Search PubMed⌕ Search

Biomedical subjects

B J Lewis

Publications and source records attributed to B J Lewis.

At least 19 recordsLinked to original sources

LET dependence of bubble detector response to heavy ions.

A series of experiments have been recently performed at the Heavy Ion Medical Accelerator in Chiba (HIMAC) laboratory to study the response of bubble detectors to high-mass high-energy (HZE) particles. The motivation for this study was to improve our ability to interpret measurements of neutron energy spectra in space. A recent analysis showed that emulsions of light halocarbons display common properties when they are characterised by a quantity called 'reduced superheat'. This quantity evolved from the examination of neutron and gamma responses of many types of detectors. In this study, we describe direct irradiations with N, Ar and Kr charged particles at HIMAC. It was observed that when the linear energy transfer (LET) corresponding to bubble formation was plotted vs. reduced superheat, different curves were obtained for a particular ion for detectors at different temperatures. Different curves were also obtained when data from different ions were plotted. These results confirm that bubble nucleation is not a simple function of particle LET and that an analysis based on track-structure appears warranted.

Dose-Response Relationship, Radiation↗

Characterisation of bubble detectors for aircrew and space radiation exposure.

The Earth's atmosphere acts as a natural radiation shield which protects terrestrial dwellers from the radiation environment encountered in space. In general, the intensity of this radiation field increases with distance from the ground owing to a decrease in the amount of atmospheric shielding. Neutrons form an important component of the radiation field to which the aircrew and spacecrew are exposed. In light of this, the neutron-sensitive bubble detector may be ideal as a portable personal dosemeter at jet altitudes and in space. This paper describes the ground-based characterisation of the bubble detector and the application of the bubble detector for the measurement of aircrew and spacecrew radiation exposure.

Astronauts↗

Determination of natural and depleted uranium in urine at the ppt level: an interlaboratory analytical exercise.

An analytical exercise was initiated in order to determine those procedures with the capability to measure total uranium and uranium (238U/235U) isotopic ratios in urine samples containing >0.02 microg U kg-1 urine. A host laboratory prepared six identical sets of twelve synthetic urine samples containing total uranium in the range of 25 to 770 ng U kg-1 urine and with 238U/235U isotopic ratios ranging from 138 (100% NU) to 215 (51% DU). Sets of samples were shipped to five testing laboratories (four based in Canada and one based in Europe). Each laboratory utilized one of the following analytical techniques: sector field inductively coupled plasma mass spectrometry (ICP-SF-MS), quadrupole inductively coupled plasma mass spectrometry (ICP-Q-MS), thermal ionization mass spectrometry (TIMS), and instrumental/delayed neutron activation analysis (I/DNAA), in their analyses.

Canada↗

Estimated neutron dose to embryo and foetus during commercial flight.

A study has been carried out to assess the radiation exposure from cosmic-ray neutrons to the embryo and foetus of pregnant aircrew and air travellers in consideration of the radiation exposure from cosmic-ray neutrons to the embryo and foetus. A Monte Carlo analysis was performed to determine the equivalent dose from neutrons to the brain and body of an embryo at 8 weeks and to the foetus at the 3, 6 and 9 month periods. Neutron fluence-to-absorbed dose conversion coefficients for the foetal brain and for the entire foetal body (isotropic irradiation geometry) have been determined at the four developmental stages. The equivalent dose rate to the foetus during commercial flights has been further evaluated considering the fluence-to-absorbed dose conversion coefficients, a neutron spectrum measured at an altitude of 11.3 km and an ICRP-92 radiation-weighting factor for neutrons. This study indicates that the foetus can exceed the annual dose limit of 1 mSv for the general public after, for example, 15 round trips on commercial trans-Atlantic flights.

Aircraft↗

Aircrew dosimetry using the Predictive Code for Aircrew Radiation Exposure (PCAIRE).

