Simultaneous frequency and dissipation factor QCM measurements of biomolecular adsorption and cell adhesion.

We have measured the energy dissipation of the quartz crystal microbalance (QCM), operating in the liquid phase, when mono- or multi-layers of biomolecules and biofilms form on the QCM electrode (with a time resolution of ca. 1 s). Examples are taken from protein adsorption, lipid vesicle adsorption and cell adhesion studies. Our results show that even very thin (a few nm) biofilms dissipate a significant amount of energy owing to the QCM oscillation. Various mechanisms for this energy dissipation are discussed. Three main contributions to the measured increase in energy dissipation are considered. (i) A viscoelastic porous structure (the biofilm) that is strained during oscillation, (ii) trapped liquid that moves between or in and out of the pores due to the deformation of the film and (iii) the load from the bulk liquid which increases the strain of the film. These mechanisms are, in reality, not entirely separable, rather, they constitute an effective viscoelastic load. The biofilms can therefore not be considered rigidly coupled to the QCM oscillation. It is further shown theoretically that viscoelastic layers with thicknesses comparable to the biofilms studied in this work can induce energy dissipation of the same magnitude as the measured ones.

Adsorption↗

Chemical characterization and reactivity of iron chelator-treated amphibole asbestos.

Iron in amphibole asbestos is implicated in the pathogenicity of inhaled fibers. Evidence includes the observation that iron chelators can suppress fiber-induced tissue damage. This is believed to occur via the diminished production of fiber-associated reactive oxygen species. The purpose of this study was to explore possible mechanisms for the reduction of fiber toxicity by iron chelator treatments. We studied changes in the amount and the oxidation states of bulk and surface iron in crocidolite and amosite asbestos that were treated with iron-chelating desferrioxamine, ferrozine, sodium ascorbate, and phosphate buffer solutions. The results have been compared with the ability of the fibers to produce free radicals and decompose hydrogen peroxide in a cell-free system in vitro. We found that chelators can affect the amount of iron at the surface of the asbestos fibers and its valence, and that they can modify the chemical reactivity of these surfaces. However, we found no obvious or direct correlations between fiber reactivity and the amount of iron removed, the amount of iron at the fiber surface, or the oxidation state of surface iron. Our results suggest that surface Fe3+ ions may play a role in fiber-related carboxylate radical formation, and that desferrioxamine and phosphate groups detected at treated fiber surfaces may play a role in diminishing and enhancing, respectively, fiber redox activity. It is proposed that iron mobility in the silicate structure may play a larger role in the chemical reactivity of asbestos than previously assumed.

Asbestos, Amphibole↗

Bone response to surface-modified titanium implants: studies on the early tissue response to machined and electropolished implants with different oxide thicknesses.

The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.

Animals↗

Bone response to surface modified titanium implants: studies on electropolished implants with different oxide thicknesses and morphology.

In a series of experimental studies, bone formation was analysed around systematically modified titanium implants. In the present study, machined, electropolished and anodically oxidized implants were prepared, surface characterized and inserted in the cortical bone of rabbits (7 wks and 12 wks). SEM, scanning Auger electron spectroscopy and atomic force microscopy revealed no differences in surface composition but marked differences in oxide thickness, surface topography and roughness. Light microscopic morphology and morphometry showed that all implants were in contact with bone, and had a large proportion of bone within the threads. The smooth, electropolished implants were surrounded by less bone than the machined implants with similar oxide thickness, (4-5 nm) and the anodically oxidized implants with thicker oxides (21 nm and 180 nm, respectively) after 7 wks. These studies show that a high degree of bone contact and bone formation can be achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, it appears that a reduction of surface roughness may influence the rate of bone formation in rabbit cortical bone.

Animals↗

Site-specific adhesion of Staphylococcus epidermidis (RP12) in Ti-Al-V metal systems.

Staphylococcus epidermidis (RP12) adhesion patterns were studied on the following titanium (Ti)-aluminium (Al)-vanadium (V) metal systems: (i) microfabricated samples consisting of Ti, Al and V islands deposited onto Ti or V substrata, (ii) pure Ti, Al and V metals, and (iii) medical grade Ti6Al4-V alloy. All of these surfaces were covered with their respective oxides formed upon exposure of the metals to air. Quantitative analysis of the number of cells bound per unit area indicates that S. epidermidis (RP12) exhibits greatest adhesion to pure V surfaces. When exposed to surfaces having controlled spatial variations in chemical composition on the 10 microns scale (microfabricated samples), the bacteria preferentially populate V islands versus Ti or Al substrata. In the case of the biphasic Ti6Al4V alloy, the bacteria tend to adhere to V-rich, mixed phase regions and phase boundaries. These findings demonstrate that enhanced and preferential adhesion of S. epidermidis (RP12) occurs on V surfaces in Ti-Al-V metal systems and suggest that bacterial interactions are influenced by surface oxide composition.

