Search PubMedSearch

Biomedical subjects

B K Rutt

Publications and source records attributed to B K Rutt.

At least 19 recordsLinked to original sources

Differences in perceived shape from shading correlate with activity in early visual areas.

The perception of shape from shading depends on the orientation of the shading gradient [1] [2] [3] [4]. Displays composed of elements with vertically oriented shading gradients of opposite polarity produce a strong and stable percept of 'concave' and 'convex' elements. If the shading gradients are rotated 90 degrees , the depth percept is reduced and appears much more ambiguous. Results from psychophysical [1] [2] [3] [4] [5] [6], neuropsychological [7] and computational studies [8] [9] suggest that the perception of shape from shading engages specific mechanisms in early cortical visual areas. In a three-dimensional functional magnetic resonance imaging (fMRI) study at 1.5 Tesla using a three-dimensional, interleaved-echoplanar imaging technique and a surface radio frequency (RF) coil placed under the visual cortex, we investigated the activity in these early visual areas associated with viewing shape from shading displays at two different orientations. We found significantly greater activation in area V1 and neighbouring low-level visual areas of cortex when subjects viewed displays that led to weak and unstable depth percepts than when they viewed displays that led to strong and stable depth percepts.

Adult

Polyvinyl alcohol cryogel: an ideal phantom material for MR studies of arterial flow and elasticity.

The authors present a unique application of polyvinyl alcohol (PVA) cryogel as an anthropomorphic, elastic, vascular phantom material that can be used in MR imaging. The composition consists of two nontoxic ingredients: water and PVA. The biomechanical and MR properties can be adjusted to be similar to those of excised porcine aortas by varying the number of freeze-thaw cycles to which the PVA solution is exposed. The authors present the T1, T2, shrinkage, and tensile properties of PVA cryogel tubes as a function of freeze-thaw cycles. MR images of a dual elastic aortic phantom undergoing pulsatile motion are shown.

Animals

Quantitative diffusion imaging in implanted human breast tumors.

Quantitative diffusion measurements were performed in tumors arising from inoculation of nude mice with two human breast cancer cell lines (MCF7 and T47D) to evaluate the specificity of this technique for characterizing solid tumors. ADC maps were compared to histology and correlated well with gross tumor morphology. Measured ADCs were highly specific for viable and necrotic tumor in the five T47D tumors included in this study (P < 0.02), while only two of the five MCF7 tumors studied developed distinguishable areas of necrosis. No statistically significant difference was observed in ADCs from viable tumor between the different cell lines (P > 0.05).

Animals

Experimental determination of the BOLD field strength dependence in vessels and tissue.

High resolution functional MRI (fMRI) experiments were performed in human visual cortex at 0.5, 1.5, and 4 T to determine the blood oxygenation level dependent (BOLD) field strength response within regions of obvious venous vessels and cortical gray matter ("tissue"). T2*-weighted FLASH images were collected in single- and multi-echo mode and used to determine the intrinsic BOLD parameters, namely, signal-to-noise ratio (psi), the apparent transverse relaxation rate (R2*) and the change in R2* (deltaR2*) between the activated and baseline states. The authors find the average percentage signal change (deltaS/S, measured at TE = T2*) to be large in vessels (13.3 +/- 2.3%, 18.4 +/- 4.0%, and 15.1 +/- 1.2%) compared with that in tissue (1.4 +/- 0.7%, 1.9 +/- 0.7%, and 3.3 +/- 0.2%) at 0.5, 1.5, and 4 T, respectively. The signal-to-noise ratio in optimized, fully relaxed proton density weighted gradient echo images was found to increase linearly with respect to the static magnetic field strength (B0). The predicted upper bound on BOLD contrast-to-noise ratio (deltaS/R)max as a function of field strength was calculated and found to behave less than linearly in voxels containing vessels larger than the voxel itself and greater than linearly in voxels containing a mixture of capillaries and veins/venules with a diameter less than that of the voxel.

Humans

Improved MR images of arterial specimens by submersion in trichlorotrifluoroethane.