During 2003, a portable instrument suite was used to conduct cosmic radiation measurements on 49 jet-altitude flights, which brings the total number of in-flight measurements by this research group to over 160 flights since 1999. From previous measurements, correlations have been developed to allow for the interpolation of the dose-equivalent rate for any global position, altitude and date. The result was a Predictive Code for Aircrew Radiation Exposure (PCAIRE), which has since been improved. This version of the PCAIRE has been validated against the integral route dose measurements made at commercial aircraft altitudes during the 49 flights. On most flights, the code gave predictions that agreed to the measured data (within +/- 25%), providing confidence in the use of PCAIRE to predict aircrew exposure to galactic cosmic radiation. An empirical correlation, based on ground-level neutron monitoring data, has also been developed for the estimation of aircrew exposure from solar energetic particle (SEP) events. This model has been used to determine the significance of SEP exposure on a theoretical jet altitude flight during GLE 42.

Aerospace Medicine↗

Assessment of aircrew radiation exposure by further measurements and model development.

A methodology is presented for collecting and analysing exposure measurements from galactic cosmic radiation using a portable equipment suite and encapsulating these data into a semi-empirical model/Predictive Code for Aircrew Radiation Exposure (PCAIRE) for the assessment of aircrew radiation exposure on any flight over the solar cycle. The PCAIRE code has been validated against integral route dose measurements at commercial aircraft altitudes during experimental flights made by various research groups over the past 5 y with code predictions typically within +/-20% of the measured data. An empirical correlation, based on ground-level neutron monitoring data, is detailed further for estimation of aircrew exposure from solar particle events. The semi-empirical models have been applied to predict the annual and career exposure of a flight crew member using actual flight roster data, accounting for contributions from galactic radiation and several solar energetic-particle events over the period 1973-2002.

Aerospace Medicine↗

Dopamine receptor expression on human T- and B-lymphocytes, monocytes, neutrophils, eosinophils and NK cells: a flow cytometric study.

This study documents expression of dopamine (DA) receptors on leukocyte subpopulations using flow cytometric techniques to identify dopamine receptors with subtype-specific antibodies. Of the D1-like receptor family (D(1) and D(5)), only D(5) was detected, and of the D2-like receptor family (D(2), D(3) and D(4)), all dopamine receptors were detected. T-lymphocytes and monocytes had low expression of dopamine receptors, whereas neutrophils and eosinophils had moderate expression. B cells and NK cells had higher and more consistent expression. Dopamine receptors D(3) and D(5) were found in most individuals whereas D(2) and D(4) had more variable expression. D(1) was never found.

B-Lymphocytes↗

Galactic and solar radiation exposure to aircrew during a solar cycle.

An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of aircrew during a solar cycle. A semi-empirical model has been derived from these data to allow for the interpolation of the dose rate for any global position. The model has been extended to an altitude of up to 32 km with further measurements made on board aircraft and several balloon flights. The effects of changing solar modulation during the solar cycle are characterised by correlating the dose rate data to different solar potential models. Through integration of the dose-rate function over a great circle flight path or between given waypoints, a Predictive Code for Aircrew Radiation Exposure (PCAIRE) has been further developed for estimation of the route dose from galactic cosmic radiation exposure. This estimate is provided in units of ambient dose equivalent as well as effective dose, based on E/H x (10) scaling functions as determined from transport code calculations with LUIN and FLUKA. This experimentally based treatment has also been compared with the CARI-6 and EPCARD codes that are derived solely from theoretical transport calculations. Using TEPC measurements taken aboard the International Space Station, ground based neutron monitoring, GOES satellite data and transport code analysis, an empirical model has been further proposed for estimation of aircrew exposure during solar particle events. This model has been compared to results obtained during recent solar flare events.

Aerospace Medicine↗

An examination of uranium levels in Canadian forces personnel who served in the Gulf War and Kosovo.