Alloys↗

Material-tissue interfaces: the role of surface properties and processes.

The introduction of a foreign material into living tissue--intentionally as in biomedical applications (implants, protheses, drugs) or unintentionally as when minerals or fibers are inhaled--results in the creation of interfaces between the material and the surrounding tissue. This article identifies and discusses the possible role of material surface properties and molecular processes occurring at such interfaces. For kinetic and thermodynamic reasons, surfaces are different from the corresponding bulk of the material, and contain reactive (unsaturated) bonds, which in turn lead to the formation of surface reactive layers (e.g., surface oxides on metals) and adsorbed contamination layers. The encounter with the biological environment leads to further surface reactions modifying the surface, and to the adsorption of water, ions, and biomolecules, which are continuously exchanged. The exact nature of the dynamic, adsorbed water, ions, and biomolecule coating in turn influences the behavior of cells approaching the material surface, and hence the tissue response.

Animals↗

Preparation of ultra-thin oxide windows on titanium for TEM analysis.

Using submerged jet electropolishing, extremely thin (less than 10 nm), continuous, thermal oxide "windows" have been prepared on polycrystalline titanium (Ti). The preparation technique is described in detail. It has allowed a systematic investigation of the structure of thermal surface oxide layers on Ti in the thickness range 6-40 nm, corresponding to oxidation temperatures 100-450 degrees C. Auger electron spectroscopy was used for oxide characterization and for depth profiling to determine oxide thickness. The thinnest oxides, less than 10 nm, are amorphous, morphologically homogeneous, and with essentially no contrast in the transmission electron microscopy (TEM) pictures. As the oxide thickness is increased up to 40 nm, a texture corresponding to the grain structure of the oxidized metal becomes gradually more visible. At the same time the oxide becomes increasingly more crystalline. The results are compared with previously published corresponding results for thicker anodic oxides on Ti.

Microscopy, Electron↗

Method for ultrastructural studies of the intact tissue-metal interface.

Samples were prepared for ultrastructural studies of the intact interface between metallic implants and tissue by transmission electron microscopy. The method is based on plastic embedding of implant and tissue and subsequent removal of the bulk metal by electrochemical dissolution (electropolishing), to facilitate preparation of ultrathin sections for transmission electron microscopy. Surface sensitive spectroscopy (Auger electron microscopy and X-ray photoemission spectroscopy) and transmission electron microscopy EDX results show that the method produces samples with an intact interface, containing the implant surface oxide and the adjacent tissue. Examples of application of the method on titanium, zirconium and aluminium implants in soft tissue are given.

Aluminum↗

Biomaterial and implant surfaces: on the role of cleanliness, contamination, and preparation procedures.

Material specificity in implant-tissue interactions derives primarily from the surface properties (chemical composition, microstructure, etc.) of the implant. This article addresses several questions related to implant and biomaterial surfaces: What is the status of real implant surfaces (composition, cleanliness, contamination, microstructure, etc.), and how does it vary with preparation procedures? Can the surface status be varied and analyzed in a controlled manner? How significant are surface status variations for in vivo function? And so on. We discuss clean surfaces, how they are contaminated, and how the contamination may affect the properties. We also discuss different preparation procedures, such as conventional machining, plasma treatment, and sterilization. Three important conclusions are drawn: (i) The surface status of a particular implant material may vary widely depending on its preparation and handling history. (ii) The surface status of implants is expected to be important for in vivo function, and should thus be controlled and standardized. (iii) It is usually not possible to predict how a change in surface status will affect the long-term, in vivo function of an implant.

Biocompatible Materials↗

Accelerated oxide growth on titanium implants during autoclaving caused by fluorine contamination.

Titanium implants were occasionally found to be strongly discoloured after autoclaving. The discolouration is shown to be due to an accelerated growth of the surface oxide that covers the implants. Oxide thicknesses up to 650 A have been observed, i.e. more than ten times thicker than on normal implants. By applying surface sensitive spectroscopies (SIMS and XPS or ESCA) it is also shown that these oxide films contain considerable amounts of fluorine, alkali metals and silicon. Screening tests with alkali-halide solutions identify fluorine as the impurity responsible for the accelerated oxide growth. Discolouration after autoclaving can be observed for fluorine contaminations down to the ppm level. In those cases where discolouration was observed in the clinical situation, the source of fluorine was the textile cloths in which the titanium implant storage box had been wrapped during the autoclaving procedure. The cloths contained residual Na2SiF6 which had been used as an additive to the rinsing water used in the last step of the cloth laundry procedure. Since the biocompatibility of titanium implants is closely related to their surface oxides it is advisable to avoid all sources of fluorine in the implant preparation procedures.