Publications and source records attributed to B Kiefer.

At least 19 recordsLinked to original sources

Prostate biopsy in the supine position in a standard 1.5-T scanner under real time MR-imaging control using a MR-compatible endorectal biopsy device.

Thirty-seven consecutive patients with elevated PSA levels and negative tumor prostate biopsies underwent a MR-guided prostate biopsy in a 1.5-T scanner in the supine position. After localization of suspected tumor areas using an endorectal coil and two body-phased array coils, the biopsy device was positioned without any repositioning of the patient. The biopsy device consisted of a mount, a ball joint, a positioning stage and an insertion stage with a needle guide, which was filled with a MR-visible fluid to control positioning of the needle using a balanced steady-state free precession sequence (TrueFISP) and a high-resolution turbo spin echo (T2-TSE) sequence. Core biopsies were taken manually in the magnet. The biopsy needle could be correctly positioned in all cases. Suspected lesions with a diameter > or =10 mm could be successfully punctured. Four to nine (mean = 6) biopsies were taken per patient. In 14 patients, prostate cancer was confirmed at histology. Twenty-four biopsies positive for cancer were performed in 14 patients. A correct correlation was found between the site of biopsy and histology. MR-guided prostate biopsy can be effective in increasing primary positive tumor biopsy results in patients with a history of negative tumor TRUS-guided prostate biopsies.

Adenocarcinoma↗

Double echo steady state magnetic resonance imaging of knee articular cartilage at 3 Tesla: a pilot study for the Osteoarthritis Initiative.

BACKGROUND: Quantitative magnetic resonance imaging (qMRI) may provide valuable measures of cartilage morphology in osteoarthritis (OA) but has been confined to sequences with relatively long acquisition times at 1.5 Tesla (T). OBJECTIVE: To test the accuracy and precision of knee cartilage qMRI with a fast double echo, steady state (DESS) sequence with water excitation (we) at 3 T. METHODS: As a pilot study for the Osteoarthritis Initiative, test-retest MR images were acquired in the knees of 19 participants with no OA to moderate degrees of clinical OA. Two double oblique coronal fast low angle shot (FLASHwe) sequences (1.5 mm slice thickness) were acquired at 3 T, and two sagittal DESSwe sequences (0.7 mm slice thickness). Double oblique coronal multiplanar reformats (MPR) were performed (1.5 mm slice thickness) from the sagittal DESSwe. Knee joint cartilage plates were quantified unpaired in random order with blinding to subject identification. RESULTS: In the femorotibial joint, precision errors (root mean square coefficient of variation in % for unpaired analysis) for cartilage volume and thickness were 3.0-6.4% with coronal FLASHwe, 2.4-6.2% with coronal MPR DESSwe, and 2.3-8.2% with sagittal DESSwe. Correlation coefficients between DESSwe and FLASHwe ranged from r = 0.88 to 1.0. In the femoropatellar joint, precision errors (sagittal DESSwe) were 3.4-8.5%. CONCLUSIONS: DESSwe permits accurate and precise analysis of cartilage morphology in the femorotibial joint at 3 T. Further studies are needed to examine the accuracy of DESSwe in the femoropatellar joint and its ability to characterise sensitivity to longitudinal changes in cartilage morphology.

Adult↗

[Feasibilities and limitations of high field parallel MRI].

In medical magnetic resonance imaging (MRI) it is standard to use MR scanners with a field strength of 1.5 Tesla. Recently, an ongoing development to higher field strength can be observed and a new clinical standard at 3.0 Tesla seems to be established. High field MRI with its intrinsic higher signal to noise ratio (SNR) can enable new applications of MRI in medical diagnosis, or can serve to improve existing methods. It is important to note, that the use of high field MRI is not without its limitations. Besides the SNR, other unwanted effects increase with a higher field strength. Without correction, these high field problems cause a serious loss in image quality. An elegant way to address these problems is the use of parallel imaging. In many clinical applications, parallel MRI (pMRI) is part of the standard protocol, because pMRI can enhance virtually every MRI application, without necessarily affecting the contrast behavior of the underlying imaging sequence. In high field MRI, besides the speed advantage of pMRI, the positive influence on high field specific problems and therefore on the image quality will be of major importance.

Artifacts↗

[Determining global heart function with real time TrueFISP in one respiratory cycle].