A uranium bioassay program was conducted involving 103 active and retired Canadian Forces personnel. The total uranium concentrations in each of two 24-h urine collections were analyzed separately at independent commercial laboratories by inductively coupled plasma mass spectrometry (ICP-MS) and by instrumental neutron activation analysis (INAA). The mean and median concentrations were determined to be 4.5 ng L(-1) and 2.8 ng L(-1), respectively, from ICP-MS and 17 ng L(-1) and 15 ng L(-1), respectively, from INAA. The total uranium concentrations were sufficiently low so that isotopic (238U:235U ratio) assays could not be performed directly from urine samples. Isotopic assays were performed on hair samples from 19 of the veterans participating in the testing. The isotopic hair assays were scattered around the natural 238U:235U ratio of 137.8, ranging from 122 +/- 21 to 145 +/- 16 (1sigma). Due to concern expressed in the media over possible depleted uranium exposure and long-term retention in bone, a single bone sample (vertebrate bone marrow) from a deceased member of the Canadian Forces was also analyzed for total uranium content and isotopic ratio by ICP-MS. The sample was shown to have 16.0 +/- 0.3 microg kg(-1) uranium by dry weight and a 238U:238U isotopic ratio of 138 +/- 4, consistent with natural uranium.

Canada↗

Aircrew exposure from cosmic radiation on commercial airline routes.

As a result of the recent recommendations of the ICRP 60, and in anticipation of possible regulation on occupational exposure of Canadian-based aircrew, an extensive study was carried out by the Royal Military College of Canada over a one-year period to measure the cosmic radiation at commercial jet altitudes. A tissue-equivalent proportional counter was used to measure the ambient total dose equivalent rate on 62 flight routes, resulting in over 20,000 data points at one-minute intervals at various altitudes and geomagnetic latitudes (i.e. which span the full cut-off rigidity of the Earth's magnetic field). These data were then compared to similar experimental work at the Physikalisch Technische Bundesanstalt, using a different suite of equipment, to measure separately the low and high linear energy transfer components of the mixed radiation field, and to predictions with the LUIN transport code. All experimental and theoretical results were in excellent agreement. From these data, a semiempirical model was developed to allow for the interpolation of the dose rate for any global position, altitude and date (i.e. heliocentric potential). Through integration of the dose rate function over a great circle flight path, a computer code was developed to provide an estimate of the total dose equivalent on any route worldwide at any period in the solar cycle.

Aircraft↗

Assessment of the cosmic radiation exposure on Canadian-based routes.

As a result of the recent recommendations of the ICRP-60 and in anticipation of possible regulation on occupational exposure of commercial aircrew, a two-phase investigation was carried out over a 1-y period to determine the total dose equivalent on representative Canadian-based flight routes. In the first phase of the study, dedicated scientific flights on a Northern round-trip route between Ottawa and Resolute Bay provided the opportunity to characterize the complex mixed-radiation field and to intercompare various instrumentation using both a conventional suite of powered detectors and passive dosimetry. In the second phase, volunteer aircrew carried (passive) neutron bubble detectors during their routine flight duties. From these measurements, the total dose equivalent was derived for a given route with a knowledge of the neutron fraction as determined from the scientific flights and computer code (CARI-3C) calculations. This study has yielded an extensive database of over 3,100 measurements providing the total dose equivalent for 385 different routes. By folding in flight frequency information and the accumulated flight hours, the annual occupational exposures of 20 flight crew have been determined. This study has indicated that most Canadian-based domestic and international aircrew will exceed the proposed annual ICRP-60 public limit of 1 mSv y(-1) but will be well below the occupational limit of 20 mSv y(-1).

Aircraft↗

Cosmic radiation exposure on Canadian-based commercial airline routes.

