MRI-guided needle localization of suspicious breast lesions: results of a freehand technique.

Magnetic resonance imaging (MRI) can detect clinically and mammographically occult breast lesions. In this study we report the results of MRI-guided needle localization of suspicious breast lesions by using a freehand technique. Preoperative MRI-guided single-needle localization was performed in 220 patients with 304 MRI-only breast lesions at our hospital between January 1997 and July 2004. Procedures were performed in an open 0.5-T Signa-SP imager allowing real-time monitoring, with patient in prone position, by using a dedicated breast coil. MRI-compatible hookwires were placed in a noncompressed breast by using a freehand technique. MRI findings were correlated with pathology and follow-up. MRI-guided needle localization was performed for a single lesion in 150 patients, for two lesions in 56 patients, and for three lesions in 14 patients. Histopathologic analysis of these 304 lesions showed 104 (34%) malignant lesions, 51 (17%) high-risk lesions, and 149 (49%) benign lesions. The overall lesion size ranged from 2.0-65.0 mm (mean 11.2 mm). No direct complications occurred. Follow-up MRI in 54 patients showed that two (3.7%) lesions were missed by surgical biopsy. MRI-guided freehand needle localization is accurate and allows localization of lesions anterior in the breast, the axillary region, and near the chest wall.

Adult↗

First use of a truly-hybrid X-ray/MR imaging system for guidance of brain biopsy.

The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches.

Adult↗

Temperature quantitation and mapping of frozen tissue.

A method was developed for quantitating the temperature within frozen tissue with the magnetic resonance (MR) parameter R2*. The pulse sequence uses half-pulse excitation and a short spiral readout to achieve echo times as short as 0.2 msec. Fiber-optic temperature sensors were inserted into bovine liver tissue. The tissue was frozen at one end while being held warm at the other end. Once steady state was reached, the parameter R2* was measured. A linear dependence of R2* on temperature was demonstrated. R2* is independent of freeze number and of the orientation of the temperature gradient with respect to the main magnetic field. Feasibility in a canine prostate during cryosurgery is demonstrated. J. Magn. Reson. Imaging 2001;13:99-104.

Animals↗

A truly hybrid interventional MR/X-ray system: feasibility demonstration.

A system enabling both x-ray fluoroscopy and MRI in a single exam, without requiring patient repositioning, would be a powerful tool for image-guided interventions. We studied the technical issues related to acquisition of x-ray images inside an open MRI system (GE Signa SP). The system includes a flat-panel x-ray detector (GE Medical Systems) placed under the patient bed, a fixed-anode x-ray tube overhead with the anode-cathode axis aligned with the main magnetic field and a high-frequency x-ray generator (Lunar Corp.). New challenges investigated related to: 1) deflection and defocusing of the electron beam of the x-ray tube; 2) proper functioning of the flat panel; 3) effects on B0 field homogeneity; and 4) additional RF noise in the MR images. We have acquired high-quality x-ray and MR images without repositioning the object using our hybrid system, which demonstrates the feasibility of this new configuration. Further work is required to ensure that the highest possible image quality is achieved with both MR and x-ray modalities.

Brain↗

Freehand iMRI-guided large-gauge core needle biopsy: a new minimally invasive technique for diagnosis of enhancing breast lesions.

The lack of reliable methods for minimally invasive biopsy of suspicious enhancing breast lesions has hindered the utilization of contrast-enhanced magnetic resonance imaging (MRI) for the detection and diagnosis of breast cancer. In this study, a freehand method was developed for large-gauge core needle biopsy (LCNB) guided by intraprocedural MRI (iMRI). Twenty-seven lesions in nineteen patients were biopsied using iMRI-guided LCNB without significant complications. Diagnostic tissue was obtained in all cases. Nineteen of the 27 lesions were subsequently surgically excised. Histopathologic analysis confirmed that iMRI-guided LCNB correctly distinguished benign lesions from malignancy in 18 of the 19 lesions. The histology revealed by core biopsy was partially discrepant with surgical biopsy in 2 of the other 19 lesions. Freehand iMRI-guided LCNB of enhancing breast lesions is promising. Larger studies are needed to determine the smallest lesion that can be sampled reliably and to precisely measure the accuracy of iMRI-guided LCNB as a minimally invasive tool to diagnose suspicious lesions found by breast MRI. J. Magn. Reson. Imaging 2001;13:896-902.