Real-time multislice cine techniques lead to inaccurate results in ventricular volumes based on limited temporal resolution. The purpose of the study is to evaluate a real-time cine technique with parallel imaging algorithms in comparison to standard segmented techniques. Twelve patients underwent cardiac cine MRI using real-time multislice cine trueFISP. Temporal resolution was improved using parallel acquisition techniques (iPAT) and data acquisition was performed in a single breath-hold along the patients' short axis. Evaluation of EDV, ESV, EF and myocardial mass was performed and results compared to a standard segmented single-slice cine trueFISP. Combination of real-time cine trueFISP and iPAT provided a temporal resolution of 48 ms. Results of the multislice approach showed an excellent correlation to standard single-slice trueFISP for EDV (0.94, p <0.001), ESV (0.97, p <0.001) EF (0.99, p <0.001) and myocardial mass (0.93, p <0.001). No significant differences could be found. The use of parallel acquisition techniques (PAT) allow for a substantial improvement of temporal resolution in real-time cine MRI (<50 ms). Therefore these techniques enable an accurate and exact quantification of global ventricular function.

Algorithms↗

[Cardiovascular whole body MRI with parallel imaging].

PURPOSE: To create a whole-body cardiovascular MRI protocol with parallel imaging (iPAT). MATERIAL AND METHODS: Twenty two persons participated in the whole body scan. Due to iPAT high resolution imaging of the heart could be performed. 3D contrast enhanced MR angiography (3D-CE-MRA) took only 62 s to cover the whole body at a spatial resolution of less than 1.4x1.0x1.5mm(3). Scan time for HASTE lung imaging could be reduced by the factor of 2 while maintaining the signal to noise ratio (SNR). Image quality was rated by 2 radiologists blinded to each other. RESULTS: Mean scan time was 104 min on the standard system and less than 80 min on the new system. 75% of all MRA segments were rated good in terms of vessel conspicuity, more than 80% had no venous overlay. One case of distal occlusion of the anterior tibial artery and two cases of myocardial infarction were detected. CONCLUSION: Parallel imaging offers the possibility of fast whole body imaging. A combination of morphologic and functional imaging can be performed within less than 80 min.

Adult↗

Comparison of intracranial 3D-ToF-MRA with and without parallel acquisition techniques at 1.5T and 3.0T: preliminary results.

PURPOSE: To evaluate the performance of four 3D-ToF magnetic resonance angiography (MRA) sequences with and without integrated parallel acquisition techniques (iPAT) at 1.5T and 3.0T in imaging intracranial vessels. MATERIAL AND METHODS: Seven volunteers and 5 patients (4 aneurysms, 1 AVM) underwent 3D-ToF-MRA at 1.5T (Magnetom Sonata) and 3.0T (Magnetom Trio) with and without parallel acquisition techniques (iPAT) using similarly designed 8-channel phased-array head coils. Imaging time of the pulse sequences was set to 7.15 and 7.35 min, respectively. Images were analyzed quantitatively by calculating signal-to-noise (SNR) and contrast-to-noise (CNR) ratios of proximal M2 segments and qualitatively by using a 5-point scale. RESULTS: SNR and CNR were significantly higher for both 3D-ToF sequences at 3.0T compared with both pulse sequences at 1.5T. The highest SNR and CNR were obtained at 3.0T without iPAT. However, because of a higher spatial resolution (matrix 512 x 640) visualization of small vessel details was best at 3.0T with iPAT. CONCLUSION: Intracranial 3D-ToF-MRA at 3.0T offers superior image quality compared with 1.5T, particular in the delineation of smaller vessels. In contrast to 1.5T, implementation of iPAT at 3.0T is of additional benefit since the high SNR available at 3.0T allows for higher spatial resolution without prolongation of measurement time.

Artifacts↗

The maximum attainable body size of herbivorous mammals: morphophysiological constraints on foregut, and adaptations of hindgut fermenters.