As a result of the recent recommendations of ICRP 60 and in anticipation of possible regulation on occupational exposure of commercial aircrew, a two-part investigation was carried out over a one-year period to determine the total dose equivalent on representative Canadian-based flight routes. As part of the study, a dedicated scientific measurement flight (using both a conventional suite of powered detectors and passive dosimetry) was used to characterise the complex mixed radiation field and to intercompare the various instrumentation. In the other part of the study, volunteer aircrew carried (passive) neutron bubble detectors during their routine flight duties. From these measurements, the total dose equivalent was derived for a given route with a knowledge of the neutron fraction as determined from the scientific flight and computer code (CARI-LF) calculations. This investigation has yielded an extensive database of over 3100 measurements providing the total dose equivalent for 385 different routes. By folding in flight frequency information and the accumulated flight hours, the annual occupational exposures of 26 flight crew have also been determined. This study has indicated that most Canadian-based domestic and international aircrew will exceed the proposed annual ICRP 60 public limit of 1 mSv.y-1, but will he well below the occupational limit of 20 mSv.y-1.

Aerospace Medicine↗

Characterisation of neutron-sensitive bubble detectors for application in the measurement of jet aircrew exposure to natural background radiation.

A survey of the natural background dose equivalent received by Canadian Forces aircrew was conducted using neutron-sensitive bubble detectors (BDs) as the primary detection tool. Since this study was a new application for these detectors, the BD response to neutron dose equivalent (RD) was extended from thermal to 500 MeV in neutron energy. Based upon the extended RD, it was shown that the manufacturer's calibration can be scaled by 1.5 +/- 0.5 to give a BD sensitivity that takes into account recently recommended fluence-to-neutron dose equivalent conversion functions and the cosmogenic neutron spectrum encountered at jet altitudes. An investigation of the effects of systematic bias caused by the cabin environment (i.e., temperature, pressure and relative humidity) on the in-flight measurements was also conducted. Both simulated and actual aircraft climate tests indicated that the detectors are insensitive to the pressure and relative humidity variations encountered during routine jet aircraft operations. Long term conditioning tests also confirmed that the BD-PND model of detector is sensitive to variations in temperature to within +/- 20%. As part of the testing process, the in-flight measurements also demonstrated that the neutron dose equivalent is distributed uniformly throughout a Boeing 707 jet aircraft, indicating that both pilots and flight attendants are exposed to the same neutron field intensity to within experimental uncertainty.

Air Pressure↗

Alternating hepatic intra-arterial floxuridine and fluorouracil: a less toxic regimen for treatment of liver metastases from colorectal cancer.

Hepatic intra-arterial (HIA) infusion of floxuridine (FUDR) via an implanted pump has shown promise in the treatment of colorectal cancer metastasized to the liver. However, the potential benefit of this therapy may be offset by the high incidence of treatment-limiting biliary toxicity. Although weekly HIA bolus of fluorouracil (5-FU) is effective against metastatic colorectal cancer to the liver with no biliary toxicity, it is limited by systemic side effects. In December 1986, we began a phase II trial of alternating HIA FUDR and 5-FU via the implanted pump in an attempt to extend the duration of treatment by obviating the limiting biliary (FUDR) and systemic (5-FU) drug toxic effects. Patients received continuous HIA FUDR at 0.1 mg/kg of body weight per day on days 1 through 8 followed by an HIA bolus of 5-FU at 15 mg/kg given via the pump sideport on days 15, 22, and 29, with the cycle repeated every 35 days. Sixty-eight patients were enrolled in this trial, and 64 were fully evaluable. Of the 64 patients, 30 (47%) previously had received chemotherapy. Major response (complete response plus partial response) was observed in 32 (50%) of 64 patients, and the median survival from pump implantation in all patients was 22.4 months. In contrast to the experience with the single-agent HIA FUDR regimen, no patient had treatment terminated because of drug toxicity. Alternating HIA FUDR and 5-FU has efficacy similar to that of HIA FUDR given alone, but when closely monitored and adjusted appropriately, is not associated with toxic effects requiring treatment termination.

Antineoplastic Combined Chemotherapy Protocols↗

Chemoembolization for hepatocellular carcinoma.