MR images of ex vivo arterial specimens immersed in 1,1,2-trichloro-1,2,2-trifluoroethane (R-113) have improved signal-to-noise ratio and contrast-to-noise ratio. R-113 has no hydrogen atoms, so it yields no proton signal; hence, the contrast between the specimen and its background is maximized. SNR is maximized because (i) R-113 is nonconductive so that coil loading and inductive noise are minimized, and (ii) the volume susceptibility of R-113 closely matches that of water and tissue so that T2* effects are minimized. Short-term submersion of porcine aortas in R-113 was found to have no significant effect on the artery's hydration level, relaxation time, tensile strength, and structure or quantity of elastin, collagen, or smooth muscle cells.

Animals

Effects of polar sampling in k-space.

Magnetic resonance imaging allows numerous k-space sampling schemes such as cartesian, polar, spherical, and other non-rectilinear trajectories. Non-rectilinear MR acquisitions permit fast scan times and can suppress motion artifacts. Still, these sampling schemes may adversely affect the image characteristics due to aliasing. Here, the Fourier aliasing effects of uniform polar sampling, i.e., equally spaced radial and azimuthal samples, are explained from the principal point spread function (PSF). The principal PSF is determined by assuming equally spaced concentric ring samples in k-space. The radial effects such as replication, smearing, truncation artifacts, and sampling requirements, are characterized based on the PSF.

Image Processing, Computer-Assisted

MR measurement and numerical simulation of steady flow in an end-to-side anastomosis model.

Magnetic resonance phase contrast velocity imaging ('MR PC velocimetry') is a powerful tool for measuring blood velocity. While it has been demonstrated that MR PC velocimetry can accurately measure velocity profiles in simple, unidirectional flows, errors can arise when measuring the more complex, multidirectional flows of clinical importance. In this work, we have compared MR PC velocity measurements with numerical simulations of steady flow in a physiologically relevant model of an end-to-side anastomosis, which produces many of the complex flow features expected in vivo. MR PC velocity profiles, measured using both 2D and 3D pulse sequences, showed very good agreement with numerically computed profiles, although at 2D PC data showed slightly larger errors than the 3D PC data in regions of high accelerations and oblique flow, likely due to displacement artifacts. We conclude that, under ideal conditions, MR phase contrast velocimetry can measure complex flow patterns to within 15% accuracy, but that care should be taken when using 2D pulse sequences to measure such complex flows.

Anastomosis, Surgical

Geometric characterization of stenosed human carotid arteries.

RATIONALE AND OBJECTIVES: The geometry of stenosed carotid bifurcations was analyzed to determine average representations for several stenosis grades. METHODS: Film angiograms of 62 patients with internal carotid artery stenoses were digitized. Residual lumen boundaries were manually outlined. The outlines were processed with a computer to extract geometric measurements. The measurements were grouped according to stenosis grade and used to create average representations. RESULTS: Accuracy and precision of the outlining technique were +/- 0.020 common carotid diameters (CCD) and +/- 0.025 CCD, respectively. Maximum narrowing of the internal carotid artery occurred at 0.3 CCD +/- 1.5 (mean +/- standard deviation) distal to the flow divider. The region of significant narrowing extended axially 1.2 CCD +/- 1.0. Poststenotic dilatations were observed, with enlargement of 1.3 +/- 0.7 times the normal diameter of the distal internal carotid artery. A tendency toward smaller bifurcation angles with increasing stenosis severity was observed. CONCLUSION: Three-dimensional geometric models could be created for carotid bifurcations that were disease free (normal) and of arbitrary stenosis grade.

Aged

MR gradient coil heat dissipation.