Adult↗

Temperature mapping of frozen tissue using eddy current compensated half excitation RF pulses.

Cryosurgery has been shown to be an effective therapy for prostate cancer. Temperature monitoring throughout the cryosurgical iceball could dramatically improve efficacy, since end temperatures of at least -40 degrees C are required. The results of this study indicate that MR thermometry based on tissue R(*)(2) has the potential to provide this information. Frozen tissue appears as a complete signal void on conventional MRI. Ultrashort echo times (TEs), achievable with half pulse excitation and a short spiral readout, allow frozen tissue to be imaged and MR characteristics to be measured. However, half pulse excitation is highly sensitive to eddy current distortions of the slice-select gradient. In this work, the effects of eddy currents on the half pulse technique are characterized and methods to overcome these effects are developed. The methods include: 1) eddy current compensated slice-select gradients, and 2) a correction for the phase shift between the first and second half excitations at the center of the slice. The effectiveness of these methods is demonstrated in R(*)(2) maps calculated within the frozen region during cryoablation.

Animals↗

Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.

RATIONALE AND OBJECTIVES: The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. MATERIALS AND METHODS: A digital flat-panel x-ray system (1,024(2) array of 200 microm pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). RESULTS: The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. CONCLUSION: Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.

Animals↗

Potential role of magnetic resonance imaging and other modalities in ductal carcinoma in situ detection.

Ductal Carcinoma In Situ (DCIS) is the earliest form of ductal cancer, with a high rate of care if treated early. This article outlines the use of breast imaging in DCIS diagnosis, including mammography, MR imaging, and nuclear medicine studies. While MR imaging and nuclear medicine show great promise in DCIS diagnosis, mammography remains the mainstay of DCIS detection by the presence of microcalcifications in early tumors on the mammogram.

Breast Neoplasms↗

Characterization of breast lesion morphology with delayed 3DSSMT: an adjunct to dynamic breast MRI.

The purpose of the study was to determine the sensitivity and specificity of various morphologic criteria in distinguishing malignant from benign breast lesions using a new sequence (3DSSMT) performed immediately after dynamic breast MRI. 3DSSMT combines a water-selective spectral-spatial excitation and an on-resonance magnetization transfer pulse with three-dimensional spoiled gradient-echo imaging. Morphologic features of 87 pathologically confirmed lesions were analyzed. The presence of either skin thickening, or a combination of a spiculated or microlobulated border, with a rim, ductal, linear, or clumped enhancement pattern was 94% specific and 54% sensitive for malignancy. Conversely, the presence of either a perfectly smooth border, a well-defined margin, non-enhancing internal septations, or a macrolobulated border was 97% specific and 35% sensitive for a benign diagnosis. In conclusion, delayed 3DSSMT discriminates a significant number of benign and malignant breast lesions; it has the potential to improve the diagnostic accuracy of dynamic breast MRI.

Breast↗

Dynamic breast MRI with spiral trajectories: 3D versus 2D.

A three-dimensional (3)D spiral sequence was developed for dynamic breast magnetic resonance (MR) imaging with much improved image quality. Partial Z phase encoding was applied to obtain thinner slices for a coverage of the whole breast. Comparison between the 3D and a previously developed multi-slice 2D spiral sequences was performed on ten healthy volunteers without contrast and five breast patients with gadolinium-diethylene triamine pentaacetic acid (Gd-DTPA). The 3D spiral images had significantly less off-resonance blurring and spiral artifacts. With a small compromise on temporal resolution (7.7 seconds in 2D and 10.6 seconds in 3D), we obtained 32 interpolated 3-5 mm slices (with 20 Z phase encodes) for a full coverage of 10-16 cm breast with the same 1 x 1 mm2 in-plane resolution as the 2D sequence, which had 12 8-13 mm slices. Contrast between glandular and soft tissue in normal breasts was increased by about 25%. The reduced repetition time in the 3D spiral acquisition led to an increased Gd-enhanced signal. The difference between the enhancement of malignant and benign lesions increased by sevenfold. We expect that this new development could lead to improved specificity in characterizing breast lesions using MR imaging.

Adult↗

Single-shot fluid attenuated inversion recovery (FLAIR) magnetic resonance imaging of the bladder.