Fifty-one patients with unresectable hepatocellular carcinoma (HCC) were treated with Gelfoam (absorbable gelatin sterile powder; The Upjohn Co, Kalamazoo, MI) chemoembolization. A mixture of Gelfoam powder, contrast media, and three drugs (doxorubicin, mitomycin, and cisplatin) was injected under fluoroscopic guidance via a percutaneous catheter into the hepatic artery until stagnation of blood flow was achieved. Of the 51 patients, 50 are assessable for response, and all are assessable for toxicity and complications. The median percent of liver replacement was 50% (range, 15% to 95%). By conventional response criteria, there were 12 partial responses (PRs) (24%), 13 minor responses (MRs) (26%), 12 stabilization of disease (SD) (24%), and 13 (26%) progressive disease (PD). Tumor liquefaction was noted on computed tomographic (CT) scan in 35 of 50 patients (70%). Of the 34 patients with elevated alpha-fetoprotein (AFP), 23 (68%) had a greater than 50% reduction following treatment. Responding patients were re-treated at the time of tumor progression if they still met the entry criteria. The median survival of assessable patients from the time of treatment was 207 days and from the diagnosis of the primary was 302 days. Fourteen patients remain alive at 3 months to 3 years following treatment. The vast majority of patients had transient pain, fever, nausea, and elevation in liver enzymes. Ascites developed in 14 patients. There were two treatment-related deaths: one from tumor hemorrhage and one from liver failure. Chemoembolization appears to have significant activity in patients with hepatocellular carcinoma and is relatively well tolerated.

Adolescent↗

A randomized trial of continuous intravenous versus hepatic intraarterial floxuridine in patients with colorectal cancer metastatic to the liver: the Northern California Oncology Group trial.

In 1983, the Northern California Oncology Group (NCOG) instituted a randomized trial of intravenous (IV) versus intraarterial (IA) floxuridine (FUDR) administered via an implantable pump for patients with colorectal cancer metastatic to the liver. The study objectives were to compare the hepatic response rate, time to hepatic progression, and toxicity for the two treatment arms. The study design, which allowed patients failing IV FUDR to crossover to the IA arm, prevents a meaningful comparative analysis of survival. Patients with liver-only metastases (N = 143) were randomized, 76 to the IV arm and 67 to the IA arm, and 115 patients (65 IV, 50 IA) were fully evaluable. Of the 65 patients in the IV arm, 28 crossed over to IA treatment after failing IV FUDR. The dose-limiting toxicity of IV FUDR was diarrhea, whereas biliary toxicity limited both the dose and duration of IA FUDR therapy. Of the first 25 patients treated with IA FUDR at a dose of .3 mg/kg/day, 10 developed radiographically evident biliary strictures, and three developed permanent jaundice. With reduction of the initial IA FUDR dose to .2 mg/kg/day, and adoption of a policy of early dosage reduction, treatment interruption, or termination of therapy for persistent elevations in alkaline phosphatase, only two further cases of serious biliary toxicity occurred. However, 26 of the 50 IA FUDR patients ultimately had therapy terminated because of drug toxicity rather than disease progression. When compared with systemic infusion, infusion into the hepatic artery greatly enhanced the antitumor activity of FUDR against colorectal liver metastases. Although biliary toxicity is the most serious limitation of this form of therapy, biliary stricture and jaundice usually can be averted through careful monitoring of liver enzymes and early dosage reduction.

Adult↗

Regional chemotherapy for colorectal cancer metastatic to the liver.

Regionally directed therapies, especially hepatic intra-arterial chemotherapy, have produced encouraging results against liver metastases from colorectal cancer. An implanted system allows treatment to be administered in the outpatient setting. Intra-arterial floxuridine has been shown to produce an increased response rate and prolonged time to progression of intrahepatic tumor compared to conventional treatment, but whether or not survival is prolonged has not yet been determined. Hepatobiliary toxicity from floxuridine limits the duration of therapy. Other experimental methods of regional therapy include chemoembolization, chemofiltration and mechanical alterations in hepatic arterial flow rate.

Antineoplastic Agents↗