The temperature responses of five different gradient coil designs were modeled using simplified engineering equations and measured. The model predicts that the coil temperature approaches a maximum as an inverse exponential, where the maximum temperature is governed by two parameters: a local power density and a cooling term. The power density term is a function of position and is highest where the current paths have minimum widths and are closely packed. The cooling parameter consists of convective, conductive, and radiative components which can be controlled by (1) providing forced cooling, (2) having a coil former with high thermal conductivity and thin walls, and (3) varying the emissivity of the coil surfaces. For a given gradient strength, the average temperature rise is minimized by designing a coil with a small radius and thick copper. The model predicted the local temperature rise, which is also dependent on the current density, to within 5 degrees C of measured values.

Equipment Design

Measurement of fluid-shear rate by Fourier-encoded velocity imaging.

A new technique for estimating the blood fluid shear rate at the vessel wall is presented. The technique uses Fourier-encoded velocity imaging to determine the velocity distribution within a spatial element (voxel) that straddles the blood-vessel wall interface. By appropriate processing, the velocity distribution (1) can determine the location of the wall-blood interface within the voxel and (2) estimate the velocity profile across the spatial extent of the voxel. From this information, accurate estimates of fluid shear rate may be obtained. Simulations are presented to illustrate this technique and to show the effects of various error sources, including differences in proton densities between blood and wall tissues and flow-related signal changes. Experimental evidence obtained for steady flow in straight tubes is also presented in support of the technique. The mean error in the experimental shear rate estimates found using the proposed technique was -15%. This represents a significant improvement over estimates obtained by extrapolation of the velocity profile over multiple voxels (mean error of -73%).

Blood Flow Velocity

A novel transverse gradient coil design for high-resolution MR imaging.

The authors describe a new gradient coil design for high resolution human, animal, specimen, or phantom imaging with high gradient efficiency and a large region of excellent gradient uniformity. Important features of our new design are the simple analytical description of the wire patterns that comprise the design, and ease of construction. Wires are spaced in a sinusoidal distribution around the circumference of the cylinder, and curved in an arcsin shape along the length of the cylinder. This coil produces a magnetic field pointing in a direction transverse to the axis of the coil with a gradient in the direction parallel to the axis of the coil. The same arcsin coil can be used to create a magnetic field pointing in a direction parallel to its axis with a gradient in a direction perpendicular to the coil axis. A prototype coil was constructed; field and inductance calculations were verified. Geometric variations on this coil design were modeled and their performance characteristics compared. This coil design is ideal for rapid implementation of a transverse gradient coil, since no specialized design software is required.

Algorithms

Novel low-dosage hormonal replacement therapy complements dietary treatment of moderately hypercholesterolemic postmenopausal women.

It is not known whether female hormonal replacement therapy (HRT) influences fasting plasma lipoprotein lipids in diet-treated hypercholesterolemic subjects. Thirteen moderately hypercholesterolemic postmenopausal women were studied during dietary treatment alone with a low fat, low cholesterol diet for the 3 months and during the subsequent 2 y of HRT with dl-norgestrel (0.075 mg daily) and estradiol-17 beta (1 mg, 25 of 28 days) with maintenance of the same diet. Hormonal replacement therapy decreased plasma total cholesterol by 11 +/- 3% (5.7 vs. 6.4 mmol/L, p < 0.005), due to a 17 +/- 3% mean reduction (p < 0.001) in the concentration of plasma low density lipoprotein cholesterol (3.9 vs. 4.7 mmol/L, p < 0.001). The ratio of plasma total cholesterol to high density lipoprotein cholesterol fell significantly by 17 +/- 4% (4.1 vs. 4.9, p < 0.005). Mean fasting plasma concentrations of total triglycerides (1.1 vs. 1.6 mmol/L, p < 0.005) fell by 31 +/- 6%, and very low density lipoprotein triglycerides (0.56 vs. 0.83 mmol/L, p < 0.02) by 33 +/- 9%. Hormonal replacement therapy was well-tolerated, improved mood levels, and increased the mineral content of the vertebral spine significantly, while effectively relieving vasomotor flushing. Hormonal replacement therapy complements the dietary treatment of hypercholesterolemia.

Affect

Quadrupole gradient coil design and optimization: a printed circuit board approach.