An oft-cited nutritional advantage of large body size is that larger animals have lower relative energy requirements and that, due to their increased gastrointestinal tract (GIT) capacity, they achieve longer ingesta passage rates, which allows them to use forage of lower quality. However, the fermentation of plant material cannot be optimized endlessly; there is a time when plant fibre is totally fermented, and another when energy losses due to methanogenic bacteria become punitive. Therefore, very large herbivores would need to evolve adaptations for a comparative acceleration of ingesta passage. To our knowledge, this phenomenon has not been emphasized in the literature to date. We propose that, among the extant herbivores, elephants, with their comparatively fast passage rate and low digestibility coefficients, are indicators of a trend that allowed even larger hindgut fermenting mammals to exist. The limited existing anatomical data on large hindgut fermenters suggests that both a relative shortening of the GIT, an increase in GIT diameter, and a reduced caecum might contribute to relatively faster ingesta passage; however, more anatomical data is needed to verify these hypotheses. The digestive physiology of large foregut fermenters presents a unique problem: ruminant-and nonruminant-forestomachs were designed to delay ingesta passage, and they limit food intake as a side effect. Therefore, with increasing body size and increasing absolute energy requirements, their relative capacity has to increase in order to compensate for this intake limitation. It seems that the foregut fermenting ungulates did not evolve species in which the intake-limiting effect of the foregut could be reduced, e.g. by special bypass structures, and hence this digestive model imposed an intrinsic body size limit. This limit will be lower the more the natural diet enhances the ingesta retention and hence the intake-limiting effect. Therefore, due to the mechanical characteristics of grass, grazing ruminants cannot become as big as the largest browsing ruminant. Ruminants are not absent from the very large body size classes because their digestive physiology offers no particular advantage, but because their digestive physiology itself intrinsically imposes a body size limit. We suggest that the decreasing ability for colonic water absorption in large grazing ruminants and the largest extant foregut fermenter, the hippopotamus, are an indication of this limit, and are the outcome of the competition of organs for the available space within the abdominal cavity. Our hypotheses are supported by the fossil record on extinct ruminant/tylopod species which did not, with the possible exception of the Sivatheriinae, surpass extant species in maximum body size. In contrast to foregut fermentation, the GIT design of hindgut fermenters allows adaptations for relative passage acceleration, which explains why very large extinct mammalian herbivores are thought to have been hindgut fermenters.

Adaptation, Biological↗

Resolution enhancement in lung 1H imaging using parallel imaging methods.

Resolution in (1)H lung imaging is limited mainly by the acquisition time. Today, half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequences, with short echo time (TE) and short interecho spacing (T(inter)) have found increased use in lung imaging. In this study, a HASTE sequence was used in combination with a partially parallel acquisition (PPA) strategy to increase the spatial resolution in single-shot (1)H lung imaging. To investigate the benefits of using a combination of single-shot sequences and PPA, five healthy volunteers were examined. Compared to conventional imaging methods, substantially increased resolution is obtained using the PPA approach. Representative in vivo (1)H lung images acquired with a HASTE sequence in combination with the generalized autocalibrating partially parallel acquisition (GRAPPA) method, up to an acceleration factor of three, are presented.

Humans↗

Control of chemical reactions by feedback-optimized phase-shaped femtosecond laser pulses

Tailored femtosecond laser pulses from a computer-controlled pulse shaper were used to optimize the branching ratios of different organometallic photodissociation reaction channels. The optimization procedure is based on the feedback from reaction product quantities in a learning evolutionary algorithm that iteratively improves the phase of the applied femtosecond laser pulse. In the case of CpFe(CO)2Cl, it is shown that two different bond-cleaving reactions can be selected, resulting in chemically different products. At least in this case, the method works automatically and finds optimal solutions without previous knowledge of the molecular system and the experimental environment.

Journal Article↗

Cooperation of two PEA3/AP1 sites in uPA gene induction by TPA and FGF-2.

We have previously shown in NIH 3T3 fibroblasts that treatment with 12-O-tetradecanoylphorbol 13-acetate (TPA) or fibroblast growth factor-2 (FGF-2) activates the Ras/Erk signaling pathway in NIH 3T3 fibroblasts, leading to the induction of the urokinase-type plasminogen activator (uPA) gene. In this study, we characterize cis-acting elements involved in this induction. DNase I hypersensitive (HS) site analysis of the uPA promoter showed that two regions were enhanced after TPA and FGF-2 treatment. One was located 2.4kb upstream of the transcription start site (-2.4kb), where a known PEA3/AP1 (AGGAAATGAGGTCAT) element is located. The other was located in a previously undefined far upstream region. Sequencing of this region revealed a similar AP1/PEA3 (GTGATTCACTTCCT) element at -6.9 kb corresponding to the HS site. Deletion analysis of the uPA promoter in transient transfection assays showed that both PEA3/AP1 elements are required for full inducibility, suggesting a synergism between the two elements. When the two sites were inserted together upstream of a minimal promoter derived from the thymidine kinase gene, expression of the reporter gene was more strongly induced by TPA and FGF-2 than with either of the two elements alone. Alone, the -6.9 element was more potent than the -2.4 element. The involvement of AP1 as well as Ets transcription factors was confirmed by examining different promoter constructs containing deletions in either the AP-1 or the PEA3 element, and by using an expression plasmid for dominant negative Ets-2. Electromobility shift analyses using specific antibodies showed that c-Jun and, JunD bind to both elements with or without induction. In addition, ATF-2 binds to the -2.4-kb element even without induction and c-Fos to the -6.9-kb element only after induction. Accordingly, overexpression of c-Fos caused induction from the -6.9-kb element, but reduced induction from the -2.4-kb element. The involvement of the Ets-2 transcription factor was shown by using expression plasmids for wild-type and dominant negative Ets-2.

