 +/- 2.6 Hz). At an initial afterload of 60 and 40 mmHg the system showed the same qualitative behaviour, but the results were less accurate. Optical adjustment of the pump height may result in an atrioventricular valve insufficiency with undetected retrograde flow and high atrial pressures. We conclude that a Doppler flow probe must be placed at the inflow site to guarantee maximal stable flow.

Equipment Design↗

Hemodynamic properties of the hemopump HP14.

BACKGROUND: The Hemopump HP14 is a catheter-mounted, transvalvular, left ventricular assist device intended for femoral percutaneous insertion. The pump was developed for patients with postoperative or postinterventional low cardiac output and for CABG surgery on the beating heart. Little is known about the effect of afterload and hematocrit on the pump performance. METHODS: The influence of hematocrit and afterload on the pump flow was tested using an in vitro model filled with heparinized bovine blood. Regression analysis of the pump flow with respect to three hematocrit values (20%, 30%, 40%) and ten afterload levels (30 mmHg-120 mmHg in 10 mmHg increments) was performed for all pump speed levels (n = 7). RESULTS: At all pump speed levels reduction of afterload and hematocrit were significant predictors for increasing pump flow (p<0.001). For hematocrit values between 40% and 20% and highest pump speed, mean pump flow at lowest afterload ranged between 2.34 and 2.53 L/min; and at highest afterload between 1.31 and 1.53 L/min. For speed level 1, afterload of 120 mmHg and hematocrit of 40% there was a maximal retrograde flow of 230+/-35 ml/min. CONCLUSIONS: Pump performance is significantly improved by both afterload and hematocrit reduction. In the weaning phase and during the removal of the device, the pump should run at a speed level of at least three to prevent retrograde flow in the pump. Estimates for pump flow in vivo can be extrapolated from our diagrams. Our results show that the Hemopump HP14 is a valuable alternative to intra-aortic balloon counterpulsation.

Animals↗

Activity of smooth muscles in human cervix and uterus.

OBJECTIVE: To find the similarities and dissimilarities between the activity of the human smooth muscles in the cervix and in the uterine corpus at the onset of induced labour. STUDY DESIGN: Electromyographic activity was measured in 14 primiparous women after amniotomy. The data were sampled and stored digitally in real time. For statistical analysis, the first 20 min of recordings following amniotomy were analyzed. The ratio between the mean activity at a given time and the mean activity over the whole 20 min was used for the comparison between the cervical and uterine activity. RESULTS: The analysis of correlation showed that the electromyographic activity in the cervix differed from that in the uterine corpus in the majority of the enrolled cases. CONCLUSIONS: The muscular activity in the cervix is independent of that in the uterine corpus at the onset of induced labour.

Cervix Uteri↗

Biventricular assist using a portable driver in combination with implanted devices: preliminary experience.

Left ventricular assist systems with portable drive units are increasingly used in the clinical setting. However, such systems usually are not suitable for right ventricular support, and therefore, in the case of biventricular heart failure, they must be combined with other support devices that require additional drive consoles. As a result, most of the benefits of the wearable drive units (early mobilization and outpatient care) are lost. This present study was performed to evaluate biventricular support with implanted assist devices and a portable DC/battery-powered driver (Thoratec TLC-II). Electronic control by nonvolatile RAM accessible via RS232 interface, internal backup emergency battery, and optional manual activation are additional features of this 6 kg biventricular drive unit. In 3 bovine experiments (body weight 70 +/- 5 kg) partial cardiopulmonary bypass (CPB) was established, and two ventricular assist devices were implanted into a preperitoneal pocket on each side after connection to the right atrium and the pulmonary artery and to the left atrium and aorta, respectively. After weaning the patient from CPB, activated coagulation time (ACT) was kept at greater than 180 s, and biventricular support with the portable driver was activated. After 10 min, mean device flow stabilized at 3.5 +/- 0 L/min and remained at that level throughout the ensuing 6 h (3.5 +/- 0.3 L/min; NS). The heart rate moved from 130 +/- 13 beats per minute (bpm) at the end of CPB to 116 +/- 13 bpm after 10 min of assist (p < 0.05). Right atrial pressure moved from 11 +/- 2 mm Hg at the end of CPB to 13 +/- 3 mm Hg after 10 min of assist (not significant [NS]). Mean pulmonary artery pressure was 18 +/- mm Hg at the end of CPB and 17 +/- 5 mm Hg after 10 min of assist (NS). Left atrial pressure was 10 +/- 1 mm Hg at the end of CPB and 13 +/- 3 mm Hg after 10 min of assist (NS). Mean aortic pressure was 73 +/- 11 mm Hg at the end of CPB and 77 +/- 3 mm Hg after 10 min of assist (NS). Mixed venous oxygen saturation increased from 49 +/- 9% at the end of CPB to 58 +/- 10% after 10 min of assist (p < 0.05). The portable drive unit that was tested provides adequate power to maintain significant biventricular support with implanted right and left assist devices. The configuration of batteries tested driving two ventricles provides independence for 60 min.

Animals↗

Effect of intermittent warm blood cardioplegia on functional recovery after prolonged cardiac arrest.