Three different dual-axis quadrupole gradient coils for quantitative high resolution MR imaging of small animals, phantoms and specimens were designed and built using printed circuit board technology. Numerical optimization of the conductor positions was used to increase the volume of 0.4% gradient uniformity by up to a factor of four. In one coil, the volume of 5% gradient uniformity occupied 88% and 83% of the overall diameter and length of the coil, respectively. A systematic error of 0.5% in the wire placement was shown to cause a reduction in the volume of 0.4% gradient uniformity by a factor of two, though the region of 5% gradient uniformity was not significantly affected. Heat transfer calculations were used to determine maximum peak and root-mean-squared currents that could safely be applied to the coils.

Copper

Turbine flow sensor for volume-flow rate verification in MR.

A turbine flow sensor for MR flow experiments has been evaluated using reference volume-flow rate measurements obtained using an electromagnetic (EM) flow meter measurements and simultaneous phase contrast (PC) MR acquisitions. After calibration, the device was found to have accuracy (compared with the EM flow meter), linearity, and precision of better than +/- 1%, +/- 3.5%, 3.5%, respectively, in constant flow mode (0 to 30 ml s-1). The frequency response of the flow sensor was flat (within +/- 10%) up to 13.9 Hz. Volume-flow rate measurements on constant and simulated physiologic flow waveforms were in close agreement with both the electromagnetic (EM) flow meter and the gated MR PC estimates.

Calibration

Poster production by color laser imager.

The scientific poster is an important educational tool at most radiology meetings. The visual impact of the exhibit is important in attracting attention and conveying content to the reader. A new method of designing and producing full-color transilluminated posters in the radiology department using a personal computer and color laser imager is described. The advantages of this approach are author control over the production process and production of a visually interesting exhibit.

Audiovisual Aids

Generalized K-space analysis and correction of motion effects in MR imaging.

A new approach to understanding and reducing motion artifacts in magnetic resonance imaging (MRI) is introduced. This paper presents a novel technique for correcting generalized motion artifacts arising from translation, rotation, dilation, and compression, or any combination thereof. We also describe a new pulse sequence and a specialized postprocessing technique required to suppress these motion artifacts. The correction algorithm corrects for generalized motion. The theoretical basis of the correction scheme is founded upon the (k,t)-space formalism and the concept of pulse sequence contrast mapping functions. The proposed (k,t) formalism is based on the Fourier projection slice theorem and allows us to determine how motion artifacts arise. The correction technique currently suffers from some spatial resolution and signal-to-noise ratio limitations, and works better for small objects than large objects. These problems will be investigated in subsequent studies.

Artifacts

Fast Fourier projection for MR angiography.

We have developed a technique called fast Fourier projection which rapidly produces projections through images and is particularly useful for generating MR angiograms. Based on the projection-slice theorem of Fourier transform theory, this method extracts planes from three-dimensional spatial frequency space and computes projections at arbitrary viewing angles by two-dimensional inverse Fourier transformation. Typical computation times are on the order of 1 s per projection. This performance makes possible interactive selection of optimal projection directions for visualizing the desired vasculature in single or stereo-pair angiographic images and drastically reduces the time required to generate sequences of projections for display in movie loops compared to the conventional ray-casting approach. The method is easily implemented on off-line workstations or directly on MRI computer systems.

Angiography

Magnetic resonance techniques for blood-flow measurement and vascular imaging.

The authors review the history and physical principles behind vascular magnetic resonance imaging (MRI) techniques, developed to measure blood flow noninvasively and to display images of the vasculature. All these techniques have been used to create magnetic resonance angiograms, in which the vasculature is shown in a projection format similar to x-ray angiography. Signal loss limits the effectiveness of "white-blood" magnetic resonance angiography techniques, since slow flow and complex flow often cause a drop in signal and consequently a loss of accuracy in depicting vessel anatomy. "Black-blood" magnetic resonance angiography is described as a method that avoids these problems of signal loss. Selective black-blood magnetic resonance angiography is introduced as a technique for improving the visualization of the vasculature when other signal-void structures are present in the volume of interest.

Blood