Search PubMed⌕ Search

Biomedical subjects

B Lachenmayr

Publications and source records attributed to B Lachenmayr.

31 records · Page 2Linked to original sources

Fate of late complications in type I diabetic patients after successful pancreas-kidney transplantation.

The success rate of pancreas transplantation allows us to study in more detail the potential beneficial effects of normoglycemia on secondary complications in diabetes mellitus. We report a prospective follow-up (mean 26 mo) of metabolic control, neuropathy, retinopathy, and peripheral microcirculation in 31 patients with type I (insulin-dependent) diabetes (mean age 33 +/- 1 yr; mean duration of diabetes 21 +/- 1 yr) after combined kidney and segmental pancreas grafting. All patients had normal HbA1 levels. Glucose tolerance (GT), insulin, C-peptide, and glucagon were normal in 22 patients, and impaired oral GT with reduced insulin secretory capacity was seen in 9 patients. During follow-up, there was no deterioration of GT and insulin release. Vascular risk factors, e.g., hypertension, cholesterol, and triglycerides, decreased after grafting. Autonomic neuropathy improved clinically, and R-R variation increased significantly in 3 of 18 patients. Peripheral neuropathy improved clinically in 46% of patients and did not deteriorate in the others. Motor nerve conduction velocity increased greater than 20% in 8, less than 20% in 12, and was unchanged in 8 of 28 recipients. Most of the patients (n = 30) had pretransplant laser treatment of their advanced retinopathy. Posttransplant visual acuity improved at least more than one line in 56%, stabilized in 32%, and deteriorated in 12% of patients. Patients with functioning grafts for greater than 1 yr had no further deterioration of visual acuity. Vitreous hemorrhage frequency and severity dropped markedly from pretransplant (from 69 to 24%) 10 mo after grafting. Retinal morphology remained stable in all eyes except two.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Automated flicker perimetry].

Flicker fusion frequency (FFF), the threshold criterion of flicker perimetry, is a functional parameter of the temporal transfer properties of the visual system. An automated flicker perimeter suitable for clinical routine purposes is presented that allows perimetric examination of the central visual field with high spatial resolution. The intent of the present study was to investigate the outcome of flicker perimetry in comparison to static light-sense perimetry. In the majority of cases of ocular hypertension and suspected glaucoma (n = 31), chronic open-angle glaucoma (n = 36) and acute neuritis/papillitis (n = 10) defects are indicated by flicker perimetry in areas of the visual field with normal light sensitivity according to static light-sense perimetry (Octopus 201, program G 1). In many cases of preproliferative diabetic retinopathy (n = 10), however, flicker perimetry indicates fewer defects than static perimetry (Octopus 201, program 32). The results collected up to now suggest that automated flicker perimetry might represent a specific functional test of the retinal Y-ganglion cells.

Diabetic Retinopathy↗

[Perimetry yesterday and today].

The historical development of perimetry, from the first technical devices for testing the visual field (arc perimeter) through the manual hemispherical perimeters (Tübingen and Goldmann perimeters) to the latest developments in automated, computer-controlled perimeters, is described with reference to the basic measuring methods and strategies on the one hand and technical realization on the other. The future development of perimetry will be characterized by a refinement of measured value statistics and the testing of perimetric procedures that test more complex physiological functions than sensitivity to differences (e.g., analysis of temporal transmission characteristics in flicker perimetry.

Europe↗

[Study of early glaucomatous visual field defects with the automatic perimeter Topcon SBP-1000. Comparative study with the Octopus 201 perimeter].

The automatic perimeter TOPCON SBP-1000 uses light emitting diodes (LED's) for stimulus generation and thus completely differs from the projection type perimeter OCTOPUS 201. In order to get some first idea about the capabilities of the TOPCON SBP-1000 22 eyes of 18 patients with early glaucomatous visual field defects were examined both with the glaucoma program/TOPCON SBP-1000 and program 31/OCTOPUS 201. Field defects were divided into three groups according to the total loss (program DELTA/OCTOPUS 201): group I with a total loss of 0 dB, group II with a total loss of 1-200 dB, group III with a total loss greater than 200 dB. Evaluation and comparison of visual field results is done after discussing the most important technical parameters and fundamental aspects of methods and strategies using the total percentage of "normal" test points, "small relative defects", "deep relative defects" and "absolute defects". We could show that specificity and sensitivity for the detection of earliest field defects are quite equal both in the TOPCON SBP-1000 and in the OCTOPUS 201. Concerning the detection of more pronounced visual field defects the TOPCON-perimeter has a somewhat smaller sensitivity as a result of the different definition of the category "normal"; at the same time there is a tendency for showing up more "absolute defects" instead of "deep relative defects". Technical parameters and strategies are discussed critically taking into consideration the practical experience obtained during this first routine testing.

Adult↗

[Influence of luminous intensity, contrast and color on vision in patients with slight to severe visual defects (author's transl)].

Visual acuity was measured as a function of illuminance (1X; illumination vertical from above) or luminance (cd/m2; illumination of transparent texts from below) for various pathologic alterations of the eye accompanied by a decrease in visual performance (myopia magna with/without retinopathia myopica, astigmatism, senile cataract, aphakia after congenital cataract, macular degeneration, glaucoma etc.) with positive and negative contrast of reading texts. The degree of visual acuity in relation to illuminance or luminance is characteristic for each ocular disease, so that individual adjustment of illumination at the place of work is called for. Visual acuity is not measurably influenced by the color of the light used. Under directed illumination three-dimensional perception is independent of the angle of illumination; under diffuse illumination perception is drastically reduced.

Adolescent↗