BACKGROUND: There is some evidence that continuous warm blood cardioplegia offers good myocardial protection; however, the effects of interrupting cardioplegia remain controversial. To study this, we compared the effects of continuous and intermittent antegrade warm (37 degrees C) blood cardioplegia on functional recovery after prolonged cardiac arrest (180 minutes). METHODS: Twenty-four juvenile pigs were randomly assigned into four groups. Group 1 received continuous cardioplegia, group 2 underwent several periods of 15 minutes of cardioplegia interrupted by 5 minutes of normothermic ischemia, and group 3 underwent several periods of 10 minutes of cardioplegia interrupted by episodes of 10 minutes. The hearts of group 4 received no cardioplegia. Left ventricular systolic function was assessed from fractional left ventricular shortening and percentage left ventricular wall thickening, and left ventricular diastolic function was determined from the time constant of relaxation and the constant of myocardial stiffness. RESULTS: Systolic and diastolic functions were slightly depressed 1 and 2 hours after cross-clamp removal in all four groups, without significant differences among the groups. CONCLUSIONS: These data suggest that antegrade warm blood cardioplegia can be interrupted for up to 10 minutes without obvious negative effects on left ventricular function in the normal myocardium, provided that the intermittent doses of cardioplegia are sufficient to restore the metabolic demands of the arrested myocardium.

Animals↗

[Thrombosis-resistant heparin-coated diffusion membrane oxygenators: an experimental study].

In the present study the thromboresistance of heparin-coated diffusion membrane oxygenators (Jostra, M 30) combined with heparin-coated venous reservoirs, tubing sets and arterial filters was investigated in six bovine experiments (70 +/- 5 kg). The perfusion with reduced systemic heparin dose (100 IE/kg) body weight) was performed with activated clotting time over 180 seconds. The perfusion began with a blood flow of 31/min and was maintained during six hours. Clotting studies including blood platelet count, activated clotting time, fibrinogen (factor I), antithrombin III and fibrinopeptid A were performed before the operation and ten minutes, two hours and five and six hours after beginning of bypass. The venous and arterial saturation remained stable during the whole investigation. After ten minutes activated clotting time dropped from 619 +/- 114s to 203 +/- 15s after six hours (p < 0.05). The antithrombin III level changed significantly from 109 +/- 11% to 95 +/- 16%. Factor 1 and fibrinopeptid A changes were not significant: from 1.6 +/- 0.3 g/1 to 1.5 +/- 0.3 g/1, and 3.0 +/- 1.4 ng/mL to 3.5 +/- 1.2 ng/mL, accordingly. There were no mechanical defects and especially no plasma leakage. Slight sediments were found only in areas of stagnant blood flow. The investigated bypass circuit with reduced systemic heparinization seems therefore particularly appropriate for long-term perfusions.

Animals↗

Influence of hemodynamics on the performances of intravascular gas exchangers.

BACKGROUND: The intravascular gas exchanger is a lung assist device for augmentation of gas exchange in critically ill patients with severe acute respiratory failure. These patients often require inotropic support therapy due to the cardiovascular instability that almost inevitably accompanies severe respiratory failure. METHODS: We investigated the interaction of vasoactive medication (dopamine, nitroglycerin, and noradrenaline) with the gas exchange performances of the intravascular gas exchanger in a bovine experimental model. RESULTS: Dopamine administration highly increased cardiac output, caval flow rates, and diameter of vena cava inferior. These effects resulted in a significant increase in oxygen transfer (baseline, 35 +/- 6 mL/min versus 153 +/- 27 mL/min at 20 micrograms.kg-1.min-1 of dopamine, p < 0.001) and carbon dioxide elimination (baseline, 35 +/- 2 mL/min versus 47 +/- 4 mL/min at 20 micrograms.kg-1.min-1 of dopamine, p < 0.001). Administration of nitroglycerin did not cause significant changes of the hemodynamic parameters nor did it affect the oxygen transfer or carbon dioxide elimination. Noradrenaline caused a moderate increase in cardiac output and caval flow, but no changes of caval diameter. hemodynamic changes were accompanied by an increase in oxygen transfer from 38 +/- 5 mL/min to 68 +/- 7 mL/min (p < 0.01) and carbon dioxide elimination from 33 +/- 1 mL/min to 40 +/- 1 mL/min (p = 0.03). The multiple regression analysis showed significant influence of changes in cardiac output on oxygen transfer (p < 0.001) and carbon dioxide elimination (p = 0.004). The administration of vasoactive drugs induced slight changes in caval diameter that did not significantly affect the gas transfer. CONCLUSIONS: The results from our study reveal the major influence of cardiac output on efficiency of gas transfer of the intravascular oxygenator.

Animals↗

Continuous versus bolus thermodilution cardiac output measurements--a comparative study.