The purpose of this study was to reduce artifacts and increase imaging speed in fluid-attenuated inversion recovery (FLAIR) imaging of the urinary bladder. An existing half-Fourier, single-shot fast spin-echo imaging sequence was modified to allow presaturation with a non-slice-selective inversion recovery pulse (NSI SSFLAIR). Four independent, blinded readers rated severity of bladder artifacts and image quality in six normal male volunteers. NSI SSFLAIR effectively suppressed bladder urine signal in all six cases using a TI of 2900-3100 msec. Although NSI SSFLAIR images were noisier than standard fast spin-echo images, imaging time was only 10 seconds per slice location. Furthermore, perceived image sharpness was only minimally reduced, and conspicuity of the seminal vesicles and peripheral zone of the prostate were nearly equivalent. NSI SSFLAIR provides rapid T2-weighted imaging of the bladder wall and perivesicular tissues with nearly complete negation of signal from urine in the bladder.

Artifacts↗

Magnetic resonance imaging of breast cancer: clinical indications and breast MRI reporting system.

Magnetic resonance imaging (MRI) is well suited to the investigation of breast cancer by virtue of its noninvasive nature and its multiplanar imaging abilities. MRI investigations showed high sensitivity but modest specificity for breast cancer detection and diagnosis. Most early studies tested the ability of MRI to evaluate and diagnose findings in the breast discovered by other imaging tests or by breast physical examination (1-4). When it was discovered that MRI identified small breast cancers undetected by mammography or breast ultrasound, MRI was used to estimate breast cancer extent in known cancer cases for surgical planning (5,6). These investigations led to the use of MRI in a multitude of breast imaging applications, raising further questions about the use of MRI in everyday practice: What are the indications for breast MRI in general practice? What is its role in light of other imaging tests? What are its benefits and limitations in each setting? How do I report these studies? The purpose of this article is to review the clinical background regarding indications for the use of MRI and relevant cases in which MRI can impact patient management in breast disease, and to describe new developments in reporting breast MRI studies. J. Magn. Reson. Imaging 2000;12:975-983.

Breast↗

The use of view angle tilting to reduce distortions in magnetic resonance imaging of cryosurgery.

Susceptibility artifacts from magnetic resonance (MR)-compatible cryoprobes can distort MR images of iceballs. In this work, we investigate the ability of view angle tilting (VAT) to correct susceptibility induced distortions in MR images of cryosurgery. The efficacy of VAT was tested in an ex vivo bovine liver model of cryosurgery using MR-compatible cryoprobes. Artifacts on high bandwidth fast spin echo images of freezing obtained with and without VAT were compared with photographs of the actual iceball shape and size. In vivo imaging with VAT was demonstrated during percutaneous MR-guided cryosurgery of pig liver and brain. VAT was most successful in reducing probe and iceball distortions when the imaging plane was normal to the cryoprobe, and the cryoprobe was perpendicular to the main magnetic field of the scanner. VAT had the greatest benefit when used to correct MR images of freezing when the surface of the iceball was relatively near to the cryoprobe. For large iceballs, the artifact was small so the VAT correction was less important. We conclude that VAT significantly reduced distortions in the shape of the signal void corresponding to the extent of freezing visualized during MR-guided cryosurgery. This improved ability to visualize the exact location of the cryoprobe, as well as the precise shape of the iceball, particularly during initial freezing when the iceball is small, has potential to significantly improve the accuracy of MR-guided cryosurgery of small lesions, and the accuracy of MR-assisted temperature calculations that are based on precise imaging of the probe location, and boundary geometry of the iceball.

Animals↗

Intraprocedural magnetic resonance imaging-guided interventions in the breast.

Despite the proven high sensitivity of magnetic resonance imaging (MRI) for invasive breast cancer, MRI has lagged behind mammography and sonography as an imaging modality for guiding interventional procedures because of the lack of suitable techniques. New imaging apparatuses, pulse sequences, and MR-compatible devices are beginning to enable MRI-guided breast interventions, including preoperative lesion localization and minimally invasive biopsy. MR-guided tumor ablation holds promise as a future therapy for breast cancer because of the ability of MRI to reveal the progress of heating and freezing, as well as the extent of ablated tissue.

Biopsy↗

Radiofrequency ablation of breast cancer: first report of an emerging technology.