3T3 Cells↗

Preliminary experience with a new double-echo half-Fourier single-shot turbo spin echo acquisition in the characterization of liver lesions.

A new double-echo half-Fourier single-shot turbo spin echo technique has been implemented in which two images are obtained per excitation pulse, one with an echo time (TE) of 60 ms and another with a TE of 438 ms. The acquisition window per image is 380 ms and is determined by the echo spacing of 4.3 ms and the echo train length of 88 for images with resolution of 160 x 256. No breath holding was performed. The aim of the study was to test whether the additional information of the late TE image improves the characterization of liver lesions. Twenty-eight patients with 39 focal liver lesions (9 cysts, 11 hemangiomas, and 19 solid lesions) were imaged with the new technique, and signal intensity (SI) ratios of lesion and liver were obtained. A t-test analysis showed that in the TE 60 ms image, SI ratios of cysts and hemangiomas were not significantly different, whereas in the TE 438 ms images the two types of lesions can be classified. Signal intensity ratios of solid lesions were in both images clearly lower than those of cysts and hemangiomas. The technique, therefore, seems a promising and straightforward new tool for the characterization of liver lesions.

Cysts↗

Visualization of urinary tract dilatation: value of single-shot MR urography.

The purpose of this study was to evaluate detection of urinary tract dilatation, depiction of obstruction level and determination of cause with single-shot MR imaging in an acquisition time of 2.8 s. Heavily T2-weighted single-shot MR images in 50 patients with ureterohydronephrosis as suspected by ultrasound were prospectively compared with IV urography and clinical outcome. Imaging techniques were obtained within a maximum time interval of 4 h and assessed independently on the same day. Single-shot MR urography was able to demonstrate dilatation and obstruction levels in 96 % of urinary tracts in accordance with X-ray urograms. In 4 patients with a unilaterally negative IV urogram, obstruction levels were demonstrated in single-shot MR urography. Single-shot MR urography did not depict 2 of 7 collecting systems with mild dilatation and contralateral undilated ureters were not adequately visible. Single-shot MR urography consistently visualizes dilated urinary tracts and obstruction levels in moderate and severe dilatation. Single-shot MR urography may be an alternative for IV urography in cases of renal impairment, when iodinated contrast or the application of X-rays is contraindicated, and may help in avoiding direct ureteropyelography. Single-shot MR urography rarely allows determination of the cause of urinary tract dilatation.

Adult↗

Magnetic resonance chondro-crassometry (MR CCM): a method for accurate determination of articular cartilage thickness?

A method for the assessment of articular cartilage thickness based on MRI is presented and its accuracy and reproducibility tested. Six specimens of human patellae were imaged, using a fat-suppressed FLASH 3D sequence, and sectioned with a high-precision band saw. The regional distribution of articular cartilage thickness was determined from the MR images and from the anatomical sections (intervals of 0.5 mm). With image analysis 50-90% of the image points were found to lie within exactly the same thickness interval in corresponding patterns, and less than 17% deviated more than 0.5 mm. More than 85% of all pixels were reproducible with MRI after new positioning of the joint. No influence of the read-out direction and no important differences between areas of thin and thick cartilage could be detected. The authors conclude that MR chondro-crassometry can provide accurate and reproducible information on cartilage thickness.

Adult↗

Assessment of normal patellar cartilage volume and thickness using MRI: an analysis of currently available pulse sequences.

OBJECTIVE: The objective of this study was to analyse the potential of magnetic resonance imaging for valid determination of patellar cartilage thickness, comparing currently available pulse sequences. DESIGN: In six patients and one cadaver the cartilage was repetitively imaged employing three spin-echo and six three-dimensional gradient-echo sequences. In the cadaveric specimen the total volume and the regional distribution of cartilage thickness were assessed and compared with the values obtained from anatomical sections by image analysis. RESULTS AND CONCLUSIONS: The FLASH and fat-suppressed FLASH sequences allowed the most accurate determination of the cartilage volume and thickness. Fat-suppression considerably increased the contrast of the cartilage to the synovial fluid, fat and bone marrow, yielding higher reproducibility of the volumetric measurements. The remaining difference from the anatomical volume and thickness may be because the calcified cartilage is not delineated by magnetic resonance imaging.

Adult↗