OBJECTIVE: To compare the methods for continuous and bolus thermodilution cardiac output measurements. DESIGN: In vivo and in vitro experimental studies. SETTING: Surgical research division in a university hospital. SUBJECTS: Eight calves and flow bench model. INTERVENTIONS: Data were collected in vivo from eight calves instrumented with pulmonary artery catheters, which allowed both continuous and bolus thermodilution measurements. The pulmonary artery catheter was placed through the external jugular vein. All in vitro measurements were performed using a flow bench model. MEASUREMENTS AND MAIN RESULTS: A total of 232 bolus and continuous thermodilution measurements were analysed in vivo to determine the degree of agreement between the two methods. The absolute measurement bias was 0.14 L/min with 95% confidence limits ranging from -0.83 to 1.15 L/min. In vitro analysis of 576 measurements at six different temperature points (range 31 degrees to 41 degrees C), using clinically relevant flows (2 to 9 L/min), showed overestimation of flow values using continuous and bolus thermodilution methods. However, the continuous method showed better accuracy by a lower degree of overestimation. Systematic error was 9.7 +/- 8.4 (SD) % for continuous and 11.1 +/- 6.3% for the bolus method (p < .001). This effect was especially evident at lower flow rates. The influence of various temperatures on the accuracy and reproducibility of both methods of measurement was statistically significant but not clinically relevant. The infusion of lactated Ringer's lactate solution (infusion rates 100 to 1000 mL/hr) affects both methods at a low flow rate of 2 L/min, without causing a significant effect on continuous measurement at a higher flow rate (4 L/min). Shunting of 50% of circulating volume to the distal part of the thermal filament of the pulmonary catheter impaired the accuracy of continuous measurement without affecting results from bolus measurements (systematic error -26.8 +/- 8.2% for continuous and -5.2 +/- 4.1% for bolus thermodilution). CONCLUSIONS: Continuous thermodilution cardiac output measurement provided higher accuracy and greater resistance to thermal noise than standard bolus measurements. The correct placement of the catheter is essential for precise measurements.

Analysis of Variance↗

Quantitative gas transfer of an intravascular oxygenator.

The intravascular oxygenator is a newly developed device for intracaval gas exchange in critically ill patients with respiratory failure. In an experimental ex vivo model, performance characteristics of the intravascular oxygenator/carbon dioxide removal device were studied. With a mean hemoglobin concentration of 6.2 +/- 1.9 g/dL (mean +/- standard deviation), total O2 transfer was 21.8 +/- 4.8 mL/min at a blood flow of 1 L/min, 37.0 +/- 12.6 mL/min at 2 L/min, at 2 L/min, and 47.5 +/- 16.7 mL/min at 3 L/min. Total CO2 transfer was 27.3 +/- 6.6 mL/min at a blood flow of 1 L/min, 38.6 +/- 8.9 mL/min at 2 L/min, and 40.4 +/- 9.3 mL/min at 3 L/min. In contrast to total gas transfer, O2/CO2 transfer rates (mL/L) diminished significantly with increasing blood flow. In addition, there was a negative correlation between O2 transfer rate and venous O2 partial pressure (r = -0.73; p < 0.0001), a positive correlation between CO2 transfer rate and venous CO2 partial pressure (r = 0.65; p < 0.0001), and a positive correlation between O2 and CO2 transfer rates and blood hemoglobin level (r = 0.57 [p < 0.01] and r = 0.70 [p < 0.01], respectively). These results demonstrate that the behavior of the intravascular hollow-fiber oxygenator is similar to that of the classic membrane oxygenator used for cardiopulmonary bypass: total gas transfer correlates directly with blood flow and venous CO2 partial pressure and indirectly with venous O2 partial pressure. The O2 and CO2 transfer rates increase significantly with increasing hemoglobin content of the blood.

Animals↗

Treatment of acute pulmonary hypertension with inhaled nitric oxide.

We examined the effectiveness of inhaled nitric oxide (NO) as a selective pulmonary vasodilator in acute pulmonary hypertension in an in vivo canine model with fixed cardiac output. In 5 dogs, total right heart bypass was instituted, and pulmonary hypertension was induced by infusion of the thromboxane analogue U-46619. During U-46619 infusion, NO was administered at 10 and 40 ppm for 5 minutes followed by breathing of the oxygen mixture without NO. Pump flow was held constant during the experiment. Infusion of the thromboxane analogue resulted in an increase in pulmonary vascular resistance and systemic vascular resistance from 147 +/- 83 to 740 +/- 126 dyne.s.cm-5 and from 1,720 +/- 113 to 2,407 +/- 232 dyne.s.cm-5, respectively. During inhalation of 10 ppm NO, pulmonary vascular resistance significantly decreased to 613 +/- 55 dyne.s.cm-5 (p < 0.05) and further decreased to 527 +/- 163 dyne.s.cm-5 with 40 ppm NO inhalation (p < 0.05). Systemic vascular resistance did not change during NO treatment (2,300 +/- 70 dyne.s.cm-5 during 40 ppm NO). There was no increase in intrapulmonary shunting or methemoglobin levels during NO inhalation. In this setting, with a constant cardiac output throughout the experiment, NO acted as a selective pulmonary vasodilator without altering systemic vascular resistance. However, induced pulmonary vasoconstriction was only partially reversed by NO inhalation.

Acute Disease↗