Search PubMed⌕ Search

Biomedical subjects

B J Trask

Publications and source records attributed to B J Trask.

76 records · Page 5Linked to original sources

High-speed chromosome sorting.

Dual-beam high-speed sorting has been developed to facilitate purification of chromosomes based on DNA staining with the fluorescent dyes Hoechst 33258 and chromomycin A3. Approximately 200 chromosomes per second of two types can be sorted from a suspension of chromosomes isolated from human lymphoblasts while fluorescent objects (chromosomes, debris fragments, chromosome clumps, and nuclei) are processed at the rate of about 20,000 per second. This sorting rate is approximately ten times that possible with conventional sorters. Chromosomes of a single type can be sorted with a purity of about 90 percent. DNA from the sorted chromosomes is suitable for construction of recombinant DNA libraries and for gene mapping.

Animals↗

The binding kinetics and interaction of DNA fluorochromes used in the analysis of nuclei and chromosomes by flow cytometry.

The interactions and binding characteristics of DNA dyes used in the flow cytometric analysis of chromatin were studied using human chromosomes and mouse thymocyte nuclei. The kinetics of dye binding and the relationship between fluorescence intensity and dye concentration are presented. Under the conditions used, Hoechst 33258, propidium iodide and chromomycin A3 reach an equilibrium with thymocyte nuclei after approximately 5 min, 20 min and more than 1 h, respectively. The same binding kinetics are observed with Hoechst 33258 and chromomycin when nuclei are stained with a mixture of the two dyes. Sodium citrate, which improves the resolution of flow karyotypes, causes a rapid increase in Hoechst and propidium iodide fluorescence, but a decrease in the fluorescence of chromomycin. The relative peak positions of chromosomes in a flow karyotype are unaffected by sodium citrate addition. The spectral interaction between Hoechst and chromomycin is quantified. There is variation among the human chromosome types in the amount of energy transferred from Hoechst to chromomycin. By measuring the Hoechst and chromomycin fluorescence of each chromosome after Hoechst excitation, it is shown that the amount of energy transferred is correlated to the ratio of the amount of Hoechst to chromomycin bound. Although the energy transfer between the two dyes is considerable, this has little effect on the reproducibility of flow karyotype measurements. The relative peak positions of all human chromosomes in a 64 X 64 channel flow karyotype, except for the 13 and Y chromosomes, vary in the order of 0.5 channel over a 16-fold change in either Hoechst or chromomycin concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Preparation and bivariate analysis of suspensions of human chromosomes.

Chromosomes were isolated from a variety of human cell types using a HEPES-buffered hypotonic solution (pH 8.0) containing KCl, MgSO4, dithioerythritol, and RNase. The chromosomes isolated by this procedure could be stained with a variety of fluorescent stains including propidium iodide, chromomycin A3, and Hoechst 33258. Addition of sodium citrate to the stained chromosomes was found to improve the total fluorescence resolution. High-quality bivariate Hoechst vs. chromomycin fluorescence distributions were obtained for chromosomes isolated from a human fibroblast cell strain, a human colon carcinoma cell line, and human peripheral blood lymphocyte cultures. Good flow karyotypes were also obtained from primary amniotic cell cultures. The Hoechst vs. chromomycin flow karyotypes of a given cell line, made at different times and at dye concentrations varying over fourfold ranges, show little variation in the relative peak positions of the chromosomes. The size of the DNA in chromosomes isolated using this procedure ranges from 20 to over 50 kilobases. The described isolation procedure is simple, it yields high-quality flow karyotypes, and it can be used to prepare chromosomes from clinical samples.

Bisbenzimidazole↗

Analysis of phytoplankton by flow cytometry.

Optical properties of eight algae species were measured on a flow cytometer. Forward and perpendicular light scatter measurements provide information on the size and shape of algae cells. The intensity of chlorophyll fluorescence varies greatly among the studied algae species and can be used to distinguish them. Measurements of chlorophyll fluorescence after excitation with different wavelengths provide a fluorescence excitation spectrum for each species over the available wavelength range. These spectra reflect the different photosynthetic pigment contents of the species. Staining algae cells with the DNA stains, Hoechst 33342 and DAPI, provides two additional optical parameters to distinguish algae populations: blue nuclear fluorescence and yellow granular fluorescence. The combination of these optical measurements enables the distinction of each algae species into a small cluster in a hyperspace of parameters. The automation of phytoplankton analysis on the flow cytometer may lead to the rapid and objective assessment of water quality.

Chlorophyll↗