A new type of model-based Roentgen stereophotogrammetric analysis for solving the occluded marker problem.

Roentgen stereophotogrammetric analysis (RSA) measures micromotion of an orthopaedic implant with respect to its surrounding bone. A problem in RSA is that the markers are sometimes overprojected by the implant itself. This study describes the so-called Marker Configuration Model-based RSA (MCM-based RSA) that is able to measure the pose of a rigid body in situations where less than three markers could be detected in both images of an RSA radiograph. MCM-based RSA is based on fitting a Marker Configuration model (MC-model) to the projection lines from the marker projection positions in the image to their corresponding Roentgen foci. An MC-model describes the positions of markers relative to each other and is obtained using conventional RSA. We used data from 15 double examinations of a clinical study of total knee prostheses and removed projections of the three tibial component markers, simulating occlusion of markers. The migration of the tibial component with respect to the bone, which should be zero, for the double examination is a measure of the accuracy of algorithm. With the new algorithm, it is possible to estimate the pose of a rigid body of which one or two markers are occluded in one of the images of the RSA radiograph with high accuracy as long as a proper MC-model of the markers in the rigid body is available. The new algorithm makes RSA more robust for occlusion of markers. This improves the results of clinical RSA studies because the number of lost RSA follow-up moments is reduced.

Biomechanical Phenomena↗

Estimating muscle attachment contours by transforming geometrical bone models.

For individualization of a biomechanical model, it is necessary to estimate the muscle attachments of the person to whom it is to be adapted. One of the methods to estimate muscle attachments is to use model transformations to transform a model with known muscle attachments to the bones of a person. We hypothesize that the location and shape of muscle attachment sites correlate with the shape of the bones they are attached to. If this hypothesis holds, it is possible to predict the location of muscle attachments when the shape of the bones is known. To validate this hypothesis, geometric models of three sets of shoulder bones were built. These models consist of 3-D surface models of the scapula, clavicle, and humerus, with the muscle attachment contours connected to them. By means of geometric transformations, the models were transformed, so the muscle attachments of the different data sets could be compared. Using these techniques, 50 per cent of the muscle attachment contours could be predicted with high accuracy. The muscle attachment contours that could not be predicted were all influenced by measurement errors. For 30 per cent of the muscle attachment contours, it was not possible to distinguish the interindividual differences from the inaccuracies of the method used. From this study, we concluded that most muscle attachment contours can be predicted by means of geometric models of the bones.

Algorithms↗

Evaluation of three pose estimation algorithms for model-based roentgen stereophotogrammetric analysis.

Model-based roentgen stereophotogrammetric analysis (RSA) uses a three-dimensional surface model of an implant in order to estimate accurately the pose of that implant from a stereo pair of roentgen images. The technique is based on minimization of the difference between the actually projected contour of an implant and the virtually projected contour of a model of that same implant. The advantage of model-based RSA over conventional marker-based RSA is that it is not necessary to attach markers to the implant. In this paper, three pose estimation algorithms for model-based RSA are evaluated. The algorithms were assessed on the basis of their sensitivities to noise in the actual contour, to the amount of drop-outs in the actual contour, to the number of points in the actual contour and to shrinkage or expansion of the actual contour. The algorithms that were studied are the iterative inverse perspective matching (IIPM) algorithm, an algorithm based on minimization of the difference (DIF) between the actual contour and the virtual contour, and an algorithm based on minimization of the non-overlapping area (NOA) between the actual and virtual contour. The results of the simulation and phantom experiments show that the NOA algorithm does not fulfil the high accuracy that is necessary for model-based RSA. The IIPM and DIF algorithms are robust to the different distortions, making model-based RSA a possible replacement for marker-based RSA.

Algorithms↗

Development and experimental validation of a three-dimensional finite element model of the human scapula.

A new modelling approach, using a combination of shell and solid elements, has been adopted to develop a realistic three-dimensional finite element (FE) model of the human scapula. Shell elements were used to represent a part of the compact bone layer (i.e. the outer cortical layer) and the very thin and rather flat part of the scapula--infraspinous fossa and supraspinous fossa respectively. Solid elements were used to model the remaining part of the compact bone and the trabecular bone. The FE model results in proper element shapes without distortion. The geometry, material properties and thickness were taken from quantitative computed tomography (CT) data. A thorough experimental set-up for strain gauge measurement on a fresh bone serves as a reference to assess the accuracy of FE predictions. A fresh cadaveric scapula with 18 strain gauges fixed at various locations and orientations was loaded in a mechanical testing machine and supported at three locations by linkage mechanisms interconnected by ball joints. This new experimental set-up was developed to impose bending and deflection of the scapula in all directions unambiguously, in response to applied loads at various locations. The measured strains (experimental) were compared to numerical (FE) strains, corresponding to several load cases, to validate the proposed FE modelling approach. Linear regression analysis was used to assess the accuracy of the results. The percentage error in the regression slope varies between 9 and 23 per cent. It appears, as a whole, that the two variables (measured and calculated strains) strongly depend on each other with a confidence level of more than 95 per cent. Considering the complicated testing procedure on a fresh sample of scapula, the high correlation coefficients (0.89-0.97), the low standard errors (29-105 micro epsilon) and percentage errors in the regression slope, as compared to other studies, strongly suggest that the strains calculated by the FE model can be used as a valid predictor of the actual measured strain. The model is therefore an alternative to a rigorous three-dimensional model based on solid elements only, which might often be too expensive in terms of computing time.

Aged↗

A new model-based RSA method validated using CAD models and models from reversed engineering.

Roentgen stereophotogrammetric analysis (RSA) was developed to measure micromotion of an orthopaedic implant with respect to its surrounding bone. A disadvantage of conventional RSA is that it requires the implant to be marked with tantalum beads. This disadvantage can potentially be resolved with model-based RSA, whereby a 3D model of the implant is used for matching with the actual images and the assessment of position and rotation of the implant. In this study, a model-based RSA algorithm is presented and validated in phantom experiments. To investigate the influence of the accuracy of the implant models that were used for model-based RSA, we studied both computer aided design (CAD) models as well as models obtained by means of reversed engineering (RE) of the actual implant. The results demonstrate that the RE models provide more accurate results than the CAD models. If these RE models are derived from the very same implant, it is possible to achieve a maximum standard deviation of the error in the migration calculation of 0.06 mm for translations in x- and y-direction and 0.14 mm for the out of plane z-direction, respectively. For rotations about the y-axis, the standard deviation was about 0.1 degrees and for rotations about the x- and z-axis 0.05 degrees. Studies with clinical RSA-radiographs must prove that these results can also be reached in a clinical setting, making model-based RSA a possible alternative for marker-based RSA.

Algorithms↗