HYPOTHESIS: Radiofrequency (RF) energy applied to breast cancers will result in cancer cell death. DESIGN: Prospective nonrandomized interventional trial. SETTING: A university hospital tertiary care center. PATIENTS: Five women with locally advanced invasive breast cancer, aged 38 to 66 years, who were undergoing surgical resection of their tumor. One patient underwent preoperative chemotherapy and radiation therapy, 3 patients received preoperative chemotherapy, and 1 had no preoperative therapy. All patients completed the study. INTERVENTIONS: While patients were under general anesthesia and just before surgical resection, a 15-gauge insulated multiple-needle electrode was inserted into the tumor under sonographic guidance. Radiofrequency energy was applied at a low power by a preset protocol for a period of up to 30 minutes. Only a portion of the tumor was treated to evaluate the zone of RF ablation and the margin between ablated and nonablated tissue. Immediately after RF ablation, the tumor was surgically resected (4 mastectomies, 1 lumpectomy). Pathologic analysis included hematoxylin-eosin staining and enzyme histochemical analysis of cell viability with nicotinamide adenine dinucleotide-diaphorase (NADH-diaphorase) staining of snap-frozen tissue to assess immediate cell death. MAIN OUTCOME MEASURE: Cancer cell death as visualized on hematoxylin-eosin-stained paraffin section and NADH-diaphorase cell viability stains. RESULTS: There was evidence of cell death in all patients. Hematoxylin-eosin staining showed complete cell death in 2 patients. In 3 patients there was a heterogeneous pattern of necrotic and normal-appearing cells within the ablated tissue. The ablated zone extended around the RF electrode for a diameter of 0.8 to 1.8 cm. NADH-diaphorase cell viability stains of the ablated tissue showed complete cell death in 4 patients. The fifth patient had a single focus of viable cells (<1 mm) partially lining a cyst. There were no perioperative complications related to RF ablation. CONCLUSIONS: Intraoperative RF ablation results in invasive breast cancer cell death. Based on this initial report of the use of RF ablation in breast cancer, this technique merits further investigation as a percutaneous minimally invasive modality for the local treatment of breast cancer.

Adult↗

Differentiation of hepatic malignancies from hemangiomas and cysts by T2 relaxation times: early experience with multiply refocused four-echo imaging at 1.5 T.

The purpose of this study was to examine hepatic lesions with a sequence designed to yield improved T2 measurements and evaluate the clinical utility of these measurements in distinguishing malignant from benign disease. Using a modified Carr-Purcell sequence incorporating features designed to compensate for imperfections in the imaging system, including a train of refocusing pulses emitted in an MLEV pattern oriented in composite fashion along all three coordinate axes, and a single spatially selective pulse placed immediately before a spiral readout, 14 benign lesions and 13 malignant lesions were evaluated prospectively with a conventional 1.5 T imager. The maximum, minimum, and mean T2 values of malignant lesions, hemangiomas, and cysts exceeded corresponding published values from spin-echo and echoplanar studies. The mean T2 value of the malignant lesions differed significantly (P < 0.0001) from those of hemangiomas and cysts. All malignant lesions and all benign lesions were distinguishable by their T2 values, which had ranges of no greater than 118.6 msec and no less than 134.3 msec, respectively. This early experience suggests that improved T2 measurements can facilitate the differentiation of hepatic malignancies from hemangiomas and cysts.

Carcinoma, Hepatocellular↗

Management of biopsy needle artifacts: techniques for RF-refocused MRI.

Several methods were investigated to improve the depiction of biopsy needles in radiofrequency (RF)-refocused magnetic resonance imaging. Distortion correction is performed by the use of view angle tilting (VAT): a gradient is employed on the slice-select axis during readout. Needle conspicuity is increased by offsetting the gradient echo from the spin echo and by inverting the 90 degrees RF pulse slice-select gradient. VAT effectively re-registers in-plane shifts. Since this method changes the projection angle through the slice, some structures appear blurred, while other structures appear sharper. VAT does not correct errors in slice selection. Offsetting the spin echo from the gradient echo increases needle conspicuity but can result in a shift in the apparent location of the needle. Inverting the 90 degrees slice-select gradient effectively increases the needle conspicuity with no shift in the needle location. These methods provide an easy and interactive means to manipulate needle artifacts but should be used cautiously.

Artifacts↗